air flow measurement Applications

19 Results found
Only show results available in Virginia?
OK
  • Keyword: air flow measurement ×

Flow meters for steam measurement solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

As an innovative steam flow meter manufacturer, Sierra’s InnovaMass brand was the first multivariable mass vortex flow meter to launch to market in the late 1990s. Today our flow meter steam technology is successfully used across numerous applications. Sierra`s multivariable product line features an in-line version, the InnovaMass 240 vortex flow meter; a unique immersible version, the InnovaMass 241; and the InnovaMass cryogenic version.

Flare gas measurement flow for solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Our flow meters are used throughout the oil patch, from monitoring injection at the wellhead and measuring natural gas for heaters and boilers to measuring the various process gases at the refinery or flared in the field.

Flow Measurement instrumentation for digital flow meter air measurement solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

From heavy industrial to research and analytical applications, Sierra has a wide range of digital air flow meters and controllers with digital output protocols. Sierra offers digital gas flow meters and mass flow meters across two core technologies: Capillary Thermal, and Immersible Thermal.

Secundary air flow measurement for power generation industry

by Kurz Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Secondary Air Flow Overview: The need for accurate, repeatable & reliable combustion air measurements in power generation plants is critical to efficient operation and safety throughout the entire facility and processes. Accurate secondary air flow measurement to the burners is critical for maintaining the proper air to fuel ratio, result­ing in more complete and stable combustion, better performance and lower emissions. Coal-fired power plant applications pose a number of challenges to obtaining these critical flow measurements including large ducts, limited metering runs, poor velocity and temperature profiles, vibration and high temperatures.

Compressed air measurement & control flow solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Compressed air isn`t free, so more and more companies carefully monitor its usage. Thermal flow meters are ideal for this application. Because our thermal flow meters measure mass flow directly, no temperature or pressure compensation is required. Thermal flow meters also have a very high turndown, allowing the same flow meter to measure very low leak rates as well as full operational flows.

Carbon dioxide mass flow meters flow solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Thermal mass flowmeters are ideal for Carbon Dioxide metering and mass flow control. Sierra specializes in accurate mass flow measurement and/or control of CO2 gas. Applications range from general industrial process control across numerous industries to Green House Gas monitoring requirements and general research.

Facilities management in line air flow meter solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Sierra’s offers a complete line of precision flow solutions for any gas, liquid or steam measurement to improve energy efficiency in all facilities management applications. Our mass vortex meters are used to allocate steam, our in line thermal mass flow meters track and allocate natural gas and compressed air usage, and our clamp-on and insertion ultrasonic meters provide accurate water and water-based fluid measurement.

Flow measurement instrumentation for waste water treatment flow solutions

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

With its high turndown and direct mass flow, our immersible thermal meters are the instrument of choice for measuring aeration basin air flow and monitoring digester gas. Our vortex meters are used to measure steam in the cogeneration processes, while our ultrasonic flowmeters are used for influent and effluent measurement.

Testing Fume Hood Flow Dynamics using SF6 as a Tracer Gas

by Spectro Scientific     based in Chelmsford, MASSACHUSETTS (USA)

A safe laboratory environment requires an effective method for clearing toxic material from fume hoods. Since all handling of toxic materials is completed in these hoods, it is critical to have a procedure to evaluate their operation to assure adequate protection for laboratory workers. The InfraRan Specific Vapor Analyzer, factory calibrated for SF6, is an ideal instrument for measuring fume hood efficiency in accordance with ASHRAE and other standards. Manufacturers identify the flow dynamics (factors that affect air flow in the hood and performance with air) using the ratings AM (as manufactured), AI (as installed), and AU (as used). A fume hood evaluation conducted under its operational environment is critical, as these tests will indicate any installation shortcomings as well as direct workers in proper laboratory hood techniques.

Mercury monitoring for mercury flux measurement

by Tekran Instruments Corporation     based in Knoxville, TENNESSEE (USA)

The Tekran 2537 has been used in numerous published studies to measure the deposition or evasion of mercury from natural or contaminated surfaces (i.e. flux measurements). It is anticipated that many mercury flux measurements will be needed in the future to assess the impact of climate change on mercury cycling in the environment. There are two basic ways to do mercury flux measurements. First, the dynamic flux chamber method utilizes a custom enclosure, with controlled air flow, to measure the inlet and outlet concentration over a selected surface to determine the flux over time. Alternatively, the micrometeorological gradient method uses measured concentrations at two levels above a surface. The perfect tool for both flux measurement methods is the Tekran 1110 Two Port Sampler, so the Tekran 2537 can automatically switch between two distinct sampling points. Ask us how we can help you setup a mercury flux system.

Gas measurement for the pulp & paper industry

by Kurz Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

The Kurz Insertion Mass Flow Meter products provide extremely reliable and accurate measurements for the harsh environment of a recovery boiler facility, without restricting airflow even in short run ducts.

Flow meters solutions for developing economies

by Sierra Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Mass flow meters and mass flow controllers help developing countries explore their natural resources. Our thermal flow meters are widely used in flotation cells in mining. Our multivariable mass vortex flow meters are used in the oil and gas industry both at the wellhead and in the refinery. Thermal mass flow meters also have a place in the power generation industry where they are used to measure and control fuel-to-fuel air ratios.

Raw-gas monitoring for scrubber optimizing

by Opsis AB     based in Furulund, SWEDEN

The consumption of scrubbing material in a scrubber is related to the mass flow of acid gases. Hydrogen chloride (HCl) and sulphur dioxide (SO2) are the major acid gases in an incinerator. By measuring the mass flow of SO2 and HCl in the raw gas going into the scrubber, it is possible to calculate the required quantity of scrubbing material.

Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

by Environnement S.A     based in Poissy, FRANCE

With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

Primary air control for coal-fired power plants

by Kurz Instruments, Inc.     based in Monterey, CALIFORNIA (USA)

Power Generation Combustion Air Measurements: The need for accurate, repeatable & reliable combustion air measurements in power generation plants is critical to efficient operation and safety throughout the entire facility and processes. Coal-fired power plant applications pose a number of challenges to obtaining these critical flow measurements includ¬ing large ducts, limited metering runs, poor velocity and temperature profiles, high vibration, temperatures up to 750° F and dirty `Fly Ash` laden air.

Stack Testing for Power Generation Plants

by AirSource Technologies, Inc.     based in Shawnee, KANSAS (USA)

POWER GENERATION INDUSTRY: Conducted detailed measurements of volumetric flow, oxygen, and carbon dioxide levels in huge main ducts in the Economizer Outlet, Air Heater Inlet, and Exhaust Stack locations in order to evaluate overall plant and control system performance

Emissions testing for industrial boilers and burners

by Testo Inc.     based in Sparta, NEW JERSEY (USA)

Industrial boilers and burners have their own unique characteristics. When an unexpectedly high CO is detected, the Testo 350 will automatically adjust to the situation, keeping the sensor protected at all times. Don`t worry about climbing and removing the probe from the stack, just hit the fresh air button. The measurements of O2, CO, NO and SO2, combined with automatic calculations (CO2, efficiency, excess air), provide fast tuning solutions. The 350`s compact design is better for working on a platform or small space. The automatic zero pressure measurement is ideal to monitor flow or draft induction. With a pitot tube you can quickly measure velocity and determine mass flow even during long term testing. The Testo 350 makes reporting in lbs/hour easy!

Need help finding the right suppliers?

Let the XPRTs do the work for you