Oxidirect - Model BOD - Measurement System

by Camlab Limited     based in Over, UNITED KINGDOM

The Oxidirect sensor system is a six or twelve sample system that allows precise measurement of BOD based on the manometric principle.

Jenway - BOD Accessories

by Bibby Scientific Limited     based in Stone, UNITED KINGDOM

Biological Oxygen Demand or BOD serves as an indicator of water pollution in water quality management. BOD5 measures the amount of oxygen consumed by aerobic bacteria in the breakdown of organic matter in a sample of water over 5 days in the dark at 20°C. The greater the value, the higher the degree of pollution.

AppliTek Ra-BOD - On-line BOD Analyzer

by AppliTek NV - Environmental Analysis Division     based in Nazareth, BELGIUM

The Ra-BOD is a unique process analyzer for determining short-term Biological Oxygen Demand (BODst) in waste water and surface water and fits into a control strategy for activated sludge plants. The respiration rate (expressed as mg O2/l.h) is one of the most important parameters for the biological activity of activated sludge. Consequently, the ...

Ovivo - Containerized Membrane Bioreactors (MBR)

by Ovivo (Formerly Eimco Water Technologies)     based in Salt Lake City, UTAH (USA)

Designed for rapid deployment, easy maintenance and minimal operator involvement, Ovivo’s Containerized Membrane Bioreactors (MBR) provide wastewater treatment solutions for military field operations, aid relief operations and construction camp use worldwide. The value added benefit; (typically with 50% less tank volume compared to ...

LAR - Model BioMonitor - BOD Analyser

by LAR Process Analysers AG     based in Berlin, GERMANY

Measurement range: 1-200.000 mg/l BOD, 0-100 % Toxicity, Respiration in mg O2/l x min. Response time: 3-4 min. (customizable). High degradation. Sludge activity. Using the plant's own biomass. No memory effects.

BODChek - Portable BOD Detection to Provide Real Time Monitoring of Organic Pollution

by Modern Water - Monitoring Division     based in Cambridge, UNITED KINGDOM

BODChek enables in-situ, real-time, monitoring of Biological Oxygen Demand (BOD) within both natural water systems and water processing plants. The monitor detects fluorescent proteins that are inherent within sewage and slurry and provides an output in BOD equivalent units.

AppliTek Ra-COMBO - At-Line BOD Analyzer and Toxicity Analyzer

by AppliTek NV - Environmental Analysis Division     based in Nazareth, BELGIUM

The Ra-COMBO is a renowned respirometric at-line analyzer for conducting semi-automated analysis on the biolgical activity of activated sludge. The system basically measures the respiration rate (expressed as mg O2/l.h), one of the most important parameters for the biological activity of activated sludge. The analyzer determines short-term ...

Hach Lange - Model BOD Trak II - Reactor

by DelAgua Group     based in Marlborough, UNITED KINGDOM

Simplify BOD analysis with the Hach-Lange BODTrak™ II Respirometric BOD Apparatus. Results comparable to the dilution method can be achieved in only two to three days. Use these results for process control or as a complement to the dilution method (not approved by USEPA for NPDES reporting purposes).The BODTrak II is a re-engineered version of the ...

OxiTop - Model Control AN6/AN12 - Biogas Determination Control

by WTW GmbH - a xylem brand     based in Weilheim, GERMANY

Anaerobic degradation processes take place in the absence of oxygen. A septum sealed bottle nozzle fills the head space above the sample with inert gas. When anaerobic degradation has taken place, the dissolved CO2 can be driven off and then removed from the head space by means of a CO2 absorber. The resulting pressure difference is proportional ...

Model OxiTop Control A6/A12 and OxiTop Control S6/S12 - Determination of Biodegradability in Water

by WTW GmbH - a xylem brand     based in Weilheim, GERMANY

The determination of the biodegradability should be checked before new chemicals are used for the first time, not only for environmental reasons but to minimize disposal charges. The sample and a blank are stirred at a constant temperature for 28 days in closed bottles. The CO2 produced is removed by means of an absorber, the resulting negative ...