EWL, EWL-15, EAL and EGL series samplers are packed by one in air tight cans. Please read handling instruction below.
| EWL-PRC - Exposmeter Lipophilic PRC for Water – Brochure | |
| Product Handling – Brochure |
Economy. No additional electrical equipment needed for sampling. EWL series samplers offers full-shift to 30-day sampling; you only need one sampler for a TWA sample, and one sampler means only one analysis.
Efficiency. No need to make multiple worksite visits to change sampling media; 30-day sampling can be done with just ONE sampler.
The cost, ease of usage, sensitivity, reproducibility, and application to water concentrations it makes EWL series samplers the best available passive environmental sampler.
EWL series samplers are the only demonstrated in situ passive monitoring approach for sampling sub-part-per-quadrillion levels of dissolved residues such as dioxins.
The compounds listed below are the example of common contaminants sampled by EWL series samplers. Many other hydrophobic substances with a -log Kow greater than 3.0 can be sequestered in triolein and ultimately analyzed.
Name Possible Source
PAH Polycyclic Aromatic Hydrocarbons Combustion by-product
OC, OrganoChlorides Pesticide
PCB, Polychlorinated Biphenyls Industrial and electrical
Pyrethroids Insecticide
Dioxins Combustion, industrial
Furans Industrial by-product
Nonyl Phenols Industrial
Alkylated Selenide Fossil fuels
Oil C8 C36 Industrail, fossil fuel
TBTs Ships
Examples of toxicity tests:
Vibrio fischeri, acute toxicity test with cladophora Daphnia pulex , test with fish rainbow trout Oncorhynchus, mykiss and test of inhibition of algal growth of Scenedesmus subspicatus and/or Selenastrum capricornutum
For the purposes of monitoring Persistent Organic Pollutants (POPs) EWL series samplers can be included in monitoring programs to reveal environmental contamination and to investigate the bioavailability of contaminants from environmental media.
SPMD passive sampling technology have been used by many governmental agencies around the globe (e.g., UK EPA, Swedish EPA, Chzeck EPA, Australia EPA, US EPA, USGS) for the monitoring of water-soluble organic contaminants. The US EPA has been instrumental in developing the SPMD as an airborne contamination monitor. The Environmental Agency of England and Wales has adopted the SPMDs as part of their monitoring programs. The National Laboratory Service of the UK Environment Agency has been awarded accreditation for analysis of SPMD devices to the ISO17025 standard by the United Kingdom Accreditation Service (UKAS). The Institute of Public Health in the Czech Republic use EWL as a standard method. SPMD is being considered by the European Union as a standard method for dissolved phase chemicals.
EWL – Exposmeter Lipophlic for water
EWL consists of a neutral, high molecular weight lipid such as triolein which is encased in a thin-walled lay flat polyethylene membrane tube.
Performance:
Detection level
Method specific. For PCB isomers sub-pg/L range
Selectivity
Truly dissolved concentrations of hydrophobic compounds with Kow from 3 to 6
Repeatability
Variability of sampling rates of replicate EWL in the field is very small
Salinity range
no influenece
Electrical: no power requires
Mechanical: recommended mounting device and protective cage
EWL-PRC – Exposmeter Lipophilic for water with PRCs (performance reference compounds)
The EWL-PRC consists of a neutral, high molecular weight lipid such as triolein which is encased in a thin-walled lay flat polyethylene membrane tube.
Performance:
Detection level
Method specific. For PCB isomers sub-pg/L range
Selectivity
Truly dissolved concentrations of hydrophobic compounds with Kow from 3 to 6
Repeatability
Variability of sampling rates of replicate EWL-PRCs in the field is very small
Salinity range
no influenece
Electrical: no power requires
Mechanical: recommended mounting device and protective cage
EWL-Tox – Exposmeter Lipophilic Toxicity for water
The EWL-Tox consists of a neutral, high molecular weight lipid such as triolein which is encased in a thin-walled lay flat polyethylene membrane tube.
Performance:
Selectivity
Truly dissolved concentrations of hydrophobic compounds with Kow from 3 to 6
Repeatability
Variability of sampling rates of replicate EWL-Tox in the field is very small
Salinity range
no influenece
Electrical: no power requires
Mechanical: recommended mounting device and protective cage