ambient air analyzer Applications

21 Results found
Only show results available in Virginia?
OK
  • Keyword: ambient air analyzer ×

Perimeter Ambient Air Monitoring

by Cerex Monitoring Solutions, LLC.     based in Atlanta, GEORGIA (US) (USA)

Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring. Cerex multi-gas analyzers offer significant advantages over single gas analyzer arrays, electro-chemical sensor arrays and time integrated air sampling hardware

Measurement of diacetyl in ambient air to monitor workplace exposure limits.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Ambient air monitoring by FID detection – airmoVOC BTEX

by Chromatotec Group     based in Val de Virvée, FRANCE

Urban pollution is a problem that concerns more and more people in charge of public health. In large cities, car emissions are an important source of atmospheric pollution. This problem is growing as the traffic keeps on increasing. BTEX compounds are present in car emissions. It is therefore important to be able to analyze them with short analysis cycle duration and on a continuous and automatic way.

Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Open Path Ambient Air Quality Monitoring

by Cerex Monitoring Solutions, LLC.     based in Atlanta, GEORGIA (US) (USA)

Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring.

Ambient Monitor Gas Calibration with Ozone Generators

by Environics, Inc.     based in Tolland, CONNECTICUT (USA)

Environics® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Measurement of methane and non-methane hydrocarbons for environmental air quality.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane hydrocarbons that are of primary concern.

Data Acquisition and Control

by CEMS Experts - a division of GK Associates, Inc.     based in Simi Valley, CALIFORNIA (USA)

Many companies worry over the quality of emissions data reported to the EPA. CEMS Experts is a skilled and experienced company with over 20 years of proven and dependable service to provide you with a reliable solution to your Analyzer Management and Data Acquisition Software needs. We supply customized DAS solutions for all federal (EPA), state and local CEMS regulations, plus off-the-shelf products for process monitoring, ambient air testing, or any other application requiring fast, reliable data capture and reporting.

Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

by Environnement S.A     based in Poissy, FRANCE

With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

Measurement of methyl ethyl ketone, chloroform & carbon tetrachloride in air for remediation & super fund sites

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 Analyzer provides direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride in ambient air. This instrument is utilized for remediation and Super Fund sites and to monitor workplace exposure limits.

Air sampling & monitoring systems for biomedical, chemical & pharmaceutical industry

by HI-Q Environmental Products Company     based in San Diego, CALIFORNIA (USA)

HI-Q Environmental Product Company provides air sampling instrumentation & systems for several niche applications in a number of disciplines in the broad area of `Life Sciences`. In the Biomedical, Chemical, & Pharmaceutical industries, HI-Q has marketed instrumentation for certain applications for many years. Our ambient, in-door breathing level air samplers, commonly known in the industry as `Goose-Neck` or `Giraffe` air samplers have been instrumental in analyzing workplace exposure. HI-Q has also developed accurate pre & post heap filtration stack sampling systems to aid laboratories in inventory control & atmospheric exposure monitoring for chemicals such as Radio Iodine.

Gas monitoring instruments and systems for flavoring agents

by Gasmet Technologies Oy     based in Helsinki, FINLAND

Manufacturing of powdered and liquid flavorings and fragrances involves production phases where flavoring chemicals may be released into the ambient air breathed by workers. Exposure control by gas analyzers in the production rooms and laboratories is necessary to ensure that the Time-Weighted Average (TWA) concentrations do not exceed the maximum Permissible Emission Limit (PEL) values.

Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

Gas monitoring instruments and systems for semiconductor manufacturing

by Gasmet Technologies Oy     based in Helsinki, FINLAND

In the semiconductor manufacturing industry, various perfluorinated compounds (PFCs) are used. The emissions of the PFC compounds into the ambient air are reduced by scrubbing of the exhaust gases from the process. In this process, the Gasmet™ FTIR Gas Analyzers can be used to measure the emissions into the atmosphere and also monitor the efficiency of the scrubbers. Typically monitored PFCs in the exhaust gas include carbon tetrafluoride CF4, trifluoromethane CHF3, and hexafluoroethane C2F6.

Gas monitoring instruments and systems for phosgene monitoring

by Gasmet Technologies Oy     based in Helsinki, FINLAND

Phosgene COCl2 is a colorless gas. While it has been used as a Chemical Weapon Agent (CWA) in the past, currently this poisonous gas is also an important reagent in synthesis in the pharmaceutical and chemical industries. The plants using phosgene are typically equipped with gas sensors to detect leaks in the indoor ambient air. The critical situations arise when equipment in contact with the gas at the manufacturing facilities are serviced and maintained. As phosgene is very poisonous, even small gas pockets in serviced equipment may be dangerous to maintenance personnel. Gasmet™ FTIR Gas Analyzers are ideal tools to monitor point sources of phosgene. The measurement technology has high specificity, may be operated continuously, and has a fast response time.

Need help finding the right suppliers?

Let the XPRTs do the work for you