Only show results available in Virginia? Ok

activated sludge treatment Applications

  • Ozone Water Treatment for Activated Sludge Process Plants

    Ozone breaks up filaments and improves settling characteristics of the sludge... Filamentous sludge is a common problem at activated sludge plants. With ozonation of the return sludge flow it is possible to reduced the amount of filamentous bacteria in the sludge and significantly increased the settling properties of the sludge.This in turn means better performance of the activated sludge process. When a bioreactor is connected to the sludge line the removal of the damaging filamentous bacteria means higher quality sludge in the bioreactor, which leads to higher biogas production.

    By Primozone Production AB based in Löddeköpinge, SWEDEN.

  • Waste water respirometry solutions for monitoring activated sludge health - sour test

    Respiration rate monitoring of Antwerp treatment works showed periods when the activated sludge was up to 40% inhibited, with resultant sludge washout episodes. Using the Health monitoring test, a pattern of ‘normal’ respiration rates for a plant can be determined. Lower respiration rates will alert the treatment works to a chronic toxicity problem, allowing corrective actions to be taken. Toxicity monitoring can now be carried out on a routine daily basis, at all treatment works receiving potentially toxic wastewaters. This is especially important if there has been a history of poor plant performance.

    By Strathkelvin Instruments Ltd. based in North Lanarkshire, UNITED KINGDOM.

  • Premium

    Dosing pumps for water and wastewater treatment industry

    Peristaltic pumps are proven performers in water and waste treatment solving problems including: Dosing and metering treatment chemicals and reagents including ferric chloride (“Ferric”), sodium hypochlorite (“Hypo”), chlorine water, lime (Kalic or Kalkmilch), caustic soda, powder activated carbon and polymers, sludge transfer, filter press feeds.

    By Verderflex Peristaltic Pumps - part of the Verder Group based in Castleford, UNITED KINGDOM.

  • Biological waste water treatment

    Biological waste water treatment - activated sludge systems - biofilm systems - submerged fixed film system - MBBR-Systems - MBR-Systems - SBR Systems

    By Environmental Engineering Doellerer GmbH based in Seefeld, GERMANY.

  • Premium

    Albin peristaltic`s pumps for water treatment

    Pumping / transfert / dosing of sewage thickened, sludge dewatered, sludge clarifier, waste activated sludge, digested sludge, primary sludge, lime milk, raw sludge, sodium hypochlorite, ferric chloride, sodium bisulphite, fluoride, polymers, aqueous am­monia, potassium permanganate, caustic soda.

    By Albin Pump SAS based in Goteborg, SWEDEN.

  • Premium

    Treatment, Optimization and Design for WWTP's

    The purpose of the work is to demonstrate the rationale, procedures and advantages of using process simulation to evaluate the steps involved in process upgrades from conventional or fully aerobic process conditions to multi stage systems capable of operating as a BNR system. In the author's experience and the conclusions of this presentation are that the use of these systems in daily operations and in the preparation for process upgrading is empowering and economically advantageous. SASSPRO(Steady State Activated Sludge Simulator, Program)

    By WeDoTanks.com LLC based in Sahuarita, ARIZONA (USA).

  • Fat, Oil and Grease treatment

    Industrial and municipal waste contaminated with fat – a frequent problem for companies maintaining wastewater network infrastructure and municipal wastewater treatment facilities. We recommend the use of GREASOLUX fat dissolvent cartridges to avoid the problems of pipeline chocking, equipment damage, offensive odors, formation of filamentous bacteria, poor wastewater treatment results, poor sedimental properties of activated sludge. GREASOLUX – is a cartridge that slowly dissolves in water, enriched with special fat dissolvent microorganisms and enzymes. GREASOLUX – is an especially efficient product for low cost solutions to problems caused by fat: only few strategically placed cartridges will remove or minimize the problems caused by fat.

    By Ecochemicals UAB based in Kaunas, LITHUANIA.

  • Premium

    Real-time Control System for Wastewater Treatment Plants

    Wastewater treatment plants (WWTP) are subject to large variation in flow and load, not to speak of uncertainties on the composition of the incoming wastewater. On top of that, the activated sludge treatment process, as used by the vast majority of treatment plants, is difficult to control due to the complex behaviour of the biological process. Nevertheless WWTPs are run 24/7, with operators and management challenged to meet ever tightening environmental regulations.

    In order to meet the operational demands of modern-day plants, a new control system was developed. Proprietary control algorithms were introduced based on a large set of data from nutrient measurements in various WWTPs. The customer`s benefits are twofold: (1) achieving optimum effuent quality and, at th same time, (2) lowering energy needs and dosing of commidity chemicals.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Removal of organic compounds & toxity for wastewater treatment industry

    Federal and State regulatory agencies are increasingly requiring additional water quality testing and controls of the toxicity of discharges to receiving streams. Granular Activated Carbon (GAC) helps meet these pollution regulations. If organic chemicals have been identified as contributing to discharge toxicity, Calgon Carbon Corporation can work with facilities, and their engineering firms, to help meet stringent criteria associated with their NPDES permit. GAC can be employed as a cost-effective treatment for removal of organic compounds and toxicity. Even in situations where activated sludge treatment or powdered activated carbon is used for primary wastewater treatment, post treatment with GAC may be necessary to achieve toxicity compliance.

    By Calgon Carbon Corporation based in Pittsburgh, PENNSYLVANIA (USA).

  • Filamentous Bulking Control with Hydrogen Peroxide

    Basis of Control with Hydrogen Peroxide Hydrogen peroxide may be used to correct a serious filamentous bulking situation or, preferably, to prevent one from occurring until adjustments can be made to remove the cause. When applied to the return activated sludge, hydrogen peroxide supplies dissolved oxygen which helps restore the microbial activity necessary for effective operation, while selectively oxidizing the filaments which retard settling. The effective dose of hydrogen peroxide is a function of time and concentration, and varies from plant to plant. To correct a serious bulking problem, immediate results may be obtained by adding 100 - 200 mg/L H2O2 to the biosolids recycle line. Once control of bulking is obtained, the dose may be reduced to 25 - 50 mg/L H2O2 to prevent re-occurrence. Practical Considerations Filamentous bulking of municipal activated sludge is not a normal occurrence, and suggests more fundamental problems may be at work (e.g., low dissolved oxygen, high sulfide input, heavy organic loading, nutrient imbalance, improper sludge age, or rapid changes in influent characteristics). Consequently, the use of chemicals such as hydrogen peroxide to control bulking should be pursued in concurrently with more fundamental corrective measures.

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).

  • Headworks Odor and Corrosion Control Using Hydrogen Peroxide

    Hydrogen Peroxide typically controls odors and corrosion at treatment plant headworks by direct oxidation of hydrogen sulfide (H2S) within the wastewater. In the direct oxidation mode, H2O2 is applied to the wastewater 5-30 minutes prior to the point where the odors are being released, generally as the wastewater line enters the plant boundary. The efficiency of hydrogen peroxide treatment depends upon the available reaction time, the level of iron in the wastewater (reaction catalyst), wastewater pH and temperature, and the initial and target levels of H2S odor. Under optimal conditions, effective dose ratios are 1.2 - 1.5 parts H2O2 per part dissolved sulfide, and can be reliably estimated through beaker tests. H2O2 + H2S → S0 + 2H2O Frequently, control of odors through the primary clarifiers is wanted. In such case, the mechanism of control is both direct oxidation of H2S (as it rises from the solids blanket), and prevention of odor generation (by supplying dissolved oxygen). Control is typically achieved with a booster dose of 1-2 mg/L H2O2 added to the clarifier influent. Higher doses or alternate modes of addition may be required in cases where: 1) hydraulic retention times are > 2-3 hours; 2) solids blanket depths are > 1-2 feet; 3) soluble BOD levels are > 200-300 mg/L; or 4) waste activated sludge is co-settled with the primary solids. 2H2O2 → O2 + 2H2O

    By USP Technologies based in Atlanta, GEORGIA (US) (USA).

  • Remedial Construction for Mining and Metals

    ENTACT is the industry leader in the management and treatment of heavy metal impacted soil, sludge, and debris. Approximately half of the projects we have completed over the past 21 years have involved metals. These projects have included soil and sediment removal, residential cleanups, smelter closures, earthwork/mine reclamation, and decontamination and demolition of mine and mill structures at both active and abandoned facilities. ENTACT holds seven patents related to treatment of heavy metal impacted materials.

    By ENTACT, LLC based in Grapevine, TEXAS (USA).

  • Waste water respirometry solutions for toxicity tracking

    If toxicity is identified in a mixed sewage entering a treatment works, the problem for the plant manager is to track and identify the source of the toxicity. This can be done by sampling the effluent stream at various points in its length. By working in a logical sequence back up the sewer network the number of samples can be minimised. This type of testing should be rigorously enforced for new product introduction by a waste producer, as well as sampling the effluents directly at source. The samples would be tested against the activated sludge of the receiving works, using the Respiration Inhibition Test or the Nitrification Inhibition Test.

    By Strathkelvin Instruments Ltd. based in North Lanarkshire, UNITED KINGDOM.

  • Waste water respirometry solutions for toxicity based consents

    Water companies, water authorities or publicly-owned treatment works (POTW) need to have some knowledge of the composition of the wastes they it receive. In addition to testing for ammonia and BOD or COD levels, treatment works can license industrial discharges on the basis of concentrations of some of the known toxic compounds. However, it is recognised that very many non-regulated toxic materials still enter the treatment works and reduce the efficiency of biodegradation, and may cause toxic shock. The way is now open for more widespread use of direct toxicity tests as a basis for toxicity-based consents. Samples of the industrial effluent are collected at source, for testing on the actual bacteria of the receiving activated sludge. The tests used are the Respiration Inhibition Test and the Nitrification Inhibition Test. Note that this approach mirrors that of the regulators of discharges to receiving waters, who are now using direct toxicity tests (DTA) or whole effluent toxicity tests (WET tests) in order to protect the receiving environment.

    By Strathkelvin Instruments Ltd. based in Motherwell, UNITED KINGDOM.

  • Waste water respirometry solutions for toxicity reduction tests

    In industrial manufacturing companies, before a new process comes on-line, it is important to measure the toxicity of the effluent stream. This is especially the case for companies who treat their own waste. From the toxicity value (EC50) obtained, it may be a cost-effective solution to simply discharge the effluent to the treatment works at a slow and defined rate to minimise damage to the activated sludge. Following a period of acclimatisation it is often possible to increase feed rates to the plant and this can again be managed using the Strathtox Respirometer. An alternative approach is to undertake toxicity reduction procedures, such as neutralisation or acid hydrolysis, in pilot-scale laboratory studies. The Respiration or the Nitrification Inhibition Test may be used for this. In the future, toxicity reduction may be stipulated by local authority, water company or publicly-owned treatment works prior to giving discharge consents. Toxicity reduction may be evaluated using toxicity tests on activated sludge provided by the treatment works.

    By Strathkelvin Instruments Ltd. based in North Lanarkshire, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you