gas filters Equipment in Latvia

Serving Latvia | Office in LatviaNear Latvia
2128 Results found
  • Keyword: gas filters ×

  • Location: Europe ×

  • Location: Latvia ×

TAPI - Model 360E - Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model 360E measures carbon dioxide CO2 by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law. This is accomplished by using a Gas Filter Wheel which alternately allows a high energy infrared light source to pass through a CO2 filled chamber and a chamber with no CO2 present.

TAPI - Model 300EM - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model 300EM measures carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy light source to pass through a CO filled chamber and a chamber with no CO present. The light path then ...

TAPI - Model 300E - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model 300E measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy light source to pass through a CO filled chamber and a chamber with no CO present. The ...

TAPI - Model T360 - Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then ...

TAPI - Model T320 - Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model T320 N2O analyzer measures Nitrous Oxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a N2O filled chamber and a chamber with no N2O present. The light path then ...

TAPI - Model T300 - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law.

TAPI - Model 320E - Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model 320E measures Nitrous Oxide with excellent accuracy and stability due to the Gas Filter Correlation principle employed. The sample concentration is determined by measuring how much infrared light the gas absorbs as it flows through a multi-pass sample cell. The light is first coupled through a filter wheel that contains an inert gas in ...

TAPI - Model 360EM - Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model 360EM measures carbon dioxide CO2 by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law. This is accomplished by using a Gas Filter Wheel which alternately allows a high energy infrared light source to pass through a CO2 filled chamber and a chamber with no CO2 present.

Gas Clean Filters

by F-DGSi     based in Evry Cedex, FRANCE

Clean Gas Filters can be installed within seconds without disturbing the technical and analytical performance of the gas-chromatographic system. These cartridges do not connect directly in to the gas line like a typical in-line filter, but onto a specially designed base plate, allowing a diffusion-proof installation without the use of tools. The ...

TAPI - Model T300M - Mid-Range Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation, Inc. (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model T300M CO analyzer measures low ranges to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO ...

Need help finding the right suppliers?

Let the XPRTs do the work for you