Only show results available in Virginia? Ok

arsenic analysis Applications

  • XRF analysis for environmental applications

    Niton analysers are versatile environmental testing instruments that provide valuable assistance in portable soil testing applications such as brownfield site investigation. With the ability to analyse a wide range of materials, our instruments provide lab-quality soil/sediment chemistry in seconds. Lead, arsenic, cadmium, chromium, and other toxic metals contaminate sites of former industrial and agricultural activity around the world. Whatever the reasons for these occurrences, these pollutants cannot be ignored – particularly as environmental consciousness and regulatory initiatives grow.

    By Niton UK Limited based in Woodmancott, Winchester, UNITED KINGDOM.

  • Premium

    Determination of heavy metals in food

    This analytical procedure is intended for measuring the content of the elements (cadmium, lead, arsenic, tin, chromium and mercury) in the samples of food products by atomic absorption spectrometry with electrothermal atomization using an “MGA-915M” Graphite Furnace AA Spectrometer.

    The method is based on measuring resonance radiation absorption that occurs when the radiation passes through a layer of atomic vapor in the electrically heated graphite furnace of the “MGA-915M” AA spectrometer. The concentration of the elements is determined from the integrated analytical signal and is calculated using a preset calibration graph. The samples of food products are digested prior to analysis in accordance with standard methods. 

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Saran Bag application

    Title : Preliminary Sampling Methodology and Analytical Procedures for Ambient Sulfur Hexafluoride, Corporate Author : ARMY MEDICAL ENVIRONMENTAL ENGINEERING RESEARCH UNIT EDGEWOOD ARSENAL MD Personal Author(s) : Luckan,Susan K. ; Cooper,William J. Report Date : JAN 1973 Pagination or Media Count : 23 Abstract : A preliminary evaluation of techniques of sampling and gas chromatographic analysis for low levels of sulfur hexafluoride was conducted to determine the most feasible method for available equipment. Using a Tracor MT-150 gas chromatograph equipped with Nickel 63 electron capture detector and polarized dc voltable, it was possible to detect sulfur hexafluoride at a concentration of 0.06 ppb with a 5A molecular sieve column and nitrogen carrier gas, without preconcentration of the sample. Also, a comparison of glass and Saran sampling materials proved that no detectable loss of the tracer gas resulted with the Saran bags (between 6 ppm and 0.06 ppb SF6

    By Analytical Specialties, Inc. based in Elburn, ILLINOIS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you