Model T320U - Ultra-Sensitive Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T320U N2O analyzer measures Nitrous Oxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a N2O filled chamber and a chamber with no N2O present. The light path then ...

Model T320 - Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T320 N2O analyzer measures Nitrous Oxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a N2O filled chamber and a chamber with no N2O present. The light path then ...

Model T300U - Ultra-Sensitive Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T300U Ultra-Sensitive CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US ...

Model T300 - Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law.

Model T300M - Mid-Range Gas Filter Correlation CO Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T300M CO analyzer measures low ranges to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO ...

Model T360U - Ultra-Sensitive Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T360U CO2 analyzer measures of Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path ...

Model T360 - Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then ...

Model T360M - Mid-Range Gas Filter Correlation CO2 Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then ...

Model 320E - Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model 320E measures Nitrous Oxide with excellent accuracy and stability due to the Gas Filter Correlation principle employed. The sample concentration is determined by measuring how much infrared light the gas absorbs as it flows through a multi-pass sample cell. The light is first coupled through a filter wheel that contains an inert gas in ...

Model 320EU - Ultra Sensitive Gas Filter Correlation N2O Analyzer

by Teledyne Advanced Pollution Instrumentation

The Model 320EU measures trace levels of Nitrous Oxide with excellent accuracy and stability due to the Gas Filter Correlation principle employed. The sample concentration is determined by measuring how much infrared light the gas absorbs as it flows through a multipass sample cell. The light first passes through a filter wheel that contains an ...


Air & ClimateEnergy & RenewablesEnvironmental ManagementHealth & SafetyMonitoring & TestingSoil & GroundwaterWaste & RecyclingWater & Wastewater