Air purification & filtration solutions for the healthcare & Lab industry - Health Care

The OmniAire HEPA negative air machines and OmniAire PAC Portable Air Cleaners can be used to create positive and negative pressure isolation rooms, first response areas, increase number of air changes per hour (ACH) and to purify the air in gathering areas.. Our machines are equipped with HEPA filters, UV-C germicidal lights and an optional PEROx, a Hydro-Peroxide air purifier module for the highest degree of purification of air and surrounding surfaces. To monitor the patients room pressure relative to pressure in corridors to prevent any cross-contamination, the Watchman differential pressure monitor or Omniguard 4 differential pressure recorder can be used.

Negative Pressure Environment

The CDC recommends an Airborne Infection Isolation (AII) for the patients with infectious diseases such as smallpox (variola major), mucobacterium tuberculosis (TB), SARS, airborne viral diseases (VZV), measles (Rubeola) and mucorales. Current CDC guidelines recommend negative pressure rooms with an anteroom for AII rooms. The negative pressure room should have 0.020” W.C. lower pressure than the attached corridors. The OmniAire machine is used to purify air from the isolation room before it is exhausted in surrounding corridors or outdoors.

Positive Pressure Environment


To create a clean room environment for hyper-sensitive patients, the room can be positively pressurized with clean, sterile air to prevent bio-contaminants to migrate into the room. This protective environment is recommended for HIV patients, bone marrow transplant, ICU rooms, diabetes patients, cancer patients, stem cell transplants and other high risk patients. Recommended by CDC, the positive pressure room should have at least 0.010” W.C. higher pressure than the attached corridors. The OmniAire PAC combines several stages of air purification to assure the highest purity of supplied air to positively pressurize the isolation room.

Patient Room Cleanup – Turnaround Time
We are concerned with providing the highest levels of protection for hospital workers and patients. After hospital cleaning staff carry out infectious disease control cleanup procedures (the removal of all physical items) in the infected areas, the room can then be put back in service faster if the air is purified and sterilized using an OmniAire PAC Portable Air Cleaner with high output PEROx air purifier module.xide plasma generator. This results in minimal room shut down and disruption which is a major concern for all hospital administrations.

OmniAire Equipment for Laboratory Environments


Omnitec has over 20 years of experience in the manufacture and deployment of portable air filtration equipment to a wide range of applications in medical facilities, laboratory environments, and hazardous waste control. Our line of OmniAire and OmniAire PAC HEPA air filtration machines with airflows from 50 cfm to 2000 cfm, we can help you to solve almost any air purification issues.

Applications

  • HEPA filtration of hazardous contaminants from flow benches with sealed HEPA for ease of disposal.
  • HEPA and Activated Carbon filtration of dust and fumes
  • Creating positive or negative pressure environments
  • Increasing air changes (ACH) and purifying air where needed

Differential Pressure Monitors

The positive pressure required at Clean Room work area is usually at 0.010” to 0.020″WC which is very hard to measure with any accuracy. The Watchman differential pressure monitor and Omniguard 4 pressure recorder provide an accurate monitoring and alarming functions. They are easy to setup with a simple pushbutton calibration and a tubing connection.

Maintenance and Renovation Projects in Medical Facilities
CDC requires isolating and containing airborne dust and pathogens during any type of maintenance of the facility. It includes cutting into walls, floor, removing ceiling tiles and even replacing fluorescent light tubes. The OmniAire HEPA air filtration machines are your best tools for effective Infection Control during renovation and maintenance projects. Our HEPA air scrubbers and negative air machines are used on thousands of such projects every year by maintenance department and contractors.


To kill and deactivate bio-contaminants, VOCs, odor, chemical fumes and many viruses and bacteria, PEROx, a Hydro-peroxide purifier can be added to our OmniAire HEPA negative air machines

Usual projects include:

  • Renovation and Construction Dust
  • Paint and Varnish Odors
  • Toxic Mold Remediation
  • Fungus Remediation
  • Asbestos Removal and Abatement
  • Lead Paint Abatement

Differential Pressure Monitors

The positive pressure required at Clean Room work area is usually at 0.010” to 0.020″WC which is very hard to measure with any accuracy. The Watchman differential pressure monitor and Omniguard 4 pressure recorder provide an accurate monitoring and alarming functions. They are easy to setup with a simple pushbutton calibration and a tubing connection.