Model 24257 - SP-2331 Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 30 m × 0.25 mm, df 0.20 μm (Supelco)Application: A highly polar cyanosiloxane column specially tested for analyses of dioxins, specifically tetrachlorodibenzodioxin (TCDD) isomers. Because the phase is stabilized, it has a maximum temperature slightly higher than non-bonded cyanosiloxane columnsUSP Code: nonePhase:• Stabilized • ...

Model 24104-U - SP-2331 Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 60 m × 0.25 mm, df 0.20 μmApplication: A highly polar cyanosiloxane column specially tested for analyses of dioxins, specifically tetrachlorodibenzodioxin (TCDD) isomers. Because the phase is stabilized, it has a maximum temperature slightly higher than non-bonded cyanosiloxane columnsUSP Code: nonePhase:• Stabilized • Proprietary Te

Model 24105-U - SP-2331 Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 60 m × 0.32 mm, df 0.20 μmApplication: A highly polar cyanosiloxane column specially tested for analyses of dioxins, specifically tetrachlorodibenzodioxin (TCDD) isomers. Because the phase is stabilized, it has a maximum temperature slightly higher than non-bonded cyanosiloxane columnsUSP Code: nonePhase:• Stabilized • Proprietary Te

AMESA - Dioxin/Furan Monitoring System

by Environnement S.A     based in Poissy, FRANCE

Continuous dioxin/furan emission monitoring by long-term sampling. The only long-term sampling system for dioxins with TÜV, MCERT and ETV EPA approvals.

AMESA - Dioxin Emissions Monitoring

by Environnement S.A     based in Poissy, FRANCE

Dioxin emissions. Monitoring of dioxins. Amesa Dioxin Monitoring System

Model 28532-U - SLB-5ms Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 30 m × 0.32 mm, df 0.32 μmApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, ...

Model 28484-U - SLB-5ms Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 30 m × 0.32 mm, df 0.50 μmApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, ...

Model 28487-U - SLB-5ms Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 30 m × 0.32 mm, df 1.00 μmApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, ...

Model 28541-U - SLB-5ms Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 30 m × 0.53 mm, df 0.50 μm Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, ...

Model 28559-U - SLB-5ms Capillary GC Column

by Sigma-Aldrich/Supelco     based in Bellefonte, PENNSYLVANIA (USA)

L × I.D. 30 m × 0.53 mm, df 1.00 μmApplication: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, ...