Topics

Sections

atmospheric monitoring Equipment in Equatorial Guinea

18 Results found
Order by:
Recommended | 
Alphabetical

Integrating Nephelometer

by TSI Incorporated

Integrating Nephelometers are analytical instruments useful for short-or long-term measurements of the light-scattering coefficient of atmospheric and laboratory aerosols. They are particularly well-suited for measurements related to climate, visibility, and air quality. These unique instruments offer sensitivity to aerosol-scattering coefficients ...

HORIBA - APNA-370 - Ambient NOx Monitor

by HORIBA Europe GmbH

The APNA-370 continuously monitors atmospheric NOX, NO2, and NO concentrations using a cross-flow modulated semi decompression chemiluminescence method. The APNA-370 employs an independent, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy. The dry method, due to its minimal maintenance requirements and ...

APSA-370 - Ambient Sulfur Dioxide Monitor

by HORIBA Europe GmbH

The APSA-370 is a device for the continuous monitoring of atmospheric SO2 using UV fluorescence. The APSA-370 employs an proprietary, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy. The dry-method, due to its minimal maintenance requirements capability of continuous monitoring and instantaneous ...

HORIBA - APOA-370 - Ambient Ozone Monitor

by HORIBA Europe GmbH

The APOA-370 continuously monitors atmospheric ozone concentrations using a cross flow modulated ultraviolet absorption method. The APOA-370 employs an independent, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy. The dry method, due to its minimal maintenance requirements and capability of ...

HORIBA - APHA-370 - Ambient THC monitor

by HORIBA Europe GmbH

The APHA-370 continuously monitors atmospheric THC, NMHC, and CH4 concentrations using a cross-flow modulated selective combustion type method combined with a hydrogen ion detection method. The APHA-370 employs an independent, internal dry-method sampling device to achieve the highest levels of sensitivity and accuracy.

Airmodus A20 Butanol Condensation Particle Counter

by Enviro Technology Services plc

The Airmodus bCPC can be used both as stand-alone instrument for measuring the total particle number concentration, and as counter in different kinds of aerosol measurement applications. It is specifically designed to be easy to use and handle. All settings can be quickly adjusted from a handy touch screen, which also displays the current ...

Fog Sentry

by Climatronics Corporation

The Fog Sentry™ is an infrared, forward scatter sensor that builds on the findings of years of visibility sensor testing by the National Weather Service and Federal Aviation Administration. Technical papers published by these organizations state the need for a 42 degree scatter angle for optimal performance in fog and snow as well as downward ...

Tekran - Model 2537X - Automated Ambient Air Analyzer

by Tekran Instruments Corporation

The Tekran 2537 performs continuous long-term, unattended analysis of gaseous elemental mercury with unmatched accuracy, sensitivity, and reliability. The Tekran 2537 is easy to setup, use, and maintain and has long been known for its stable performance in rugged conditions. Our instruments have been installed at both Polar Regions, on ocean ...

Barometers

by LSI-LASTEM srl

Barometers are sensors for measuring atmospheric pressure.The CX110P and CX115P models are destined for applications with connections to measurement systems (recorders, data loggers, etc.) that accept analog signals; instead, the CX111P model is prevalently destined for use with LASTEM’s BabucABC data loggers. The barometers function according to ...

FW05 Type E Fine Wire TC, 0.0005

by Campbell Scientific, Inc.

The FW05 Fine Wire Thermocouple is typically used to measure atmospheric temperature gradients or fluctuations. The small mass of the thermocouples is less susceptible to solar loading; therefore, a radiation shield is not required. One differential analog input per sensor is required.


Air & ClimateEnergy & RenewablesEnvironmental ManagementHealth & SafetyMonitoring & TestingSoil & GroundwaterWaste & RecyclingWater & Wastewater