Contact Now/Request quote View Phone/Fax Number Visit Website

Model T320U - Ultra-Sensitive Gas Filter Correlation N2O Analyzer

From T Series Instruments - Analyzers for Nitrogen Compounds

0.511.522.533.544.55 (0 votes)
Model T320U - Ultra-Sensitive Gas Filter Correlation N2O Analyzer

The Model T320U N2O analyzer measures Nitrous Oxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a N2O filled chamber and a chamber with no N2O present. The light path then travels through the sample cell, which has a folded path of 14 meters. Inferences from H2O and CO are eliminated using a Nafion dryer and precious metal catalyst.


The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from Interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent interference free performance in the low range.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.


Features

Features


  • Ranges: 0-200 ppb to 0-200 ppm, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Comprehensive internal data logging with programmable averaging periods
  • Ability to log virtually any operating parameter
  • Two-year warranty
  • Five-year warranty on GFC wheel


General

  • Ranges
    • Min: 0-200 ppb Full scale
    • Max: 0-200 ppm Full scale (selectable, dual ranges and auto ranging supported)
  • Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
  • Zero Noise: < 5 ppb (RMS)
  • Span Noise: < 0.5% of reading (RMS)
  • Lower Detectable Limit: <10 ppb
  • Zero Drift: < 25 ppb/24 hours
  • Span Drift: < 0.5% of reading/24 hours
  • Lag Time: < 10 seconds
  • Rise and Fall Time: < 60 seconds to 95%
  • Linearity: 1% of full scale
  • Precision: 0.5% of reading
  • Sample Flow Rate: 800 cm3/min ±10%

Electrical Specifications

  • Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
  • Analog Output Ranges: 10V, 5V, 1V, 0.1V (selectable)
  • Recorder Offset: ±10%

Communication Specifications

  • Included I/O
    • 1 x Ethernet: 10/100Base-T
    • 2 x RS232 (300-115,200 baud)
    • 2 x USB device ports
    • 8 x opto-isolated digital outputs
    • 6 x opto-isolated digital inputs
    • 4 x analog outputs
  • Optional I/O
    • 1 x USB com port
    • 1 x RS485
    • 8 x analog inputs (0-10V, 12-bit)
    • 4 x digital alarm outputs
    • Multidrop RS232
    • 3 x 4-20mA current outputs

Physical Specifications

  • Operating Temperature Range: 5 - 40ºC
  • Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
  • Weight: 50 lbs (22.7 kg)

Teledyne Advanced Pollution Instrumentation
Teledyne Advanced Pollution Instrumentation
9480 Carroll Park Drive
San Diego ,  California 92121
DOWNLOADS

DOWNLOADS


RELATED KEYWORDS

MOST POPULAR RELATED SEARCHES

Post a new comment
Post your comment
View comments

No comments were found for Model T320U - Ultra-Sensitive Gas Filter Correlation N2O Analyzer. Be the first to comment!



Air & ClimateEnergy & RenewablesEnvironmental ManagementHealth & SafetyMonitoring & TestingSoil & GroundwaterWaste & RecyclingWater & Wastewater