Contact Now/Request quote View Phone/Fax Number Visit Website
OPSIS - SM200 - Beta-Attenuation Particulate Monitor / Gravimetric Sampler

The SM200 is an automatic particulate monitor for monitoring of PM10 and PM2.5. A filter is loaded into the filter magazine and a Geiger counter detects the beta attenuation before and after sampling. The response time of the instrument is 1–24 hours.


Fo those who would like data resolution down to less than 1 hour, the optional RTPM (real-time particulate module) uses a laser nepthalometer system to measure concentration levels down to 1-minute resolution. The RTPM is a small additional unit installed between the PM inlet head and the SM200 monitor.

  • MCERTS Approved (PM10)
  • CEN 1234-1 Equivelent Method
  • 40 x Filter Gravimetric Sampler
  • Large Capacity Internal Data Logger
  • Compact Dimensions
  • Excellent Build Quality & Reliability

A Total Solution For Monitoring of Particulate Matter

A Total Solution For Monitoring of Particulate Matter


The particulate matter monitor SM 200 can be used for both automatic measurement and filter sampling. Thee SM 200 can be equipped with a PM10 head or a PM2.5 head, designed for either 2.3 m3/h or 1.0 m3/h.

The SM 200 is a cost-effective solution for particulate matter monitoring and sampling. It can be completely remote controlled and is ideally suited for use in modern monitoring stations.

The SM 200 can generate both 24-hour data based on beta attenuation and real time data based on differential pressure measurements. Due to the extensive automatic QA/QC procedures, the SM 200 operates with high accuracy and precision.

The SM 200 meets the new regulation for automatic monitoring of PM10 and PM2.5. It also meets the new regulation for particulate matter sampling on filter membranes for further analysis of cadmium, nickel, PAH and other substances.


Features

Features


Image

Monitoring and Sampling
The SM 200 provides both automatic monitoring of particulate matter as well as sampling of air on membrane filters. Standard 47 mm membrane filters are used.

International Approvals

  • Approved by UBA, CNR among others
  • Reference sampler according to EN 12341, when equipped with 2.3 m3/h inlet head.

Beta Attenuation
The SM 200 is an automatic particulate monitor for monitoring of PM10 and PM2.5. A filter is loaded into the filter magazine and a Geiger counter detects the beta attenuation before and after sampling. Thee response time of the instrument is 1–24 hours.



Image

Real Time Measurements
The SM 200 can generate real time data by using differential pressure measurements. Hourly mass concentration values are presented based on the pressure drop over the filter during sampling. This gives a good estimate of the actual mass concentration.

The differantial pressure measurement is calibrated daily, using the results from the beta attenuation.

Built-in Calibration
Span, linearity and zero calibrations are automatically controlled at regular intervals.

TS 200 – Temperature Stabilized Inlet Tube
TheTS 200 is used for keeping the sample air at ambient temperature. Since the temperature of the sample is controlled, no factors have to be added to the measurement results. This means that the SM 200 always provides accurate results, unaffected by both seasonal and geographical factors. The TS 200 is available as an option and has to be ordered separately.

QA/QC Procedures
The 47 mm filters can be weighed according to gravimetric reference methods. The results can be used for quality control of the automatic measurements.



Extensive QA/QC procedures regulate the operation of the SM 200 by use of internal sensors such as:

  • External temperature
  • External pressure
  • Filter temperature
  • Filter relative humidity
  • Filter pressure drop
  • Inlet flow rate
  • Geiger temperature
  • Geiger counts
  • Geiger high voltage

Serial Communication – Remote Control
The instrument is equipped with three RS 232 serial ports that can be used for connecting the SM 200 to a PC, modem or data logger. By using the serial ports, the SM 200 can be remotely controlled, which means that data retrieval and other operations can be performed at distance. The SM 200 is ideally suited for use in a monitoring network.


Technical Specifications

Technical Specifications


  • Dimensions, sampling module: 440 × 630 × 300 mm.1
  • Dimensions, pumping module: 310 × 280 × 250 mm.1
  • Weight, sampling module: 25 kg
  • Weight, pumping module: 10 kg
  • Voltage supply: 230 V/50-60 Hz
  • Power consumption: 800 W
  • Display: LCD, 4 × 20 characters
  • Keypad: Membrane
  • Data storage: > 100 sets of data
  • Serial interface: 3 × RS 232
  • Analogue output: 0 –10 V/4–20 mA
  • Digital status output: Closing relay
  • Degree of protection: IP 20
  • Operating temperature: +5˚C– +35˚C, (+40˚F – +100˚F)

Performance

  • Operative flow rate: 16.67 l /min alt. 38.3 l /min
  • Mass measurement range: 0 –1000 μg/m3
  • Detection limit: 0.5 μg/m3 (24 h average)
  • Response time: 1–24 h, beta attenuation, 1–24 h, differential pressure measurements

Radioactive Source Data

  • Source: 14C polymethyl methacrilate
  • Total activity: 9.9 Mbq (267 μCi)
  • Specific activity: 55.5 Mbq/g (1.5 mCi/g)
  • Half life: 5730 years
  • Type: Beta

SM 200 Includes as Standard

  • Analyser unit 230/115 V, 1.0 m3/h
  • Pump module 230 V
  • Beta source
  • 2 filter containers
  • 40 filter holders
  • 2.5 metres stainless steel inlet tube

Enviro Technology Services plc
Enviro Technology Services plc
Kingfisher Business Park, London Road
Stroud , Gloucestershire; GL5 2BY
DOWNLOADS

DOWNLOADS


RELATED KEYWORDS

MOST POPULAR RELATED SEARCHES

Post a new comment
Post your comment
View comments

No comments were found for OPSIS - SM200 - Beta-Attenuation Particulate Monitor / Gravimetric Sampler. Be the first to comment!



Air & ClimateEnergy & RenewablesEnvironmental ManagementHealth & SafetyMonitoring & TestingSoil & GroundwaterWaste & RecyclingWater & Wastewater