Sierra CalTrak - Model 500 - Modular Gas Flow Calibrator

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Sierra's CalTrak 500 is a high-accuracy, modular primary standard gas flow calibrator for all inert gases. Fast and portable, the 500 offers standardized accuracy of ±0.35% for customers who have many flow instruments to be validated or calibrated frequently. Primarily used for standard calibration and ...

CalTrak - Model 800 - Gas Mass Flow Standard

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

The CalTrak® 800 is the most accurate commercially available portable primary gas flow standard. The 800 brings world-class accuracy to your flow lab with a standardized accuracy of ±0.15% of reading, superior to all other commercial laboratory standards. Primarily used for standard calibration and verification of mass flow meters, ...

Dynacalibrator - Model 150 - Calibration Gas Generators

by VICI Metronics     based in Poulsbo, WASHINGTON (USA)

At only 6' wide x 15' deep x 7' high and 10.5 pounds, the Dynacalibrator 150 is a compact, full-featured calibrator capable of delivering the precise concentrations you require. A passivated glass-coated permeation chamber houses the permeation device(s), with measured inert carrier gas sweeping the calibration gas/vapor from the chamber. The ...

Dynacalibrator - Model 230 - Calibration Gas Generators

by VICI Metronics     based in Poulsbo, WASHINGTON (USA)

With a flexible flow metering system to maintain a constant carrier flow through the permeation chamber, the Model 230 allows the dilution flow to be varied over a wide range, generating the spectrum of concentrations required for checking analyzer linearity. Like all Dynacalibrators, its large permeation chamber is big enough to accomodate ...

Dynacalibrator - Model 340 - Calibration Gas Generators

by VICI Metronics     based in Poulsbo, WASHINGTON (USA)

The Model 340 adds a front panel mode control switch to select among zero, span, or remote calibration modes. In the zero mode, scrubbed air is delivered to the stream outlet. In the remote mode, the Model 340 can be externally programmed to deliver a zero and a span reference on command.

Dynacalibrator - Model 450 - Calibration Gas Generators

by VICI Metronics     based in Poulsbo, WASHINGTON (USA)

Ordinarily, the plumbing connections between the sample manifold, analyzer, and calibrator must be changed for each calibration. The Model 450’s unique “through-port” feature eliminates this chore. The mode control switch selects among standby, zero, span 1 (low concentration), span 2 (high concentration), and remote modes. In ...

Dynacalibrator - Model 500 - Calibration Gas Generators

by VICI Metronics     based in Poulsbo, WASHINGTON (USA)

This innovative design features two separate permeation chambers with independent temperature control systems. The chambers can be used independently, or together to combine concentrations of trace components. Separate solenoid valves allow the carrier flows to be switched from the dilution flow to a vent port.

Model 408 Series - Nitric Oxide Calibration Source

by 2B Technologies     based in Boulder, COLORADO (USA)

The Model 408 Nitric Oxide Calibration Source is a portable source of nitric oxide that allows one to calibrate any nitric oxide monitor.  The instrument scrubs NO from ambient air and produces either zero air or air having a mixing ratio of NO in the range 10-1,000 parts-per-billion by volume (ppbv).  The desired NO concentration is ...

Model CAL291 - Precision Acoustic Calibrator

by Larson Davis, a division of PCB Piezotronics     based in Depew, NEW YORK (USA)

The Model CAL291 is a dual channel Sound Calibrator. It is designed for measuring the residual intensity of sound intensity measurement systems. The following specifications apply: - When used with external signal generators the CAL291 Calibrator shall produce matched dual channel outputs of: ٠Sinusoids; Pink/White BB Noise. ٠1/3 ...

Landcal - Model R1500T - High Temperature Transport

by Land Instruments International     based in Dronfield, UNITED KINGDOM

High Temp. Transportable blackbody reference source. LANDCAL R1500T is a high temperature, transportable blackbody radiation source designed for calibration of a range of thermometers such as System 4 and Fibroptic thermometers. R1500T is a reference standard source giving a resolution of ±1°C/2°F.

Need help finding the right suppliers?

Let the XPRTs do the work for you