Only show results in Virginia? Ok

ambient air monitoring instrumentation Applications

  • Measurement solution for ambient air workplace monitoring

    Protea can supply fixed workplace monitoring systems that can measure single or multi-points about the workplace. Specifically designed analytical systems can ensure detection limits down to ppb levels can be achieved for multiple gases with a single instrument. Controlling software can run automatically, providing instantaneous or time-weighted average readings.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Ambient Monitor Gas Calibration with Ozone Generators

    Environics® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Premium

    Ambient Continuous Metals Monitoring/ Fence Line Monitoring/ Source Identification

    The Xact® 625i combined with ADAPT software creates the industry's most powerful tool for high time resolution detection of airborne metals. The Xact® 625i measures trace metals at very low detection limits at time resolutions down to 15 minutes. The ADAPT package captures corresponding wind speed and wind direction data, then seamlessly integrates the measurements into wind regression analyses available at the touch of a button. This creates the most single most powerful fence line/ source identification...

    By Cooper Environmental Services based in Beaverton, OREGON (USA).

  • Premium

    BTEX in Ambient Air Application using a High-Sensitivity PID

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

    The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Dust monitoring and Sand Storm Monitoring

    The frequency and intensity of dust and sand storms in many parts of the world are steadily increasing due to droughts and climate change. The severity of such storms is anticipated to increase over the coming years. These dust storms may last hours or days and cause huge damage and imposed a heavy toll on society with its physical effects, such as visibility reduction, heavy winds, red sky, hailstone and severe lightning. Such Dust storms, have a negative impact on human health, and industrial products and...

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas monitoring instruments and systems for print factories

    Typical modern printing processes utilize solvent-based dyes. The evaporation of the dye solvents into the ambient air during the printing process may expose the workers to various chemicals. Depending on the type of solvents in case, the solvents have different long term exposure limits, which should be obeyed. Component specific measurements are necessary to protect the workers from exposure while avoiding unnecessary interruptions to the printing process from false alarms.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas monitoring instruments and systems for phosgene monitoring

    Phosgene COCl2 is a colorless gas. While it has been used as a Chemical Weapon Agent (CWA) in the past, currently this poisonous gas is also an important reagent in synthesis in the pharmaceutical and chemical industries. The plants using phosgene are typically equipped with gas sensors to detect leaks in the indoor ambient air. The critical situations arise when equipment in contact with the gas at the manufacturing facilities are serviced and maintained. As phosgene is very poisonous, even small gas pockets...

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas monitoring instruments and systems for semiconductor manufacturing

    In the semiconductor manufacturing industry, various perfluorinated compounds (PFCs) are used. The emissions of the PFC compounds into the ambient air are reduced by scrubbing of the exhaust gases from the process. In this process, the Gasmet™ FTIR Gas Analyzers can be used to measure the emissions into the atmosphere and also monitor the efficiency of the scrubbers. Typically monitored PFCs in the exhaust gas include carbon tetrafluoride CF4, trifluoromethane CHF3, and hexafluoroethane C2F6.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas monitoring instruments and systems for flavoring agents

    Manufacturing of powdered and liquid flavorings and fragrances involves production phases where flavoring chemicals may be released into the ambient air breathed by workers. Exposure control by gas analyzers in the production rooms and laboratories is necessary to ensure that the Time-Weighted Average (TWA) concentrations do not exceed the maximum Permissible Emission Limit (PEL) values.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to...

    By ENVEA based in Poissy, FRANCE.

  • Premium

    Low level measurement of aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring.

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Air sampling & monitoring systems for biomedical, chemical & pharmaceutical industry

    HI-Q Environmental Product Company provides air sampling instrumentation & systems for several niche applications in a number of disciplines in the broad area of `Life Sciences`. In the Biomedical, Chemical, & Pharmaceutical industries, HI-Q has marketed instrumentation for certain applications for many years. Our ambient, in-door breathing level air samplers, commonly known in the industry as `Goose-Neck` or `Giraffe` air samplers have been instrumental in analyzing workplace exposure. HI-Q has also...

    By HI-Q Environmental Products Company based in San Diego, CALIFORNIA (USA).

  • Premium

    Measurement of methane and non-methane hydrocarbons for environmental air quality.

    The Model 8900 Methane/Non-Methane Analyzer provides direct measurement of Methane and Non-Methane Hydrocarbons. This instrument is utilized in ambient air monitoring networks around metropolitan areas, fence-line monitoring at industrial plants and hazardous waste sites, and in the production of high purity industrial gases. Methane is a naturally occurring gas generated from the decomposition of biological materials and industrial activity. Since Methane is not considered a pollutant it is the Non-Methane...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you