air leak detection Applications

10 Results found
Only show results available in Virginia?
OK
  • Keyword: air leak detection ×

Portable Leak Detection

by Boreal Laser Inc.     based in Edmonton, ALBERTA (CANADA)

GasFinder2 can be used as a portable open path gas sensor to survey a large site relatively quickly. Areas of elevated gas concentration can be bracketed using shorter path lengths in order to locate leaking valves, flanges or fittings.

Gas Detection Solutions for Liquified Natural Gas Detection

by Boreal Laser Inc.     based in Edmonton, ALBERTA (CANADA)

Liquefied natural gas owners require improved routine monitoring of facilities for safety, economic and regulatory reasons. Leaking LNG can cause explosions leading to loss of life and property. Loss of product through undetected leaks dramatically reduces a pipeline operator’s profitability. Traditional gas detectors are slow to reach and require a labour intensive process to keep maintained. IR detectors have been used but with limited success because of cross interference from other atmospheric gases.

Gas Detection Solutions for GHG Monitoring

by Boreal Laser Inc.     based in Edmonton, ALBERTA (CANADA)

Most sources of fugitive emissions are from multiple points rather than single point sources. So, open path area or perimeter monitoring provides more meaningful fugitive emissions data than an array of point sensors or a program of grab sampling. Point measurements may underestimate emissions because of missing locations with high gas concentrations, or conversely overestimate because they are located in areas of high concentrations. Grab sampling programs typically check only a small percentage of potential leak locations and extrapolate results to an entire facility. Wide margins of uncertainty are associated with such extrapolations. Open path monitoring provides continuously updated, real-time, integrated emissions across a facility boundary.This provides a complete picture of the fugitive emissions across that boundary,enabling identification of specific operations and times that give rise to higher emissions, and so enabling these emissions to be properly managed and controlled.

Perimeter Ambient Air Monitoring

by Cerex Monitoring Solutions, LLC.     based in Atlanta, GEORGIA (US) (USA)

Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring. Cerex multi-gas analyzers offer significant advantages over single gas analyzer arrays, electro-chemical sensor arrays and time integrated air sampling hardware

Open Path Ambient Air Quality Monitoring

by Cerex Monitoring Solutions, LLC.     based in Atlanta, GEORGIA (US) (USA)

Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring.

Single Gas Monitoring - Open Path Monitoring

by Boreal Laser Inc.     based in Edmonton, ALBERTA (CANADA)

Application: measurements of single gas species through a fixed open air sample path. Example: HF leak detection in refinery HF Alkylation units.

Smoke generator device for building envelope, energy studies & air tightness testing

by Concept Smoke Systems     based in Maidenhead, UNITED KINGDOM

The air tightness or leakage rate of a building is the uncontrolled flow of air through holes, gaps and cracks in the fabric of a building, which may not be detectable simply by looking at the outside of the building. Filling a building or void with smoke and pressurising that volume, will result in a visible discharge of smoke from any problem areas. Smoke is the perfect medium for discovering where leaks are and how big they are! Filling a `leaky` building, ductwork, pipes, aircraft or containment area with smoke and ideally adding a small amount of pressure to the area being tested, will result in a visible discharge of smoke and, simply put, the greater the volume of smoke, the bigger the leak.

Gas monitoring instruments and systems for phosgene monitoring

by Gasmet Technologies Oy     based in Helsinki, FINLAND

Phosgene COCl2 is a colorless gas. While it has been used as a Chemical Weapon Agent (CWA) in the past, currently this poisonous gas is also an important reagent in synthesis in the pharmaceutical and chemical industries. The plants using phosgene are typically equipped with gas sensors to detect leaks in the indoor ambient air. The critical situations arise when equipment in contact with the gas at the manufacturing facilities are serviced and maintained. As phosgene is very poisonous, even small gas pockets in serviced equipment may be dangerous to maintenance personnel. Gasmet™ FTIR Gas Analyzers are ideal tools to monitor point sources of phosgene. The measurement technology has high specificity, may be operated continuously, and has a fast response time.

Fence-Line Monitoring of Fugitive Emissions

by Opsis AB     based in Furulund, SWEDEN

The Opsis open path monitoring system is an excellent tool for monitoring air quality, fugitive emissions and gas leaks at industrial sites. By arranging monitoring paths strategically at locations outside the borderline of an industrial area, fugitive emissions and gas leaks will effectively be detected. By combining the measured gas data with meteorological parameters information such as where the pollution sources are located and the strength of the emissions can be calculated, using the EnviMan software.

Fence-line Monitoring

by Opsis AB     based in Furulund, SWEDEN

The OPSIS open-path monitoring system is an excellent tool for monitoring the air quality, fugitive emissions and gas leaks at industrial sites. By arranging monitoring paths strategically at locations outside the borderline of an industrial area, fugitive emissions and gas leaks will effectively be detected. By combining the measured gas data with meteorological parameters information such as where the pollution sources are located and the strength of the emissions can be calculated, using the EnviMan software.

Related Terms for air leak detection

Need help finding the right suppliers?

Let the XPRTs do the work for you