Showing results for: stack emissions monitoring Articles
-
Gas standards relevant to stack emission measurements at the National Physical Laboratory
INTRODUCTION NPL is one of a number of laboratories which forms part of the Governments policy to ensure that UK measurements of all kinds are accurately made through the DTI’s National Measurement System. NPL is the focus of the United Kingdom’s physical measurements and its remit includes aspects of environmental measurements, which form an important component of the UK’s ...
-
Our past and our future
Measuring stack emissions has a long history. Our science, technology, needs, assumptions, and politics has dictated the directions we have gone. I will lay out the milestones of our past and look at why we went in our various directions. Then I will attempt to look into the future. The future can and probably will branch in several directions as it has in the past depending upon our future ...
-
Dust monitoring solutions for cement plants - Case Study
Particulate emissions from cement kilns have been reduced significantly over the last few decades due in part to ever-tightening regulatory controls including the lowering of emission limit values (ELVs) and the associated increase in installations of highly effective filtration systems which require higher quality monitoring. Main emissions to air are from the kiln system Additional ...
By ENVEA
-
Update on inclusion of manual stack emissions monitoring within MCERTS
ABSTRACT Proposals by the Environment Agency to extend its Monitoring Certification Scheme:MCERTS to manual stack emissions monitoring were published in June 1999. The proposals provide for the establishment of a Register of MCERTS qualified personnel and monitoring organisations. Registration would be based on third party certification of personnel and accreditation of monitoring organisations ...
-
Development of a real-time stack particulate mass monitor
Abstract Presently, particulate emissions from stacks are measured by sample and weigh methodology, which despite their status as ‘reference methods’ are often slow and sometimes not very repeatable. These methods use comparisons of before and after filter weighing to yield an average particulate concentration for a given sample period. The procedures require a great deal of care to ...
-
Utility Monitoring in a School Building
Universal Input Data Loggers Offer Total Building Solution A customer needed a utility monitoring solution to accurately monitor utility usage in a school building, totalized by floor. They needed to present this data in an easy-to-understand dashboard for each wing and as an aggregate total for the entire building. The client also had electric sub-panels on each floor, but they are separated ...
-
Emissions Testing
What Is Stack Emissions Testing? Stack emissions testing (stack sampling or stack monitoring) is the experimental process for evaluating the characteristics of waste gas stream emissions into the atmosphere from industrial facilities to meet environmental standards. Stack testing measures the amount of specific regulated pollutants or surrogates being emitted or determines the destruction or ...
-
The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe
POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...
-
Stack gas VOC monitoring
POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...
-
Process flue gas monitoring for combustion optimization - Case Study
Customer: Any industry having a stake in improved combustion technologies Material measured: Combustion flue gases Installation: At the boiler outlet Function: Reliable and accurate monitoring of O2 and CO for combustion control optimization Application Combustion has a number of outputs such as the ash and the emission to the atmosphere of flue gas. Before the flue gas cleaning system, ...
By ENVEA
-
In-situ continuous emissions monitoring & regulatory compliance
As environmental scrutiny has risen and regulation has tightened in recent years, the importance of having accurate information on the environmental performance of your power plant has increased. After all, if you want to manage something, you need to be able to measure it. The analogy is obvious; you wouldn't start a diet without first investing in a set of scales. So it is with Continuous ...
-
Abatement of solvent emissions and odors: online VOC monitoring
Industries concerned: Pharmaceutical Industry, Pesticides Producers, Iron and steel industry, Wood Industry, Plastic industry, Timber industry, Food industry, Paint, varnish and lacquer industry, Livestock industry, Cosmetics industry, etc. Volatile organic compounds (VOCs) are used in many professional sectors, particularly in industrial processes using solvents (paints, glues, varnishes, inks, ...
By ENVEA
-
Abatement of solvent emissions and odors: online VOC measurements
Industries concerned: Pharmaceutical Industry, Pesticides Producers, Iron and steel industry, Wood Industry, Plastic industry, Timber industry, Food industry, Paint, varnish and lacquer industry, Livestock industry, Cosmetics industry, etc. Volatile organic compounds (VOCs) are used in many professional sectors, particularly in industrial processes using solvents (paints, glues, varnishes, inks, ...
By ENVEA
-
Challenges for a Greener Future
The reduction of pollution impact is crucial nowadays, governments and industries are putting a big effort into this process and monitoring the air concentration of harmful compounds is a key point in achieving success. Environmental organizations around the world have set strict limits for all kinds of pollutants and many laws have been written in recent years in order to control emissions from ...
-
The Perfect Portable Tool for Stack Emissions Monitoring In Harsh Environment - Case Study
Excelair Ltd is a new organization located in Mauritius specialized in Air Monitoring Services. For the gaseous component of stack monitoring, Excelair has selected the ENVEA MIR 9000P to help them fulfill their on-site measurements. Mr. Krsn Ramiah, founder and Managing Director, tells us about the team’s field experience while using the portable multi-gas ...
By ENVEA
-
How Emissions Trading Scheme (ETS) Works to Reduce Air Pollution in India - Case Study
What is ETS? In the state of Gujarat, the Gujarat Pollution Control Board (GPCB) enforces pollution laws and regulations. GPCB sets a cap on the total emission load from all industries. In India’s War to fight against Air Pollution, GPCB has launched Emission Trading Scheme ...
By ENVEA
-
Free White Paper on FTIR Gas Analysis
Gasmet has prepared a White Paper on the simultaneous measurement of multiple gases in a wide variety of applications using FTIR (Fourier Transform InfraRed) technology. With the ability to measure almost any gas, FTIR monitoring technology is employed in an enormous variety of applications including Continuous Emissions Monitoring, Stack Testing, Process Control, Industrial Hygiene, Emergency / ...
-
Multi-compartment baghouse performance monitoring for reduced operating costs - Case Study
Industry Sector: Waste to Energy Material: Animal Waste (Combustion by product) Dust Loadings: Less than 10 mg/m3 Installation: 8 Individual Baghouse compartment outlets APPLICATION Waste to Energy Plants operate under strict particulate emission control limits, which typically requires the installation of multi-compartment baghouses. Providing a high degree of filtration efficiency, these ...
By ENVEA
-
White Paper & Video on FTIR multigas analysis
Gasmet Technologies has published a free White Paper and a video on the simultaneous measurement of multiple gases in a wide variety of applications using FTIR. Both the video and the White Paper can be found here at www.gasmet.com or by visiting the Quantitech stand 62/63 at AQE 2017. With the ability to measure almost any gas, FTIR technology is employed in an enormous variety of applications ...
-
Stack emission monitoring – TOC determination - Case study
Over the past decade enormous scientific, social and economic changes have impacted our quality and environmental regulations, prompting a new look at the subject of controlling emissions of Volatile Organic Compounds (VOCs). Problem: VOC emissions are quantified and monitored according to standard EN 12619, using Flame Ionization Detectors (FID) analyser which uses hydrogen and other reference ...