Emissions Monitoring Equipment For Air And Climate In Kazakhstan
-
PremiumManufactured by OPSIS ABbased in SWEDEN
The System M800 is tested and approved by international test institutes and measures SO2, CO2 and NOx using the reference methods NDUV and NDIR. A light emitter and receiver creates a light path across the internal diameter of the stack. From the receiver, the light is guided in an optical fiber to the ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
The ER060L-EEx emitter and receiver set, together with Opsis LD500 laser diode gas analyser, is designed for gas monitoring in explosion classed areas Zone 1 and 2. The monitoring set creates a light path across the internal diameter of a stack or duct for an Opsis emissions monitoring system. Light is generated by the analyser, passed through the emitter and projected to the ...
-
Manufactured by Sintrol Oybased in FINLAND
The S305QAL stack emissions dust monitor meets the highest European standards as defined in EN14181. The S305QAL is approved for and is suitable for use on waste incineration and all combustion plant applications. The S305QAL1 comes with many key features making it a very reliable, low maintenance, sensitive and robust solution for stack measurements. Certified measuring ranges: 0…7.5 ...
-
Manufactured by Sintrol Oybased in FINLAND
TÜV certified to meet the EN 14181 (2004) standard, the S305 dust monitor is used for official emissions applications. The state of the art dust monitor has been used in stack emissions for a number of state owned and private industrial applications around the ...
-
Manufactured by Krohne Messtechnik GmbHbased in GERMANY
The OPTIBAR PT 2000 is an averaging pitot tube for applications with clean liquids, gases and steam. It is ideally suited for DP flow measurements requiring low pressure drop or cost-effective flow metering in extremely large pipes (up to DN20000 / 800"). Unlike conventional single-point pitot tubes that have the limitation of being a point-velocity device, the OPTIBAR PT 2000 averaging pitot ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS CEM systems measure multiple emissions or process gases in real time in situ. Using the DOAS (Differential Optical Absorption Spectroscopy) technique, the system is non-contact, with fast ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
System 400FL combines the benefits of hot wet extractive and in situ. The gas is moved at high speed in a bypass line. No filter or probe is used and the measurement takes place in a non-contact measurement ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS offers compact analyser packages for monitoring NOX, SO2, CO and O2 in many different kinds of stack gas ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS offers a wide range of shelter models and configurations to guarantee the optimal operation environment for your measurement equipment. We have experience in all environments, from hot and humid, to ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS System Shelters give the optimal operation environment for the measurement equipment. They are designed for OPSIS air quality monitoring systems, used for example for traffic monitoring, and industrial fugitive emissions monitoring. Various container models are available, depending on the application and the extent of the monitoring ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
System 400CS is a cost-effective, high-performance monitoring package, designed for power plants and waste to energy plants. The measurements are based on the FTIR (Fourier Transform Infrared Spectroscopy) and/or DOAS technique (Differential Optical Absorption Spectroscopy), allowing continuous monitoring of several compounds. ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
The OPSIS O2000 oxygen monitor is designed to monitor oxygen concentrations in industrial applications such as continuous emissions monitoring (CEM) and process control. It has been given a ruggedized design (IP65 protection) allowing it to operate under tough conditions in aggressive flue gas ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS offers a range of calibration equipment for use with its CEM and process control systems. The system is based on the CB100 calibration bench. This is used with an external CA150 light source, and with an RE060 receiver at each end of the bench itself. Calibration is carried out by inserting cells with transparent windows into the short light path. Calibration gases are flushed through the ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS data logger system is designed for data acquisition applications. The data logger can handle analogue and digital input and output signals as well as serial ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS LD500 Analyser is the central unit in the laser diode gas monitoring system. It can house up to four laser diode heads. Each head is a complete laser control and data sampling system. A built-in PC with LCD display controls the function of the ...
-
PremiumManufactured by Analytik Jena - an EndressHauser Companybased in GERMANY
Immobilisation of Nucleic Acids to Membranes. The UVP Crosslinker is a microprocessor controlled UV irradiation system dedicated to nucleic acid linking to membranes for Southern, Northern, Dot and Slot Blot applications. It can also be used for UV sterilisation and for elimination of PCR ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
Waste incinerators, cement plants and power plants need good and reliable measurements of total gaseous mercury. The measurement of total gaseous mercury (TGM) is a challenge due to chemical reactions and contamination. The installed systems will often require a lot of maintanence still not giving reliable ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
Our RD100 Real Driving Emissions system is an accurate and reliable monitoring system that can measure the emissions from car exhaust in real life conditions. The RD100 system is mounted on a car and measures the real driving emissions during an ordinary ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
Automatic gas calibration is available by using calibration gas and prefilled calibration cell. The gas cell is filled with a mixture of gases allowing all gases measured by the system to be checked. All data from gas calibration and automatic QAL 3 checks are stored in separate calibration data files, and are sent to the reporting software for ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS offers compact analyser packages for monitoring NOX, SO2, CO and O2 in many different kinds of stack gas ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you