voc calibration Articles

  • A Guide to BFB Tuning for VOC Analysis

    All US EPA methods for volatile organic compounds (VOCs) require that specific GCMS tuning criteria be met before running a calibration curve or analyzing actual samples. The GCMS is tuned using the traditional tuning compound, PFTBA (perfluorotributylamine), and the tune is evaluated every 12 hours by injecting BFB (4-bromofluorobenzene) and measuring the relative intensity of key mass ...

  • Case study : VOC analysis in ambient air by FID dectection - Complete system airmOzone

    Ozone concentration has been multiplied by 5 in the last century in the middle latitudes of the northern hemisphere from 10 PPB in 1874 to approximately 50 PPB today. This is an increase of 1.6% per year; the trend is probably higher (2.4% a year) over the last decades. (Chapter 1 of the International Geosphere-Biosphere Program - World Climate Research Program) In order to stop this global ...


    By Chromatotec Group

  • Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas

    This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO2 and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three ...


    By Ogawa & Company, USA, Inc.

  • NASA campaign KORUS-AQ: IONICON PTR-TOF to monitor VOCs above Korea

    Team of the University of Innsbruck and an IONICON PTR-TOFMS aboard NASA research aircraft An international team coordinated by NASA has recently investigated air pollution over the Korean peninsula. Two of IONICON’s PTR-TOFMS instruments were used to monitor volatile organic compounds (VOCs) in real-time aboard NASA’s DC-8 Flying Laboratory. The data gathered by scientists ...


    By Ionicon Analytik Ges.m.b.H.

  • Validation of USEPA Method 524.2 Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

    The US EPA developed Method 524.2¹, “Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry”, for identifying and measuring purgeable volatile organic compounds (VOC) in surface water, groundwater, and drinking water. Due to the required sensitivity of this method, the use of purge and trap gas chromatography is vital. This ...


    By Teledyne Tekmar

  • Shimadzu Guide to US EPA Method 8260 for analysis of volatile organic compounds in groundwater and solid waste

    Environmental contamination has been at the forefront of government policy and regulation since the US EPA was established in 1970. Over the years the US EPA has developed, published, and updated multiple methods for analysis of environmental pollutants, and single-quadrupole gas chromatography-mass spectrometry (GC/MS) has long been the technique of choice for determination of volatile ...

  • airmoTWA: New Expert System for GC-FID/MS

    Chromatotec has developed the first TRAP-GC-FID/MS designed for continuous monitoring of Volatile Organic Compounds (VOCs), inorganic molecules and permanent gases. In addition to the mass spectrometer (MS), this system encompasses the same trap, thermo desorption and separation technologies as airmoVOC analyzers (current mCERTS approved GCs analyzers). For VOCs analysis, the Flame Ionization ...


    By Chromatotec Group

  • Are your field soil screening procedures providing you with practical and accurate information?

    Untitled Document Environmental consulting activities frequently require that on-the-spot decisions be made in the field concerning the ...


    By Enviro-Equipment, Inc.

  • Building on a legacy of PID development

    Summary From the 1970s to the present day, photo-ionisation detectors (PIDs) have been at the front line of efforts to detect volatile organic compounds. As industrial hygiene has become ever more important and exposure limits for VOCs have reduced, PID technology has continued to develop, providing reliable detection under challenging environmental conditions at concentrations right down to ...


    By Ion Science

  • The MACT for petroleum refinery FCCs is a fraud!

    This paper is a continuation of the author's research on the MACT regulation for abating pollution from Petroleum Refinery FCCs in the US. This paper highlights the flaws in the recently promulgated MACT for NSPS and non-NSPS FCC units. It details the inadequacies and the potential for perversity in the New Source Performance Standards (NSPS) that are an integral part of the FCC MACT. It ...


    By Inderscience Publishers

  • TVOC measurement for LEED/green building evaluation

    Total Volatile Organic Compounds (TVOC) may be evaluated when building designers/managers are pursuing the Leadership in Energy and Environmental Design Green Building Rating System for New Construction (LEED-NC) EQ Credit 3.2. The latest LEED-NC guidance document specifies that the maximum allowed concentration of TVOC measured in a building (post construction, pre-occupancy) is 500 µg/m3; the ...


  • Field Detection of Chlorinated Alkenes in Well Water using the FROG-4000 Portable GC - Case Study

    Introduction Defiant’s FROG 4000, a portable GCPID system, was used to identify and determine the concentration of chlorinated alkenes in several extraction wells located in Tacoma Washington. Split samples were taken at each well and sent to an offsite lab for analysis. This case study examines the field exercise and highlights the high degree of agreement between the offsite lab and ...


    By Northern ANI Solutions Ltd.

  • Setting the standards for headspace sampling by PID

    The responsiveness of PIDs to virtually all VOCs has seen them become the accepted tool for initial site entry assessment, ensuring optimal detection of unknown and often toxic or hazardous chemicals found at hazardous waste sites and chemical emergencies. The speed and accuracy of modern PID equipment means that many worker and community safety concerns during initial and ongoing operations can ...


    By Ion Science

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you