gas filters Equipment in Bangladesh

1612 Results found
  • Keyword: gas filters ×

  • Location: Asia & Middle East ×

  • Location: Bangladesh ×

TAPI - T300 - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law.

TAPI - 300E - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model 300E measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy light source to pass through a CO filled chamber and a chamber with no CO present. The ...

TAPI - 300EM - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model 300EM measures carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy light source to pass through a CO filled chamber and a chamber with no CO present. The light path then ...

CeraQ - Ceramic Filter Modules

by QUA Group

CeraQ ceramic filter membranes offer superior performance in challenging oil removal applications and are ideal for wastewater recycle / reuse applications in a wide range of industries such as upstream oil & gas, petrochemicals, refinery, food & beverage, and textiles. Each CeraQ module is available in four different pore sizes: 0.4, 0.05, 0.01 ...

MicroPNS - Gas Collector Control Module

by Umwelttechnik MCZ GmbH

Collection on filter plates for the subsequent laboratory analysis (heavy metals) in samples. Control module MicroPNS as 19' rack model with switch for 8 filters. Collection system is mounted in a measuring station.

Hilliard HILCO - Dry Seal Gas Integral Duplex Filters

by The Hilliard Corporation - Star Systems Filtration Division

Dry Seal Gas Integral Duplex Filters simplify piping and operation of the duplex filter arrangement. Duplex housings incorporate valves and filters into one assembly. HILCO gaseous fuel filters are available in simplex design and in duplex arrangements for continuous operation. The filters are specifically designed for gas turbine systems with ...

TAPI - T300M - Mid-Range Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model T300M CO analyzer measures low ranges to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO ...

TAPI - T360 - Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then ...

TAPI - T320 - Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model T320 N2O analyzer measures Nitrous Oxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a N2O filled chamber and a chamber with no N2O present. The light path then ...

TAPI - 360EM - Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)

The Model 360EM measures carbon dioxide CO2 by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law. This is accomplished by using a Gas Filter Wheel which alternately allows a high energy infrared light source to pass through a CO2 filled chamber and a chamber with no CO2 present.

Need help finding the right suppliers?

Let the XPRTs do the work for you