Tekran - Model 2537X - Automated Ambient Air Analyzer

by Tekran Instruments Corporation     based in Knoxville, TENNESSEE (USA)

The Tekran 2537 performs continuous long-term, unattended analysis of gaseous elemental mercury with unmatched accuracy, sensitivity, and reliability. The Tekran 2537 is easy to setup, use, and maintain and has long been known for its stable performance in rugged conditions. Our instruments have been installed at both Polar Regions, on ocean ...

Model MP101M (CPM option) - Ambient Suspended Particulates Analyzer

by Environnement S.A     based in Poissy, FRANCE

The standard Beta gauge measurement Method ISO 10473 of the MP101M analyzer allows, whenused with the patented optical technology of the CPM module, the continuous and simultaneousmeasurement of fine dust.The instrument is compliant with the European Standards EN 12341 for PM10, EN 14907for PM2.5 and was approved as a designated Federal Equivalent ...

PQ200 - Ambient Fine Particulate Sampler

by Keika Ventures, LLC (KV)     based in Chapel Hill, NORTH CAROLINA (USA)

BGI Incorporated produces the PQ200 Ambient PM2.5 Federal Reference Method (FRM) and FRM 'Portable Audit' Sampling Systems. The PQ200 is designed to meet exacting criteria for collecting 24-hour samples of ambient 'Fine Particulate,' according to the U.S. National Ambient Air Quality Standards (NAAQS), published July 18, 1997. BGI has developed ...

Tekran - Model 1120 - Standard Addition Controller

by Tekran Instruments Corporation     based in Knoxville, TENNESSEE (USA)

The Tekran Model 1120 Standard Addition Controller allows standard additions of elemental mercury into ambient air while using the Model 2537 Mercury Vapour Monitor. It is a valuable quality assurance tool that provides positive indication that the analyzer is operating properly. The Tekran 1120 is now offered as a firmware plugin for the 2537X.

frmOMNI - Ambient Air Sampler (Filter Reference Method)

by Keika Ventures, LLC (KV)     based in Chapel Hill, NORTH CAROLINA (USA)

Saturation monitoring has generally been accomplished at low flow rates in order to keep the cost and weight of the equipment down. BGI has brought this approach to its ultimate development with the addition of a true 5 lpm inlet. The US Environmental Protection Agency (EPA) encourages state and local air monitoring groups to conduct short-term ...

Model PQ167HA - High Altitude Ambient Particulate Sampler and High Altitude Calibrator

by Keika Ventures, LLC (KV)     based in Chapel Hill, NORTH CAROLINA (USA)

Through BGI’s continuing advances in the design of new inlets and cyclones, we are proud to offer a new sampler as a solution to the historical problem of high altitude sampling. BGI offers the model PQ167HA as an EPA type platform sampler that operates at a controlled flow rate of 5 LPM at elevations up to 15,000 feet (4,572 meters). The ...

Model FH 62 C14 - Continuous Particulate Monitor

by Thermo Scientific - Air Quality Instruments     based in Franklin, MASSACHUSETTS (USA)

Advanced FH62 systems provide continuous automatic, real-time ambinet particulate measurement and are ideal for air quality measurement and for air quality networks. They can be configured for TSP, PM10, and PM2.5 sampling. Extremely accurate and insensitive to vibration, they are the only beta gauges with a truely continuous 60-minute to ...

Model 5012 - Multi Angle Absorption Photometer

by Thermo Scientific - Air Quality Instruments     based in Franklin, MASSACHUSETTS (USA)

The Model 5012 MAAP measures the aerosol-related absorption of light and the corresponding atmospheric black carbon mass concentration. Continuous data is provided by a multiple detector setup to simultaneously measure the transmitted and the scattered light from a particle-loaded filter. Typical applications include determining ambient ...

Model 2000 - Partisol FRM

by Thermo Scientific - Air Quality Instruments     based in Franklin, MASSACHUSETTS (USA)

The Partisol-FRM Model 2000 Air Sampler is USEPA reference method designated for both PM-2.5 and PM-10. It is the proven manual sampling platform for the USEPA PM-2.5 standard. It is based upon the original Partisol Air Sampler, which received the USEPA reference designation for PM-10 measurements in June 1994.

Dichotomous - Model PM10/2.5 - Sampler

by Thermo Scientific - Air Quality Instruments     based in Franklin, MASSACHUSETTS (USA)

The manual dichotomous sampler is used for routine compliance montoring for PM10 and PM2.5. The Dichotomous sampler operates at a flow rate of 1 CHM (16.7 LPM) and is available with built-in mechanical 6-day or 7-day times, or an electronic digital programmable timer.