Only show results available in Virginia? Ok

air pollution monitoring instrumentation Applications

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to...

    By ENVEA based in Poissy, FRANCE.

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Air quality and industrial gas monitoring systems for Ambient air monitoring

    Ambient air quality monitoring is the systematic, long-term assessment of pollutant levels by measuring the concentration and types of certain pollutants in the surrounding, outdoor air. Some of these pollutants (commonly called ‘Criteria Pollutants’) are considered hazardous to human health and their levels are regulated by government agencies around the world, including the US EPA. Teledyne API provides a complete line of ambient air quality monitoring instruments, including those for both gas and...

    By Teledyne API based in San Diego, CALIFORNIA (USA).

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B...

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Odour Monitoring

    Measurement of odours from pulp & paper, feedlots and natural sources is challenging and requires careful selection of instrumentation. Ecotech offers a complete monitoring solution designed for this application. Odours are one of the most common sources of air pollution complaints and may be due to a wide variety of sources from rotting vegetation, animal feedlots, pulp and paper manufacturing, sewerage treatment facilities etc. The measurement of odours is extremely difficult due to the variety of sources...

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Air sampling & monitoring systems for energy/utilities industry

    Finding efficient ways to generate, deliver and consume energy resources while reducing pollution is an ongoing quest for the Energy & Utility Industries. HI-Q has developed instrumentation geared toward monitoring emissions and the dispersal of pollutants from power plants and industrial facilities. HI-Q base-line & stack sampling equipment has been used in studies to identify and track the spread of pollutants around the globe.

    By HI-Q Environmental Products Company based in San Diego, CALIFORNIA (USA).

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Traffic Emissions Monitoring

    Traffic, especially in urban locations, is one of the greatest contributors to air pollution. Traffic produces a variety of different pollutants that include particulates, NO2, NO, CO, hydrocarbons and in some cases SO2. The monitoring of roadside pollution can be challenging as often it is difficult to find suitable locations for large air quality monitoring systems and many sites that are available can be too far away to be representative of roadside air pollution. Roadside pollution concentrations can change...

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you