- INM-700 - In-Situ NOx/O2 Monitor

From
0.511.522.533.544.55 (0 votes)
HORIBA - INM-700 - In-Situ NOx/O2 Monitor

HORIBA's INM-700 in-situ gas analyzer is designed to meet the requirements of coal-fired power generation plants for cost-effective, low maintenance NOX monitoring. The analyzer uses a ceramic diffusion filter and Zirconium Oxide sensor directly in the gas stream, which eliminates the need for an extraction process for sample collection, and results in lower maintenance. The INM-700 is ideal for inlet SCR control, NOX measurements, and burner balancing/combustion tuning in boiler plant operations.

The INM-700 has the advantage of lower installation, maintenance, and capital costs, and a faster response time. In addition, for compliance strategies, the ceramic filter allows measurements to be taken near the combustion point of the furnace. This technique utilizes combustion modification techniques such

  • Low NOX burners (LNB)
  • Over-fire air injection (OFA)
  • Gas re-burn systems
  • Boiler tuning
  • Combustion optimization programs

Application/Industries Served

  • SCR control
  • Inlet/outlet NOX measurement
  • Replacement of FGAS shelters
  • Burner balancing/combustion tuning
    • Improved burner efficiencies and reduction of NOX
    • Identifying problem areas in the furnace due to gas stratification linked to specific burner columns.

Características

  • A NOX sensor using a new technology for coal fired applications which can improve control of the ammonia injection rate in SCR systems.
  • A practical NOX sensor with a fast response time that can be directly installed in the combustion gas stream.
  • Extremely robust sensors that are long lived and capable of withstanding elevated temperatures.

Specification

  • Model: INM-700
  • Principle: Zirconium sensor type (Demarcation current)
  • O2: 0 to 25voL%
  • Repeatability: ±1.0% of full scale
  • Drift: ±2.0% of full scale/week
  • Response time(T90): 10 sec. or less
  • Linearity: ±3.0% of full scale
  • Warm up time: Approx. 5 min.
  • Display: LED digital display (effective 4 digits) for measuring value
    LCD display for parameter setting
  • Output signal: NOX: DC 4 to 20 mA, maximum permissible load 600 Ω
    O2: DC 4 to 20 mA, maximum permissible load 600 Ω
  • External output: NOX high/low-alarm, O2 high/low-alarm, Power failure alarm, Abnormal
  • Calibration: DRY calibration, Automatic (1 hour to 99 days 23 hours configurable), Manual
  • Calibration gas: O2 zero: Standard gas (NO), O2 span: Cylinder air, NO zero: Cylinder air, NO span: Standard gas (NO)
  • Sampling probe: Flange: JIS 5K 65A FF, Probe length: 520 mm [20.47 inch], Material: SUS316
  • Sensor cable length: Max. 50m [164 ft.]
  • Installation condition: Indoor or outdoor, operational temperature: -10 to 50°C [23 to 122°F], Humidity: 90% RH (non condensing)
  • Power: AC100V to 240V
  • Power consumption: Approx. 60VA
  • Frequency: 50/60Hz
  • Mass: Probe unit: approx. 10 kg [Approx. 22lbs]
    Controller unit: approx. 20kg [Approx. 44lbs]
  • Cooling air (Instruments air)3: Dew point: -20°C [-2°F] or less
    Pressure: Approx. 300kPa
    350°C to 400°C [662°F to 752°F]: Approx. 70 L/min.[2.47 cfm]
    300°C to 350°C [572°F to 662°F]: Approx. 50 L/min.[1.77 cfm]
    200°C to 300°C [392°F to 572°F]: Approx. 40 L/min.[1.41 cfm]
  • Purge air (Instrument air)4: Temperature: 25°C [77°F ] or less (No dust, mist and Non-condensing moisuture content: 0.6% of less at 0°C [23°F]
    Pressure: Approx. 300kPa
    Consumption: Approx. 3 L/min.
  • Sample gas condition5: Pressure: ±3kPa (constant with no fluctuation)
    Velocity: 20m/sec. or less
    Temperature: 400°C [752°F] or less
    Dust: 20g/m3 or less
    O2: 1 to 25 voL%
    CO2: 0 to 20 voL%
    H2O: 3 to 20 voL%
    SO: 1000ppm or less
    NH3: 1ppm or less
    H2: 500ppm or less
  • 1 Compared to the actual value, the measured value changes according to the moisture content in the target gas because of wet-basis measurements (effect on the indicated value by partial pressure of water).
  • 2 First week of operation at ±2.0% of full scale per day.
  • 3 No oil, mist and dust. When instruments air cannot be arranged that safisfies these conditions, handle by arranging a small compressor or similar equipment.
  • 4 Instead of cylinder air, instrument air that is free of oil and mist may be used for calibration and purge air.
  • 5 Make sure not to include components other than those listed in the sample gas conditions. Speficically, when there are corrosive or poisonous components (such as F, Cl, Si, Pb, Zn, Sh, As) , the sensor may degrade in a short period of time.