continuous emissions monitoring Equipment in District of Columbia

60 Results found
  • Category: Air & Climate ×

  • Subcategory: Air Monitoring ×

  • Keyword: continuous emissions monitoring ×

  • Location: USA ×

  • Location: District of Columbia ×

PCME - Model STACK 980 - Particulate Continuous Emission Monitor

by PCME Ltd

The PCME STACK 980 is an approved Particulate Continuous Emission Monitor suited to industrial applications in stacks after bag filters, cartridge filters, cyclones and process driers. The instrument combines the latest regulatory approvals (MCERTS Performance Standards for Automated Dust Arrestment-Plant Monitors, version 1 (August 2010), class 2 ...

Model SM8200 - SO2/NO In Situ Multi-Gas Analyzer

by Teledyne Monitor Labs, Inc.

The transceiver houses the light source, spectrometer, multi-gas photodiode array detector system and various focusing optics for outstanding performance over a significant range of operating conditions.  The transceiver is constructed of a rugged cast aluminum housing which is latch-detachable from the probe assembly for easy removal and ...

Model VCEM5100 - Flue Gas Flow Monitor

by Codel International Ltd

Continuous on-line analysis often only considers the density of the emissions (e.g mg/Nm3) In order to obtain a measurement of total emissions for pollution monitoring (e.g kg/hr) it is necessary to either calculate or measure flow within the gas stream. The VCEM5100 provides non-contact measurement of gas velocity using a time-delay correlation ...

Model VCEM5000 - Flue Gas Flow Monitor

by Codel International Ltd

Continuous emission monitoring often only considers the density of the emissions (e.g mg/Nm3) In order to obtain a measurement of total emissions for pollution monitoring (e.g kg/hr) it is necessary to either calculate or measure flow within the gas stream. The VCEM5000 provides non-contact measurement of gas velocity using a time-delay ...

StackGuard - Dust Emission Measuring System

by Sigrist-Photometer AG

The StackGuard continuously monitors the scatted light intensity of an extracted, withdrawn sample of gas. The laser light source minimized stray light and improves sensitivity to the µg/m³ level, the filtered purge air prevents from window soiling. A calibration check is performed by means of a checking rod. The sample air is led out ...

Model AL4021 Series - Continuous Formaldehyde in Air and Water Monitor

by AERO-LASER GmbH

Automated HCHO analyzer for very low concentrations.The AL4021 is a completely automated and continuously working formaldehyde (HCHO) analyzer for gaseous and liquid samples based on the Hantzsch reaction, which is sensitive to very low concentrations of HCHO (ppbV for gaseous samples and µg/l for liquid samples). All functions of the AL4021 ...

IntelliCEMS - Model IC Series - Straight Extraction Or Dilution Extraction Systems

by Cemtrex Inc.

The IC Series IntelliCEMSTM include straight extraction or dilution extraction systems complete with sample probes, heated sample bundles, sampling systems, analyzers, and Data Acquisition Systems (DAS). Our CEMS are pre-engineered and packaged to measure a wide range of gases and pollutants for compliance with state and federal EPA regulations ...


PCME - Model STACK 181 WS - Particulate Measurement Systems

by PCME Ltd

The PCME STACK 181 WS is suitable for measuring particulate emissions from wet scrubbers and other processes where the flue gas falls below dew point (cold stack conditions) or water droplets are present. The extractive instrument takes a representative continuous sample from the stack, heats this well above dew point to evaporate water droplets ...

Lowe Engineering - Gas Sample / Detection Analysis

by Lowe Engineering Limited

The following extract from Perry's Chemical Engineers' Handbook, will give some insight into the sampling and analysis of Hydrocarbons.

MRU - Model SWG 300-1 - Emission Monitoring Systems

by MRU Instruments, Inc.

CEMS based on cold&dry extractive technolgy. Using complete gas sample conditioning system (heated probe filter, heated sampling line, gas cooler etc) and NDIR or GFCIR measurement for up to 6 flue gas components (O2, CO, CO2 , NO, SO2, HC). Also suitable for installations in hazardous area zone 2 (class 1, div 2), with manufacturer ...

Need help finding the right suppliers?

Let the XPRTs do the work for you