ammonia measurement Applications

  • radiello™ Passive Sampler as a Tool for the Measurement of Atmospheric Ammonia Concentrations and Dry Deposition

    The radiello ammonia sampler impregnated with phosphoric acid represents a low-cost, reliable and simple tool for assessing the atmospheric deposition of ammonia at parts per billion (ppb) concentration levels.

    By MilliporeSigma based in Bellefonte, PENNSYLVANIA (USA).

  • Integrated real-time gas analysis solution for moisture in ammonia industry

    The highest purity of ammonia is a requisite chemical gas for the production of flat panel displays and for LEDs; the purity issue is one of achieving moisture levels at the ppb level, as in the case of epitaxial reactor applications. However, the problem requiring a solution derives in part from the fact that the FTIR spectra for moisture and ammonia overlap to the degree that the moisture peaks are masked by the ammonia peaks at high concentrations. As a result the moisture peaks cannot be used for quantitative concentration measurements.

    By CIC Photonics, Inc. based in Albuquerque, NEW MEXICO (USA).

  • Premium

    Gas monitoring instruments and systems for process NOx measurement

    Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Measurement solution for high NH3 monitoring from wastewater

    Protea was asked to supply a high level ammonia (NH3) measurement system for a waste water treatment plant. The reflux drums at the inlet to two ammonia stripping towers needed to be measured continuously. Protea designed a solution based around our Solus TDLAS analyser platform and a high level dilution system. The Solus analyser was configured for NH3 measurements in the range 0-500ppm. A dilution system incorporating special dilution probe and 19` control panel was installed before the analyser. This gave a dilution level of 600:1, enabling the NH3 analyser to measure in the range 0-30% Volume.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Environmental monitoring solution for fertilizer plants

    Measurement of particulates, SO2, NOX, ammonia, fluorides and greenhouse gas emissions from the fertilizer industry requires careful selection of instruments. Ecotech offers a complete monitoring solution tailored to this industry.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Process monitoring solutions for NH3 truck engine monitoring

    A new EC regulation states that  diesel engines need to have active cleaning with urea injection in order to reduce NOx emissions. In order to control the urea dosage, a reliable measurement system is required. OPSIS LD500 laser diode gas analyser for monitoring ammonia (NH3), has been tested and approved by German TÜV, in accordance with the EURO VI standard.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Determination of cations in beverages

    The method enables fast determination of inorganic cations (sodium, potassium, calcium, and magnesium) in the samples of juices, beer, wines, brandies, brandy alcohols, and raw materials by capillary electrophoresis. 

    The method for evaluation of cations concentration is based on differential migration and separation of cations in electric field due to the difference in their electrophoretic mobility. Identification and quantitative determination of the analyzed cations is performed by indirect detection measuring UV absorption at 254 nm (for “CAPEL® -103RT/104T” systems) or 267 nm (for “CAPEL® -105/105M” systems) wavelength. 

    The determination is not hindered by the presence of anions of ammonia, lithium, strontuim, barium, manganese, ferrum (II) in the quantities that are typical for the analyzed drinks. 

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Premium

    Determination of organic acids in beverages

    The method allows determination of organic acids, in soft drinks (juices, fizz drinks) and alcoholic drinks (wines, beer). 

    The capillary electrophoresis method for evaluation of cations concentration is based on differential migration and separation of cations in electric field due to the difference in their electrophoretic mobility. Identification and quantitative determination of the analyzed cations is performed by indirect detection measuring UV absorption at 254 nm (for “CAPEL® -103RT/104T” systems) or 267 nm (for “CAPEL® -105/105M” systems) wavelength.

    The determination is not hindered by the presence of anions of ammonia, lithium, strontuim, barium, manganese, ferrum (II) in the quantities that are typical for the analyzed drinks. 

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Odour Monitoring

    Measurement of odours from pulp & paper, feedlots and natural sources is challenging and requires careful selection of instrumentation. Ecotech offers a complete monitoring solution designed for this application. Odours are one of the most common sources of air pollution complaints and may be due to a wide variety of sources from rotting vegetation, animal feedlots, pulp and paper manufacturing, sewerage treatment facilities etc. The measurement of odours is extremely difficult due to the variety of sources of odour and the often very low ppb concentrations that produce odour. However, some industries and applications have a known source of odour resulting from compounds such as mercaptans, hydrogen sulphide, ammonia, typically from industries such as pulp and paper manufacturing, fertiliser production or natural sources such as rotting vegetation. Ecotech is able to offer extremely sensitive instrumentation and systems that enables the low ppb monitoring of these species down to 1 ppb, fully integrated with our data evaluation and reporting software.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you