Chlorine Dosing System: One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Chlorine Dosing System adds chlorine to feed water source, protecting the system from bio-fouling.
Booster Pump
Delivers feed water to RO plant at 40~50 psi under required feed water flow rate. Grundfos, Tonakflo or others. 316 stainless steel.
Multi-Media Filter
Multi-media filtration system is used to filter sand and sediment (turbidity) down to approximately 20 Microns. Both automatic and manual backwash option is available. Corrosion resistant, high performance composite & fiberglass tank will be used to hold the media.
Activated Carbon Filter
Activated carbon filtration system is used to remove chlorine from feed water, which protects TFC membrane from damaging chemical reaction with chlorine. Both automatic and manual backwash option is available. Corrosion resistant, high performance composite & fiberglass tank will be used to hold the media.
Pre-Filtration System
5 micron cartridge type sediment filter further reduces suspended solids in the feed water stream to RO system.
Sodium Metabisulfite Dosing System
One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Sodium Metabisulfate Dosing System neutralizes chlorine, which is added in the feed water to reduce bacteria. The residual serves as an excellent biocide, which prevents membranes from bio-fouling.
Acid Dosing System
One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Chemical Dosing System prevents membrane scaling.
Antiscalant Dosing System
One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Antiscalant Dosing System prevents the membrane from scaling.
Caustic Dosing System
(Post Treatment)
One metering injection systems will be supplied for controlling different elements in the product water of the RO plant. The metering pump will allow to control different functions such as the stroke length and percentage rate. The Caustic Dosing System adjusts product water pH.
Chlorine Dosing System
(Post Treatment)
One metering injection systems will be supplied for controlling different elements in the product water of the RO plant. The metering pump will allow to control different functions such as the stroke length and percentage rate. The Chlorine Dosing System sterilizes product water.
UV Sterilization System
(Post Treatment)
Sterilizes product water by alternating the DNA structure inside bacteria.
Ozone System
(Post Treatment)
Sterilizes product water by burning off the outer membrane of bateria.
Six conditions will cause the RO to shut down the machine:
Membrane Cleaning/Flushing System
Includes high flow pump, 316 SS, heater. It cleans membranes when needs, extends membrane life. Use chemicals for cleaning. Automatic cleaning/flushing. Installed with automation, valves. Etc. With common service tank for product/cleaning/flushing. The cleaning system has pressure transmitter at In/Out of each membrane vessel. If Delta P is greater than design Delta P, then audio and visual alarm will trigger.

No comments were found for 20,000-264,000 GPD - Seawater Desalination System. Be the first to comment!