Only show results available in Virginia? Ok

ambient air test Applications

  • Ambient Air Passive Sampling

    By Ogawa & Company, USA, Inc. based in Pompano Beach, FLORIDA (USA).

  • Premium

    Perimeter Ambient Air Monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring. Cerex multi-gas analyzers offer significant advantages over single gas analyzer arrays, electro-chemical sensor arrays and time integrated air sampling hardware

    By Cerex Monitoring Solutions, LLC. based in Atlanta, GEORGIA (US) (USA).

  • Premium

    Ambient Stations for Ambient Air Quality Monitoring

    Ambient air monitoring involves the measurement of `representative` air in urban, industrial and rural areas. These measurements are used to determine the human exposure to pollutants and can be combined with trace/background monitoring.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Measurement solution for accurate continuous formaldehyde measurement formaldehyde in emissions and ambient air applications

    Formaldehyde (HCHO) is the simplest aldehyde species and is present, or generated by, many sources (both natural and industrial). It is classed as a substance that is toxic and harmful to human health.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement solution for ambient air workplace monitoring

    Protea can supply fixed workplace monitoring systems that can measure single or multi-points about the workplace. Specifically designed analytical systems can ensure detection limits down to ppb levels can be achieved for multiple gases with a single instrument. Controlling software can run automatically, providing instantaneous or time-weighted average readings.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Open Path Ambient Air Quality Monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring.

    By Cerex Monitoring Solutions, LLC. based in Atlanta, GEORGIA (US) (USA).

  • Premium

    Ambient air monitoring by FID detection – airmoVOC BTEX

    Urban pollution is a problem that concerns more and more people in charge of public health. In large cities, car emissions are an important source of atmospheric pollution. This problem is growing as the traffic keeps on increasing. BTEX compounds are present in car emissions. It is therefore important to be able to analyze them with short analysis cycle duration and on a continuous and automatic way.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Ambient air and emissions monitoring of Polycyclic Aromatic Hydrocarbons – airmoC10-C20+

    Polycyclic Aromatic Hydrocarbons (PAHs) are a group of over 100 different chemicals that are known to be formed typically during incomplete combustion of organic matter at high temperature. Their major sources in the atmosphere include industrial processes, vehicle exhausts, waste incinerations, and domestic heating emissions. Due to their carcinogenic/mutagenic effects, 16 PAHs are currently listed as priority air pollutants.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Measurement of methyl bromide in ambient air for monitoring workplace exposure limits in fumigation facilities

    The Series 8900 Methyl Bromide Monitoring System provides an automated, direct measurement of Methyl Bromide in ambient air. This instrument can meet and exceed the requirements for ambient methyl bromide monitoring. It is utilized in fumigation facilities and industrial plants to detect potential worker exposure to methyl bromide, resulting from mechanical failure, human error or product off gassing. Multipoint sampling options allow the analyzer to monitor multiple sample locations for greater coverage.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Ambient Continuous Metals Monitoring/ Fence Line Monitoring/ Source Identification

    The Xact® 625i combined with ADAPT software creates the industry's most powerful tool for high time resolution detection of airborne metals. The Xact® 625i measures trace metals at very low detection limits at time resolutions down to 15 minutes. The ADAPT package captures corresponding wind speed and wind direction data, then seamlessly integrates the measurements into wind regression analyses available at the touch of a button. This creates the most single most powerful fence line/ source identification instrument in the industry.

    By Cooper Environmental based in Beaverton, OREGON (USA).

  • Ambient Monitor Gas Calibration with Ozone Generators

    Environics® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Premium

    Urban air quality monitoring

    To measure air quality in the ambient air is a challenge. The monitoring site needs to be representative and not dependant on changes in local traffic. A large number of gaseous components need to be measured with high accuracy and high availability.

    By Opsis AB based in Furulund, SWEDEN.

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

  • Air monitoring for laboratories

    Many of the air quality analyses can be performed with standard laboratory consumables, such as traditional filter papers. However, some analyses require materials with specific features, for example filters with low metal levels.

    Common air monitoring applications include:

    • Air quality testing of ambient environment and emissions. Includes particulate monitoring methods such as PM2.5 and PM10, and chemical analysis such as heavy metals determination.
    • Asbestos sampling and analysis

    By GE Healthcare UK Limited based in Little Chalfont, UNITED KINGDOM.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Dust monitoring and Sand Storm Monitoring

    The frequency and intensity of dust and sand storms in many parts of the world are steadily increasing due to droughts and climate change. The severity of such storms is anticipated to increase over the coming years. These dust storms may last hours or days and cause huge damage and imposed a heavy toll on society with its physical effects, such as visibility reduction, heavy winds, red sky, hailstone and severe lightning. Such Dust storms, have a negative impact on human health, and industrial products and activities. They reduce visibility, layer on skin and cloths, infiltrate buildings and find their way into food and drinking water leaving a permanent sandy feeling in your mouth. Traditional dust monitoring instruments whether they be purely filter based gravimetric samplers or continuous monitors utilising Tapered Element Oscillating Microbalance (TEOM) or Beta Attenuation (BAM) simply are unable to cope with the high dust loads created by these storms. The filters on these instruments are quickly clogged and no further measurements are possible until a service technician visits to replace filters and filter tapes. In dust storm events this is impossible. Therefore, over the past few years a need for alternate technology which are non filter based, can cope with extremely high dust loads, require minimal maintenance and can operate off solar power has been employed in regions such as the Gobi Desert of China for the continuous monitoring of dust storm events. These instruments have demonstrated that an instrument can measure dust storm events with maintenance performed only once every 12 months. That it is possible to communicate remotely and that these systems can not only provide an early warning for dust events but have the accuracy and sensitivity to be an extremely useful tool in gauging hourly changes of visibility. Infact such instruments have been utilised by a number of EPAs around the world, including all Australian EPAs for the purpose of measuring ambient visibility as well as providing an accurate indication of rising dust events.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Data Acquisition and Control

    Many companies worry over the quality of emissions data reported to the EPA. CEMS Experts is a skilled and experienced company with over 20 years of proven and dependable service to provide you with a reliable solution to your Analyzer Management and Data Acquisition Software needs. We supply customized DAS solutions for all federal (EPA), state and local CEMS regulations, plus off-the-shelf products for process monitoring, ambient air testing, or any other application requiring fast, reliable data capture and reporting.

    By CEMS Experts - a division of GK Associates, Inc. based in Simi Valley, CALIFORNIA (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you