Only show results in Virginia? Ok

air separator Applications

  • Moisture Monitoring for Air Separation Units & Speciality Gases

    A variety of bottled gases are certified for resale as "calibration gases ", specifying the concentration of contaminants in each bottle. Often the water content is specified, and this must be monitored with precision both by the supplier and consumer.

    By Moisture Control & Measurement Ltd based in Wetherby, UNITED KINGDOM.

  • Prescribed Burning

    A general understanding of the separate and combined effects of several weather elements on fire behavior is needed to plan and execute a good prescribed burn. Because weather and fuel factors interact, an experienced prescribed burner can conduct a successful burn even with one or more factors slightly outside the desired range—as long as they are offset by other factors. Accurate fire weather monitoring of fire danger indices via the RAWS network, providing historical data leading up to a prescribed burn is critical in the planning stages. However, having accurate weather conditions in a micro-climate scale in real time during the execution of a prescribed burn is just as critical. The weather variables most applicable to prescription burns are air temperature, relative humidity, wind direction, wind speed and precipitation. A combination of wind speed, relative humidity, temperature, and solar insulation largely determines fuel condition which in turn affects fire behavior.

    By FTS based in Victoria, BRITISH COLUMBIA (CANADA).

  • Premium

    Emission control & air dedusting for calcination processes

    In calcination processes, solid intermediates and products are regularly handled in fine powder form. (ex: kaolin or metakaulin). There is a need to separate these very fine powders from the exhaust streams of calciners, fluid bed dryers or incinerators, often at critical temperature conditions 

    By Advanced Cyclone Systems, S. A. based in Porto, PORTUGAL.

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Air pollution control for the chemical processing industry

    Anguil thermal and catalytic oxidizer systems are used on various applications throughout the chemical processing industry for emission abatement. Our experience includes applications on tank vents, amine tail gases, API separators, acid gases, inert streams and more. Regulatory Compliance Guaranteed, Seamless Process Integration, Efficient Destruction Technologies, Advanced System Controls.

    By Anguil Environmental Systems, Inc. based in Milwaukee, WISCONSIN (USA).

  • Premium

    Air pollution control (APC) equipments for waste incineration

    Waste incineration is a complex area. The mix of waste, moisture content, temperature of the waste, surrounding air and a variety of other factors interact and affect which residues are formed. Combustion entails often a gas consisting of heavy metals, sulfur oxides, chlorides, dioxins, etc. It is extremely important with a proper handling of the gas and the task often requires a mixture of wet and semi-dry treatment. EnviBAT offers equipment that brings particle levels down to extremely low levels, which guarantees a total separation of dioxins and wet purification that separates contaminants found in the gas phase.

    By Envibat AB based in Skellefteå, SWEDEN.

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Odor control for refining/petroleum

    You refine the fuel, we’ll remove the odors. Oil refineries and petrochemical plants may generate large volumes of odor from the processing and refining of different fuels. Sulfides, mercaptans, and hydrocarbon compounds are all closely related to the oil industry. The odors generated from these industrial compounds are of a high nuisance value and generally create concern among local air boards and the public. Ecosorb odor removal products may be used in a variety of areas around the refinery including water treatment facilities, sludge ponds, sulfur recovery units, and API separators. To remove odors during tank cleaning and maintenance operations, portable dispersion systems can be used in the immediate work area to control malodors. Ecosorb products can be directly injected into flues and stacks and may be used as a substitute scrubbing solution in some applications.

    By OMI Industries (OMI) based in Long Grove, ILLINOIS (USA).

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Industrial

    We have a specialist range of skimmers and systems to suit the requirements of the industries, including in-tank skimming. The removal of oil and chemicals from water within the industrial environment is a key requirement – not only due to increased legislation but also because it is considered a dependable and cost effective way to achieve the desired level of water purity. It can also increase the efficiency of existing installations, such as large scale API oil-water or parallel plate separators, without the need for expensive capex expansions or new builds. The DESMI skimmers are typically manufactured from high nickel alloys to resist ‘sour’ applications and can be hydraulic, air or low voltage drive. In applications that require ATEX or equal qualification, we can satisfy this requirement.

    By DESMI A/S based in Noerresundby, DENMARK.

  • Premium

    Gas analysis & monitoring system for gas purity

    The purity of a gas is an indication of the amount of other gases contained in it. A high purity refers to a low amount of other gases. High purity gas are considered to be of better quality and are generally more expensive. The purity of the gas can be expressed as a percentage or as a decimal fraction. Applications for checking the purity of the gases across different industrial sectors by air separation plants, cryogenic facilities, the quality control of industrial gases to the steel mills, etc.

    By ETG Risorse e Tecnologia based in Montiglio, ITALY.

  • SRF

    SRF Manufacture is an alternative fuel produced by shredding and dehydrating solid waste, typically consisting of combustible components of solid waste, including paper, card, wood, textiles and plastic. It can be produced to a range of specifications to meet customer requirements. Solid Recovered Fuel Manufacture The materials used to produce Solid Recovered Fuel pass through a series of shredders, screens, air classifiers/density separators and magnets. Inert materials, recyclable plastics and metals are extracted from the shredded material, leaving a mix of mainly non-recyclable paper, card, wood, textiles and plastic. Although a small proportion of these materials can be recycled the quality of these materials is compromised once they enter the residual waste stream and recovering energy from these materials is currently the best environmental option. For More information: https://the-mkgroup.com/portfolio/srf-manufacture/

    By MK Group based in Galbally, IRELAND.

  • e-scrap recycling System

    PCB Boards and E-scrap Recycling Plant 3.Why buy MINGXIN's E waste(PCB) Recycling plant ? Get the metal separated from waste circuit board through crushing and air separation process. No incineration and pollution. compliance with EHS standard, no harmfulness to workers, eco-friendly solution for E waste recycling. The plant has 5 advantages: A. The coarse crush can grind baseplate and separate electronic component.. B. National Environment Protection Standard achieved. No dust leak and no secondary pollution . C. Low energy consumption but high production. D. High metal recovery rate which reaches 97%-99%. Metal content in on-metal powder is less than 1%. E. Patent number: ZL02247015.8

    By Jiangxi Mingxin Metallurgy Equipment Co.,Ltd. based in Shicheng County, CHINA.