Hydrocarbon Monitoring Equipment in Moldova

Serving Moldova | Near Moldova
330 Results found
  • Category: Monitoring & Testing ×

  • Subcategory: Hydrocarbon Monitoring ×

  • Location: Europe ×

  • Location: Moldova ×

VIG Industries - Model 210 Heated Methane/Ethane/NonMethane-Ethane - Total Hydrocarbon Analyzer (NMHC)

by VIG Industries     based in Anaheim, CALIFORNIA (USA)

The VIG Industries, Inc. Model 210 is a microprocessor based, oven heated methane / ethane / non methane-ethane (NMEHC) total hydrocarbon analyzer for high accuracy, sensitivity and stability. The Model 210 measures methane, ethane, non methane-ethane hydrocarbons at preset intervals and continuously measures total hydrocarbons in real time. The ...

Gaseeker - Gas Leak Detection

by Telegan Gas Detection     based in Oxfordshire, UNITED KINGDOM

Dual range 0-100%LEL/ 0-100% volume monitor for leak detection and purge monitoring of gas systems. Incorporating twin hydrocarbon detection technology, Gaseeker monitors hydrocarbons in inert backgrounds at % volume levels for gas pipe system purging and inert atmosphere monitoring, and has a % LEL sensor for gas escape testing. The Gaseeker's ...

Model CAI 600 Series - HFID Hydrocarbon Analyzer

by California Analytical Instruments, Inc. (CAI)     based in Orange, CALIFORNIA (USA)

The California Analytical Instruments Model 600 HFID Analyzers are designed to continuously measure the total concentration of hydrocarbons within a gaseous sample. The analyzers exhibit superior sensitivity and response time. The gaseous sample can be exhaust gases from an internal combustion engine, a combustion process or VOC abatement systems. ...

Model NB1000 - NUTRI-BIO For Petroleum Spills On Water

by A&V Envirotech     based in Milwaukee, WISCONSIN (USA)

This product was formerly listed on the U.S. National Contingency Plan Product Schedule as a biological additive. NUTRI-BIO 1000 is a patented complex formulation containing a broad range of organic and inorganic nutrients, energy sources, natural alcohol and enzymes from fermentation, and several biodegradable surfactants. This product ...

UviLux - UV In-Situ Fluorometer

by Chelsea Technologies Group     based in West Molesey, UNITED KINGDOM

The UviLux is a family of sensitive, low cost, digital in-situ UV fluorometers designed for real-time monitoring of concentrations of refined & crude hydrocarbons, Coloured Dissolved Organic Matter (CDOM) and Tryptophan, a surrogate marker for Biological Oxygen Demand (BOD), optical brighteners and bacterial contamination in waste, recycled and ...

Model BA 6000 - IR - NDIR Gas Analyzer Single or Dual Channel Version

by Bühler Technologies GmbH     based in Ratingen, GERMANY

The BA60001R single or dual channel gas analyzer operates as a NDIR instrument. It is ideally suited to measure any gas in the IR region between 2 and 9 µm, such as CO, CO2, NO, SO2, NH3, H2O, CH4 and other hydrocarbons. Single channel analyzers measure one gas component while dual channel analyzers measure two gas components simultaneously ...

Model 9500 - Bacti-Bio

by A&V Envirotech     based in Milwaukee, WISCONSIN (USA)

Bacti-Bio 9500 is a powder concentrate designed to digest a broad range of substrates. The multiple microbial strains in Bacti-Bio 9500 are naturally occurring and nonpathogenic. The select strains are hyperproducers of amylase, protease, cellulase, keratinase, lipase and pectinase enzymes. Several strains produce biosurfactants. .

PetroFLAG - Model PF-MTR-01 - Total Petroleum Hydrocarbon Kit

by Dexsil Corporation     based in Hamden, CONNECTICUT (USA)

Relying on laboratory methods to determine hydrocarbon contamination in soil is both time consuming and expensive. Laboratory methods, such as EPA Method 8015, are very expensive and have turnaround times of one to two weeks. Most samples analyzed by this method limit the results to Gasoline Range Organics (GRO) or Diesel Range Organics (DRO). ...

Model 529 BZ - FID Benzene Automatic Analyzer

by PCF Elettronica S.r.l.     based in Levate (BG), ITALY

The PCFs Mod. 529 NMH (Non Methane Hydrocarbon) gas chromatographic analyser is intended for measurements of reactive hydrocarbons in ambient air by subtracting from the concentration of total hydrocarbons the methane fraction. The separation of methane fraction is based on the chromatographic technique. A sample pump on the back of the pneumatic ...

PointWatch - Model PIR9400 - Infrared Hydrocarbon Gas Detector

by Det-Tronics - Detector Electronics Corporation     based in Bloomington, MINNESOTA (USA)

The PointWatch detector is a diffusion-based point-type infrared gas detector approved to provide continuous monitoring of methane gas concentration in the range of 0 to 100% LFL. The detector provides a 4-20 mA output signal, corresponding to the detected gas concentration. The detector has Division and Zone explosion-proof ratings and is ...

Need help finding the right suppliers?

Let the XPRTs do the work for you