Abstract
This paper discusses various particulate emission control strategies that can be employed for Municipal Solid Waste (MSW), Municipal Sewage Sludge, and Industrial Waste Incineration facilities. An example will be given of a particulate control installation that successfully cleans off-gases from an incinerator at a large photographic products plant.
Data supporting a theoretical model of Wet Electrostatic Precipitator (WESP) performance at a reduced flow will be presented. It is proposed this model could be used in adjusting EPA reporting parameters for reduced plant operation.