Only show results available in Virginia? Ok

analytical instrument industry Applications

  • Reproducible Measurement for Robust Quality Control with the J200 LIBS Instrument

    In this tech note, we demonstrate how Applied Spectra’s J200 LIBS Instrument is ideal for performing many industrial measurement applications, including quality control (QC) during manufacturing processes. Request this application note at http://appliedspectra.com/applications/application-notes.html

    By Applied Spectra, Inc. based in Fremont, CALIFORNIA (USA).

  • Premium

    Flow Measurement instrumentation for digital flow meter air measurement solutions

    From heavy industrial to research and analytical applications, Sierra has a wide range of digital air flow meters and controllers with digital output protocols. Sierra offers digital gas flow meters and mass flow meters across two core technologies: Capillary Thermal, and Immersible Thermal.

    By Sierra Instruments, Inc. based in Monterey, CALIFORNIA (USA).

  • Premium

    Measurement solution for fire testing for the railway industry

    A lot of research is carried out in laboratory and on real fires as to the gaseous substances produced in fire effluent. Measurement principles using analytical instrumentation are becoming more widely used in fire testing, due to the quick, real-time nature of the measurements. ISO 19702 is an international standard developed for the use of FTIR analysers in the analysis of gas from fire effluents. Further to this, local test standards such as DIN 5510, applicable to the railway industry, can provide further requirements for gases to be measured.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Measurement of sulphur in oil and fuels for oil & gas industry

    There is a continuing and increasing demand for a rapid, simple and cost-effective measurement of sulfur in a wide range of petroleum products including automotive, marine and aviation fuels. Benchtop EDXRF instruments such as the world renown Lab-X3500 and associated X-Supreme8000, can be found in many refinery laboratories/testing houses, with the instrument often operated by production staff on a 24/7 basis, giving accurate results conforming to globally accepted test methods, e.g. ASTM D4294, ISO20847, and the new ISO13032,etc. Both instruments used the analytical technique of Energy-Dispersive X-ray fluorescence (EDXRF) which is well regarded for its excellent performance, versatility, ease of use, speed, and cost-effectiveness.

    By Oxford Instruments plc based in Abingdon, UNITED KINGDOM.

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of naphthalene in ambient air to monitor workplace exposure limits & at remediation & Superfund sites

    The Series 8900 Naphthalene Analyzer provides direct measurement of Naphthalene in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits and at remediation and Superfund sites. The Series 8900 Naphthalene Analyzer employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Naphthalene and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Naphthalene is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Formaldehyde and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Formaldehyde is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Acrylonitrile and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. Acrylonitrile is separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Application package glass

    This application package is a 'ready to go' calibration kit for xrf instruments. In the glass industry, raw materials have to be analysed together with the quality control samples from production. FLUXANA has created two basic programs Raw Materials (CS-0022) and Glass (CS-0016) for these two purposes, which can be individually adapted by the customer. FLUXANA application packages include always the sample preparation method. All packages are running in our application laboratory. You are always free to send your samples for testing free of charge. If you combine our application packages with our sample preparation machines FLUXANA garanties the analytical performance of the package like a contract.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you