solvent separation Equipment

248 Results found
  • Keyword: solvent separation ×


PSS - Model MCX - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Aqueous Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Sulfonated Polyanions, Poly(styrenesulfonate), Lignin sulfonate, Modified Starches, Acids, Alcohols, pectins, etc.). Eluents  : Water, water with salt/buffer, MeOH, ACN); pH: 7 - 13. Material : Sulfonated styrene-divinylbenzene copolymer-network. Maximum Pressure : 100 - 150 bar (1450 - 2180 psi), depending on porosity. ...

PSS - Model PROTEEMA - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Aqueous Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Natural and synthetic Proteins, Peptides, Enzymes, Gelatins/Collagens. Eluents : Water, water with salt/buffer; pH: 2 -9. Material : Special modified silica. Maximum Pressure: 150 - 200 bar (2180 - 2900 psi), depending on porosity. Maximum Temperature: 70° C. Maximum Flow Rate: (8 mm I.D.) 3 ml/min. Particle Size : 3 µm, ...

PSS - Model NOVEMA Max - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Aqueous Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Cationic polymers, (Polymeric Quarternary Ammonium Compounds, Poly (DADMAC), Poly(vinylpyridine), Chitosan, Poly(ethyleneimine), etc.). Eluents : Water, water with salt/buffer, MeOH, ACN, TFA); pH: 1.5 - 7. Material : NH-functionalized acrylate copolymer network. Maximum Pressure : 5.0 - 80 bar (725 - 1160 psi), depending on ...

PSS - Model SUPREMA - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Aqueous Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability :Neutral and anionic polymers, (PEO, PEG, Pullulan, Dextran, Poly(acrylamide), Hyaluronic acid, Poly(acrylic acid), Carboxymethylcellulose, etc.). Eluents :water (with salts/buffers, MeOH, ACN) pH: 1.5 – 13. Material :Polyhydroxymethacrylate copolymer network. Maximum Pressure :50 - 80 bar (725 - 1160 psi), depending on ...

PSS - Model SDV - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Organic Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Poly(styrene), Poly(vinyl chloride), Poly(carbonate), Elastomers, Resins and others. Eluents: THF, Toluene, TCM, DCM. Material : Styrene-divinylbenzene copolymer network. Maximum Pressure: 45 - 150 bar (650 - 2180 psi), depending on porosity. Maximum Temperature: 100° C. Maximum Flow Rate : 3 ml/min (I.D.: 8 mm, 5 µm ...

PSS - Model PolarSil - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Organic Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Polyurethane, Polyimide, Starches, Celluloses, certain Polyamide, other polar polymers. Eluents: DMF, DMAc, NMP, DMSO. Material : Polyester copolymer network. Maximum Pressure: 50 -120 bar (725 - 1740 psi), depending on porosity. Maximum Temperature : 90° C. Maximum Flow Rate: 2 ml/min (I.D.: 8 mm). Particle Size: 10 µm. ...

PSS - Model PFG - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Organic Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Crystalline polymers, Polyesters, Nylons, Poly(lactide), POM, etc. Eluents : HFIP, TFE, other fluorinated solvents. Material : Modified silica. Maximum Pressure : 150 - 200 bar (2180-2900 psi), depending on porosity. Maximum Temperature : 90° C. Maximum Flow Rate : 3 ml/min (I.D.: 8 mm). Particle Size : 5 µm, 7 µm. ...

PSS - Model POLEFIN - Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) Columns Soluble in Organic Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Poly(ethylene), Poly(propylene), other Polyolefins. Eluents: TCB, o-DCB, Decalin. Material: Modified styrene-divinylbenzene copolymer network. Maximum Pressure: 100 - 150 bar (1450 - 2180 psi), depending on porosity. Maximum Temperature: 200° C. Maximum Flow Rate : 2 ml/min (I.D.: 8 mm). Particle Size: 10 µm, 20 µm. ...

PSS - Model GRAM - Columns for Polar Polymers in Medium Polar Organic Solvents

by Polymer Standards Service-USA Inc.     based in Mainz, USA

Applicability : Polyurethane, Polyimide, Starches, Celluloses, certain Polyamide, other polar polymers. Eluents: DMF, DMAc, NMP, DMSO. Material : Polyester copolymer network. Maximum Pressure: 50 -120 bar (725 - 1740 psi), depending on porosity. Maximum Temperature : 90° C. Maximum Flow Rate: 2 ml/min (I.D.: 8 mm). Particle Size: 10 µm. ...

Alliance HPLC System - HPLC has never looked better...

by Waters Corporation     based in Milford, MASSACHUSETTS (USA)

- Time-tested, flexible, and reliable workhorse for your HPLC separations- New industrial design, exemplifying Waters' continued commitment to our industry-trusted HPLC line- Bridge the gap between HPLC and UPLC performance with XP 2.5 µm columns- Integrated solvent and sample management to ensure consistent system-to-system performance and high ...

Need help finding the right suppliers?

Let the XPRTs do the work for you