ozone analyzers Equipment in Congo, Democratic Republic of the

42 Results found
  • Category: Monitoring & Testing ×

  • Subcategory: Air Monitoring ×

  • Keyword: ozone analyzers ×

  • Location: Africa ×

  • Location: Congo, Democratic Republic of the ×

Serinus - Model 10 - Ozone Analyzer

by Ecotech Pty Ltd     based in Knoxfield, AUSTRALIA

The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air.

Ecotech - VOC Analyzer

by Ecotech Pty Ltd     based in Knoxfield, AUSTRALIA

Volatile organic compounds are an ill defined group of hydrocarbons, VOCs, result from burning of coal, oil and gasoline. These and other sources, including solvents, cleaners and paints, all contribute to the baseline level of different VOCs found in ambient air. VOCs are of interest because they photo-chemically react (in sunlight) to cause ...

BMT - Model 964 C - Ozone Analyzers

by BMT Messtechnik GmbH     based in Stahnsdorf, GERMANY

Cabinet version of ozone analyzer (wall-mount metal cabinet, splash-proof) in Vent configuration, with internal purge unit (with binary output programmed as purge timer), flow meter, squeeze valve (throttle valve), sample gas filter, catalyzing cartridge.DT25: dirt trap 25ml, attached BMT 964 C PRESS: High pressure version without Catalyzing ...

CAPS NO2 analyzer - Model AS32M - US EPA & TÜV certified

by Environnement S.A     based in Poissy, FRANCE

• Precise and continuous NO2 monitoring (0-1 ppm)• Direct sample measurement - no chemical conversion required, no need for a convertor, ozone generator, external pump, scrubber and no Toxic Gas Emission• Very short response time: capable of detecting short events with high precision• Innovative, patented Cavity Attenuated Phase Shift ...

Enviro - Model 600 Series - Chemiluminescent NO/NOx Digital Analyzer

by Enviro Technology Services plc     based in Stroud, UNITED KINGDOM

The California Analytical Instruments Model 600 CLD NO/NOx digital analyser is designed around a state-of-the-art 16-bit microprocessor. The 16 bit microprocessor control board consists of the MSR-Card with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyser can be manually operated from the keypad or ...

TAPI - Model 200EU NOy - Chemiluminescence NO-NOy Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

Teledyne – API remains in the forefront of ozone precursor research with the Model 200EU NOy Analyzer. This analyzer utilizes the chemiluminescence effect to measure Total Reactive Oxides of Nitrogen as part of a comprehensive ozone precursor monitoring program.

TAPI - Model T265 - Chemiluminescence O3 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The innovative T265 is an ultra-high precision ozone analyzer, based on the chemiluminescence of ozone combined with nitric oxide (NO). The T265 is safe, stable, and virtually free from interferences. It is ideal in applications where the photometric method may have false-positive indications from fine particulates, Hg, turpines, ClO2, and VOCs. ...

TAPI - Model 265E - Chemiluminescence O3 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model 265E used the proven chemiluminescence detection principle, coupled with state of the art microprocessor technology to provide the sensitivity, stability, and ease of use needed for ground level ambient Ozone monitoring requirements.

Model T703 - Photometric O3 Calibrator

by Enviro Technology Services plc     based in Stroud, UNITED KINGDOM

The Model T703 is a microprocessor controlled ozone calibrator for precision gas analysers. It can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM. The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and ...

Need help finding the right suppliers?

Let the XPRTs do the work for you