chemiluminescence Equipment available in Guam

Available in Guam| Near Guam
25 Results found

We couldn't find any chemiluminescence equipment in Guam

Here is a list of results available in Guam

Current filtering criteria

You can remove a filter by clicking on the x
  • Category: Air & Climate ×

  • Subcategory: Air Monitoring ×

  • Keyword: chemiluminescence ×

  • Available in: Asia & Middle East ×

  • Available in: Guam ×

Signal - Model 447 - Atmospheric NOx Analyser

by Signal Group Ltd     based in Camberley, UNITED KINGDOM

NOx analyser for ambient applications. Available in high sensitivity configuration. Optical permeation device for daily calibration checking.

Signal - Model StreetNOx - Reference Method System for Measuring NOx

by Signal Group Ltd     based in Camberley, UNITED KINGDOM

With the footprint of a telephone exchange cabinet the StreetNOx is a reference method system for measuring NOx by the roadside. It is available for measuring other gases such as SOx and can also be configured with a particulate monitor in addition to the NOx detector. Roadside ambient air quality monitoring system for NOx or any single gas ...

TAPI - Model T200 - Chemiluminescence NO/NO2/NOx Analyser

by Enviro Technology Services plc     based in Stroud, UNITED KINGDOM

The Model T200 NO/NO2/NOx analyser uses the proven chemiluminescence detection principle, coupled with state-ofthe-art electronics to allow accurate and dependable low level measurements for use as an ambient analyser or dilution CEMS monitor. A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while ...

Enviro - Model 600 Series - Chemiluminescent NO/NOx Digital Analyzer

by Enviro Technology Services plc     based in Stroud, UNITED KINGDOM

The California Analytical Instruments Model 600 CLD NO/NOx digital analyser is designed around a state-of-the-art 16-bit microprocessor. The 16 bit microprocessor control board consists of the MSR-Card with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyser can be manually operated from the keypad or ...

Model 600 CLD - Chemiluminescence Analyzers

by California Analytical Instruments, Inc. (CAI)     based in Orange, CALIFORNIA (USA)

The chemiluminescence method is used to measure the reaction between ozone and nitric oxide. In the NOx mode, the sample is routed through a converter. The resultant reaction is directly proportional to the total concentration of NOx. The reliability and rapid response time of CAI CLD analyzers make them particularly well-suited for the following ...

Model 600 HCLD - NO/NOx Chemiluminescent Analyzer

by California Analytical Instruments, Inc. (CAI)     based in Orange, CALIFORNIA (USA)

The California Analytical Instruments Model 600 HCLD NO/NOx digital analyzer is designed around a state-of-the-art 16-bit microprocessor. The 16 bit microprocessor control board consists of the MSR-Card with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyzer can be manually operated from the keypad or ...

Model 650 - Chemiluminescent NO/NOx & Paramagnetic Oxygen Analyzerr

by California Analytical Instruments, Inc. (CAI)     based in Orange, CALIFORNIA (USA)

The California Analytical Model 650 NOxygen NO/NOX/NO2/O2 digital analyzer is designed around a state-of-the-art 16 bit microprocessor, with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyzer can be manually operated from the keypad or remotely via TCP/IP, RS-232C communications and discrete inputs. The ...

MicroChemi - Model 2.0 - Chemiluminescence Systems

by biostep GmbH     based in Burkhardtsdorf, GERMANY

Chemiluminescence system; 1.9 MegaPixel. Ultra-sensitive system for chemiluminescence applications. maximum FOV 14 x 10cm. 

Celvin - Model S 160+ - Chemiluminescence Imager

by biostep GmbH     based in Burkhardtsdorf, GERMANY

Chemiluminescence Imager; 1.6 Mpixel. Ultra-sensitive system

KNESTEL CLD-flex-OEM - chemiluminescence detector

by KNESTEL Technologie & Elektronik GmbH     based in Hopferbach, GERMANY

CLD OEM modules from Knestel, the proven measurement procedures for trace gas analysis of nitrogen oxide emissions (NO / NOx) down to the ppb range.

Agilent - Model 8355 - Sulfur Chemiluminescence Detector

by Agilent Technologies, Inc.     based in Santa Clara, CALIFORNIA (USA)

The reimagined and redesigned Agilent 8355 SCD represents the first major advance in sulfur chemiluminescence detection in 25 years, making the technology more reliable and easier to use. Highly sensitive and highly specific, the reimagined detector is also easier to maintain, thanks to a simplified burner design with 50 percent fewer components. ...

Agilent - Model 8255 - Nitrogen Chemiluminescence Detector

by Agilent Technologies, Inc.     based in Santa Clara, CALIFORNIA (USA)

The Agilent 8255 Nitrogen Chemiluminescence Detector (NCD) is a nitrogen-specific detector that produces a linear and equimolar response to nitrogen compounds. This is accomplished by using a stainless steel burner to achieve high temperature combustion of nitrogen containing compounds to form nitric oxide (NO). A photomultiplier tube detects the ...

High-Performance Chemiluminescence Analyzer

by Tohoku Electronic Industrial Co.,Ltd.     based in Miyagi, JAPAN

Chemiluminescence analyzer(CLA) is one of the highest sensitive detectors. CLA can detect the ultra-weak light emission from various chemical reactions including those involving, oxidation, thermo-degradation, enzyme immuno assay (EIA) etc. CLA can follow the changes in samples right from the early stages of reaction with high sensitivity.

Altech - Model MIR 9000 - Multi-Gas Infra-Red GFC Analyzer (CLD- Chemiluminescence Option) System

by Altech Environment USA     based in Geneva, ILLINOIS (USA)

Sample dried and cleaned at probe using the SEC sampling system or with conventional sample conditioning. Microprocessor controlled. Dual ranges available. Analog and digital outputs. Meets or exceeds 40CFR60/75 requirements.

Luminometer, Portable

by Hach Company - a subsidiary of Danaher Corporation     based in Loveland, COLORADO (USA)

This luminometer is used with the ECLOX test kit for chemiluminescent toxicity testing.

Ecotech - Model Serinus 40 - Oxides of Nitrogen Analyser

by Ecotech Pty Ltd     based in Knoxfield, AUSTRALIA

The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL 0.4 ppb, range 0-20 ppm).

Ecotech - Model Serinus 60 - Direct Nitrogen Dioxide Analyser

by Ecotech Pty Ltd     based in Knoxfield, AUSTRALIA

Ecotech presents the latest addition to the Serinus range: The Serinus 60 NO₂ analyser with Cavity Attenuated Phase Shift (CAPS) spectroscopy technology. This technology allows direct measurement of nitrogen dioxide (NO2), rather than an indirect calculation from a chemiluminescence analyser. Using a modulated blue LED light source, the ...

Ecotech - Model Serinus 44 - NO/NO2/NOX/NH3 Multi Gas Analyzer

by Ecotech Pty Ltd     based in Knoxfield, AUSTRALIA

The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOxand NH3 in ambient air (LDL 0.4ppb, Range 0-20ppm). The Serinus range of analysers has been designed using our experience and knowledge gained from ...

ECO PHYSICS - Model CLD 63 Ox - Gas Analyzer

by ECO PHYSICS AG     based in Duernten, SWITZERLAND

Nitrogen oxide emissions need the oxygen content as reference. This is what the new analyzer CLD 63 Ox from ECO PHYSICS is made for: It measures both concentrations at once! Chemiluminescence and paramagnetic detectors - the standard reference methods.

Thermo-Scientific - Model 42i-HL - High Level Nitrogen Oxide Monitor

by Thermo Scientific - Air Quality Instruments     based in Franklin, MASSACHUSETTS (USA)

The Thermo Scientific™ Model 42i-HL is a chemiluminescent gas analyzer which measures nitrogen oxides (NO-NO2-NOx) in the emissions from a source. The Model 42i-HL is the industry standard for high level NOx Continuous Emissions Monitoring (CEM) systems and stack testing services. Using chemiluminescence technology, the Model 42i-HL measures ...

Need help finding the right suppliers?

Let the XPRTs do the work for you