Only show results available in Virginia? Ok

ambient air measurement Applications

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Diacetyl and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The Diacetyl is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Measurement solution for accurate continuous formaldehyde measurement formaldehyde in emissions and ambient air applications

    Formaldehyde (HCHO) is the simplest aldehyde species and is present, or generated by, many sources (both natural and industrial). It is classed as a substance that is toxic and harmful to human health.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

    The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Ambient Stations for Ambient Air Quality Monitoring

    Ambient air monitoring involves the measurement of `representative` air in urban, industrial and rural areas. These measurements are used to determine the human exposure to pollutants and can be combined with trace/background monitoring.

    By Opsis AB based in Furulund, SWEDEN.

  • Measurement solution for ambient air workplace monitoring

    Protea can supply fixed workplace monitoring systems that can measure single or multi-points about the workplace. Specifically designed analytical systems can ensure detection limits down to ppb levels can be achieved for multiple gases with a single instrument. Controlling software can run automatically, providing instantaneous or time-weighted average readings.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Ambient air quality monitoring at airports

    To measure the ambient air quality at airports is a challenge. The monitoring site needs to be representative for background levels and not dependant on changes in local traffic. A large number of gaseous components need to be measured with high accuracy and high availability. The OPSIS DOAS system provides the user with a fast system that gives high availability at low cost. The impact of aircraft take-offs and landings can easily be followed on-line. The OPSIS system can also monitor fugitive emissions from other sources at the airport.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    BTEX in Ambient Air Application using a High-Sensitivity PID

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Ambient Continuous Metals Monitoring/ Fence Line Monitoring/ Source Identification

    The Xact® 625i combined with ADAPT software creates the industry's most powerful tool for high time resolution detection of airborne metals. The Xact® 625i measures trace metals at very low detection limits at time resolutions down to 15 minutes. The ADAPT package captures corresponding wind speed and wind direction data, then seamlessly integrates the measurements into wind regression analyses available at the touch of a button. This creates the most single most powerful fence line/ source identification instrument in the industry.

    By Cooper Environmental Services based in Beaverton, OREGON (USA).

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane hydrocarbons that are of primary concern.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Ambient air quality monitoring solutions for street-level monitoring

    To measure the air quality in a city is a challenge. A large number of gaseous components need to be measured with high accuracy. The monitoring site needs to be representative for the city and the system has to be easy to maintain and calibrate. The OPSIS open-path monitoring systems provide a flexible solution, giving the average concentration for an area. A single OPSIS system can measure all relevant gaseous components set by the authorities, such as NO, NO2, SO2, O3, BTX, NH3.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Ambient air quality monitoring solutions for remote sensing of ship emissions

    New regulation forces ships to lower the emissions of SO2. Ships travelling in SECA areas has to either run on low sulphur fuel, or install SO2 scrubbers. To measure the SO2 emissions from a ship is not an easy task. OPSIS provides the Port Authorities with a unique measurement principle where the emissions from the ship is measured remotely. Light is passing the emissions and by analyzing the light, concentrations of SO2 can be measured.

    By Opsis AB based in Furulund, SWEDEN.

  • NOx Analyzers for environmental, ambient air and research industry

    Focuses on low NOx and NOx-related concentrations up to 100 ppm where high resolution is required. Parameters included are NO, NO2, NOx and NOy. Target applications are ambient air monitoring, indoor measurement, clean room measurement and atmospheric research.

    By Eco Physics Inc. based in Ann Arbor, MICHIGAN (USA).

  • Premium

    Ambient air quality monitoring solutions for fence-line monitoring

    The OPSIS open-path monitoring system is an excellent tool for monitoring the air quality, fugitive emissions and gas leaks at industrial sites. By arranging monitoring paths strategically at locations outside the borderline of an industrial area, fugitive emissions and gas leaks will effectively be detected. By combining the measured gas data with meteorological parameters information such as where the pollution sources are located and the strength of the emissions can be calculated, using the EnviMan software.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methyl ethyl ketone, chloroform & carbon tetrachloride in air for remediation & super fund sites

    The Series 8900 Analyzer provides direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride in ambient air. This instrument is utilized for remediation and Super Fund sites and to monitor workplace exposure limits.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Urban air quality monitoring

    To measure air quality in the ambient air is a challenge. The monitoring site needs to be representative and not dependant on changes in local traffic. A large number of gaseous components need to be measured with high accuracy and high availability.

    By Opsis AB based in Furulund, SWEDEN.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you