- FGA 900 Series - Range of Stack Gas Emissions Analysers

From
0.511.522.533.544.55 (0 votes)
Land - FGA 900 Series - Range of Stack Gas Emissions Analysers

The FGA range of analyzers use dual sensor technology to measure the levels of Nitrogen Oxides, Carbon Monoxide and Oxygen in flue gas. O2, CO, NO, NO2, NOX.

Key Features:

  • Fully integrated system in a single compact box - no additional components required
  • Suitable for a wide range of applications - up to 3 gases in a single analyzer
  • Low maintenance - straightforward servicing without specialist skills
  • Proven high performance - dual sensor measurement technique, TÜV & MCerts approved/Certified to US EPA standards
  • True measured Total NOx - separate NO + NO2 sensors for true NOx monitoring, no converters necessary
  • Simple installation - locate the analyzer anywhere, including outside locations
  • Automatic calibration option - for continuous unattended operation in compliance monitoring applications
  • Combustion Efficiency measurement option - for optimizing process efficiency where conditions are changing

Detail:

The FGA range of analyzers use dual sensor technology to measure the levels of Nitrogen Oxides, Carbon Monoxide and Oxygen in flue gas.

This range of gas analysers carry a wide range of compliance and performance approvals including those from the US-EPA, UK MCERTS and German TÜV.

Land’s measurement technique ensures stable long-term operation with high accuracy and very low drift. Engineered for ease of maintenance and packaged for the industrial environment, FGA series analyzers are simple to install and trouble-free in operation.

Measurement Capability

FGA 900 Series stack gas emissions analysers can measure up to 3 gases in a single instrument.

  • Carbon Monoxide (CO)
  • Oxygen(O2)
  • Nitric Oxide (NO)
  • Nitrogen Dioxide (NO2)
  • Nitrogen Oxides (NOx)
  • Carbon Dioxide (CO2) Calculated

Compact, Weatherproof Design

The FGA stack gas emissions analyser is very compact. The choice of installation location and access is therefore made much simpler. They are packaged in weatherproof cabinets, intended for mounting directly on to a convenient wall or structure, inside or outside.

True NOx Measurement

The analyzer measures both NO and NO2 separately, these are combined to give a true NOx measurement output. The inherent problems with catalytic NO2 converters are therefore completely avoided.

Technical Details:

Measurement Ranges

  • CO Ranges: 0 - 50 ppm up to 0 - 2 000 ppm
  • NO Ranges: 0 - 50 ppm up to 0 - 2 000 ppm
  • NO2 Ranges: 0 - 50 ppm up to 0 - 200 ppm
  • Resolution: 1 ppm / 1 mg/m3
  • Linearity: < 2 % of range
  • Zero drift: < 2 % of range per month
  • Span drift: < 2 % of range per month
  • O2 Ranges: 0 - 5 % to 0 - 25 %
  • Resolution: 0.1 Vol %
  • Linearity: < 0.2 Vol %
  • Zero drift: < 0.2 Vol % per month
  • Span drift: < 0.2 Vol % per month
  • Calibration: Microprocessor controlled
  • Standard: Manual gas selection
  • Display: LCD with backlight
  • Indicators: External 'Power On' and 'System OK' LEDs

Outputs/Inputs:

  • Analog output:
    • Isolated current loop outputs
    • One per gas measured plus NOx if NO & NO2 measured
    • Efficiency (on instruments with selected option)
    • 0, 2, or 4 to 10 or 20 mA
  • Relays outputs: System OK; Maintenance/Calibration
  • Relay rating:
    • Isolated changeover S.P. 1 A @ 240 V a.c.
    • 5 A @ 240 V d.c. resistive for
    • Alarm - one per gas measured
    • Span and Zero Gas Relays for calibration gases
  • Inputs: Current loop inputs for ambient and process temperatures (only needed for efficiency calculation)

Environmental

  • Environmental rating: IP65 / NEMA 4
  • Operating (ambient)   temperature:
    • 0 to +35 °C / 32 to 95 °F standard
    • to -20 °C / -4 °F with optional case heater
    • to + 50 °C / 122 °F with optional air conditioner

Compliance: 

  • Measurement standards: Meets the requirements of ISO 12039, ISO 10849 and ISO 7935
  • Approvals:
    • MCerts for Continuous Emissions Monitoring Systems (Nov 1998)
    • TÜV approved to the 13th & 17th BImSchV and
    • TA Lüft
    • USEPA certified to PS-3, PS-4 and PS-4A
  • Electrical safety: Conforms to EN-61010-2
  • EMC: Conforms to EN-50 081 & EN-50 082

Power

  • Power Supply: 110 V a.c. or 230 V a.c., ±20 %, 50 - 60 Hz
  • Power Consumption: 300 W

Gas & Air Requirements

  • Instrument air (zero calibration): 2 bar / 30 psi clean and dry, 5 l/min /0.2 cfm
  • Instrument air (cooling): 2 - 10 bar / 30 - 150 psi clean and dry, 90 l/min / 3 cfm
  • Calibration gas   (recommended):
    • 2 bar / 30 psi, 5 l/min /0.2 cfm
    • 20 litres / 0.7 cu.ft. per calibration approx.
  • Calibration gas type: Specific to each gas type and measurement span
  • Dimensions
    • (H x W x D): 600 x 600 x 350 mm / 24 x 24 x 14 in
    • Weight: 53 kg / 117 lb

Options

  • Special measurement ranges
  • Automatic calibration
  • Efficiency measurement
  • Probe type
  • Sample line type
  • Case heater
  • Air conditioner/vortex cooler
Land Instruments International