Only show results available in Virginia? Ok

air analytical method Applications

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B Performance Specification 15. Gasmet™ Gas Analyzers and Calcmet™ software have been designed to take the requirements of the performance specification into account.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

  • Premium

    Analysis of Isocyanates Using the ASSETâ„¢ EZ4-NCO Dry Sampler

    Isocyanates are used as a raw material to produce a number of products . Personal exposure can occur while the products made with isocyanates are being applied, or when the materials are removed by grinding or thermal degradation. Workers who are exposed to these compounds are at risk for respiratory disorders and asthma. The highly reactive nature of the isocyanate compounds and the low occupational exposure limits put high demands on both sampling and analytical techniques for monitoring of isocyanates in air. We investigated the performance of the LC-MS and LC-MS-MS methods in the analysis of isocyanates using the new ASSETâ„¢ EZ4-NCO Dry Sampler. We found that the analytical method can successfully reach the quantitation limit for most isocyanates of 5 ng/mL in the final sample when LC-MS-MS analysis was used and the quantitation limit of 10 ng/mL when LC-MS analysis was used. All 11 compounds were well-resolved chromatographically using a 15 cm Ascentis Express C18 column.

    By Sigma-Aldrich Co., LLC based in Bellefonte, PENNSYLVANIA (USA).

  • Chromatography systems for environmental monitoring

    With the growth of contamination generated from agricultural and industrial production, it causes a threat to the enviroment including drinking water, atmosphere and soil. The chemists have always seeked out the effective analytical methods to detect and identify chemical contaminants. Dikma provides innovative products and application solutions according to government regulations and industry standards, for air and water quality monitoring, gas detection.

    By Dikma Technologies Inc. based in Lake Forest, CALIFORNIA (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you