stack sampling Equipment in Djibouti

Served | Office inNear
85 Results found
  • Category: Monitoring & Testing ×

  • Subcategory: Environmental Sampling ×

  • Keyword: stack sampling ×

  • Location: Africa ×

  • Location: Djibouti ×

HI-Q - Gas Sampling & ISO-Kinetic Sampling Probes

by HI-Q Environmental Products Company     based in San Diego, CALIFORNIA (USA)

HI-Q Environmental Products Company's product line includes complete stack sampling systems, consisting of a specified type of probe, in-line filter holder, the transport line, sampling pump and flow controller. We recommend, design, and supply complete systems. HI-Q Environmental Products Company is able to make stack-sampling systems design ...

HI-Q - Stack Sampling System Design

by HI-Q Environmental Products Company     based in San Diego, CALIFORNIA (USA)

HI-Q is ready to help with your stack sampling requirements: State and Federal nuclear regulatory agencies require a stack discharge sampling program as part of the licensing process. Radionuclides discharged to the air in the form of particulate and volatile compounds must be assayed. Therefore, nuclear facilities are required to follow standard ...

Sampling System

by EcoChem Analytics     based in League City, TEXAS (USA)

In order for a Continuous Emission Monitoring System (CEMS) to function as desired it must be configured to deal with the environment and source type it will operate in. The rude fact is that the application engineering aspect of CEMS may be the most important part and it is in sampling systems where that is most critical. But it is not easy, ...

PCME - Model STACK 181 WS - Particulate Measurement Systems

by PCME Ltd     based in St Ives, UNITED KINGDOM

The PCME STACK 181 WS is suitable for measuring particulate emissions from wet scrubbers and other processes where the flue gas falls below dew point (cold stack conditions) or water droplets are present. The extractive instrument takes a representative continuous sample from the stack, heats this well above dew point to evaporate water droplets ...

PACE - Model 1410 - Heated Stack Filter Box

by PACE Environmental Products, Inc.     based in Whitehall, PENNSYLVANIA (USA)

The PACE Heated Stack Filter Box is constructed of 316 Stainless Steel and designed to be mounted in an outdoor environment on an emissions stack. A stainless steel probe extending halfway into the stack is connected to a 3' 150 lb. 304 Stainless Steel flange, drilled and tapped to accept a 3/4' npt fitting. On the opposite side of the flange is a ...

Test Ports

by L&E America     based in Kaukauna, WISCONSIN (USA)

Test ports for measuring flowrates, measuring pressures, and sampling during oxidizer compliance testing are installed on all TANN regenerative thermal oxidizers or other oxidizer design. TANN locates outlet test ports on exhaust stacks and usually fabricates inlet test ports on oxidizer inlet ductwork. This permits sampling and measurements ...

Model 270SF Series - Heated Stack Filter

by Universal Analyzers Inc. - AMETEK, Inc     based in Carson City, NEVADA (USA)

The 270SF is a Heated Stack Filter Assembly consisting of the filter body mounted in a NEMA 4X Fiberglass Enclosure or Stainless Steel Enclosure. An optional blowback system may be provided to allow the blowback to occur on command from a computer, data logger, PLC, or external switch mounted in a safe area.

Model 275E - Extractive Heated Stack Filter

by Universal Analyzers Inc. - AMETEK, Inc     based in Carson City, NEVADA (USA)

The Model 275 Heated Filter is designed to minimize the cooling of the sample at the inlet in order to avoid condensation of the water vapor in the sample. Two 125 watt and one 250 watt heaters are mounted inside the Filter Heater Tube halves. This heater tube assembly holds the temperature of the filter either at 340ºF or 375ºF with a ...

CES - Model Xact™ 640 - Stack Monitor

by Cooper Environmental Services, LLC     based in Beaverton, OREGON (USA)

For efficient pollution control, CES’ Xact™ 640 system uses reel-to-reel (RTR) filter tape sampling and nondestructive X-ray fluorescence (XRF) analysis to monitor stack hazardous air pollutant (HAP) metal emissions. An isokinetic sub-sample of stack gas goes into the stilling chamber and then drawn through a chemically ...

EPA Method - Model 16a - Basic Stack Sampling System

by Keika Ventures, LLC (KV)     based in Chapel Hill, NORTH CAROLINA (USA)

Method 16a - Determination of Total Reduced Sulfur Emissions from Stationary Sources. This manual method has been replaced by more automated systems in the U.S., but is still frequently requested from samplers outside the U.S. so we have decided to provide a listing of the component pieces needed for this system.

Need help finding the right suppliers?