air separation plant Applications

4 Results found
Only show results available in Virginia?
OK
  • Keyword: air separation plant ×

Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

e-scrap recycling System

by Jiangxi Mingxin Metallurgy Equipment Co.,Ltd.     based in Shicheng County, CHINA

PCB Boards and E-scrap Recycling Plant 3.Why buy MINGXIN's E waste(PCB) Recycling plant ? Get the metal separated from waste circuit board through crushing and air separation process. No incineration and pollution. compliance with EHS standard, no harmfulness to workers, eco-friendly solution for E waste recycling. The plant has 5 advantages: A. The coarse crush can grind baseplate and separate electronic component.. B. National Environment Protection Standard achieved. No dust leak and no secondary pollution . C. Low energy consumption but high production. D. High metal recovery rate which reaches 97%-99%. Metal content in on-metal powder is less than 1%. E. Patent number: ZL02247015.8

Related Terms for air separation plant

Need help finding the right suppliers?

Let the XPRTs do the work for you