Only show results available in Virginia? Ok

benzene sample Applications

  • EPA 325 Benzene Fenceline monitoring

    EPA Method 325 Fenceline Monitoring Golden provides analytical products and services for compliance with fenceline monitoring requirements In addition to our analytical services to support source testing and other environmental projects, Golden Specialty, Inc. provides high quality analytical and consulting services and products to support our clients needs for compliance with the new EPA Method 325 fenceline monitoring requirements. We have been supporting clients with their EPA 325 needs since 2015 and are experienced and qualified to help you! Frequently Asked Questions Fenceline Monitoring Products and Services Golden provides a multitude of products and services to assist you with your compliance with EPA's refinery fenceline monitoring requirements. From mapping and installing monitoring stations, to analyzing sampling tubes, Golden is qualified to assist you every step of the way. You can also access it from our website on the Fenceline Monitoring page: http://goldenspecialty.com/Benzene_Monitoring.php and click on the “Get e-Mail Updates” button

    By Golden Specialty, Inc. based in Friendswood, TEXAS (USA).

  • Premium

    Low concentrations monitoring of benzene and aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    With over 15 years of experience in the measurement of volatile organic compounds (VOC), Environment SA announces the VOC72M, a new generation analyzer for the measurement of BTEX compounds by gas chromatography with photo-ionization detector (PID). The VOC72M can handle up to 40 compounds and eight configurations for analysis. This compact and fully automated analyzer with wide voltage range specifications (90-240V) provides equivalent performance to the laboratory chromatographs and is particularly suited to fixe or mobile ambient air quality monitoring laboratories. The VOC72M is fitted with a PID detector new generation, much more sensitive, more stable and whose lamp does not need to be cleaned; the analyzer integrates flow control fittings a 3 levels security system built on and uses only one gas (nitrogen). This robust and low maintenance instrument performs all the functions (sampling, analysis and data management) in a simple and completely autonomous mode. It is a particular

    By Environnement S.A based in Poissy, FRANCE.

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Air and particule sampling for the oil and gas industries

    Ormantine offers a wide range of products and services to meet the array of different needs that arise in the oil and gas industries. Volatile Organic Compounds (VOCs), benzene, and other compounds are released during drilling, hydraulic fracturing (fracking) and other extraction procedures. Monitor NOx emissions from heavy duty equipment, particulate matter, and ground level ozone, the formation of which is contributed to by VOCs from processing, transportation, and storage of oil and gas.

    By Ormantine USA Ltd., Inc. based in Palm Bay, FLORIDA (USA).

  • Premium

    Measuring aromatic hydrocarbons (BTEX) for pollution control and environmental monitoring

    The Series 8900 BTEX Analyzer provides direct measurement of Benzene, Toluene, Ethylbenzene, and Xylenes in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites. The Series 8900 BTEX Analyzer employs a photoionization detector (PID) as the sensing element. This detector is specific to volatile organic compounds. The Benzene, Toluene, Ethylbenzene, and Xylene`s in the gas sample are physically separated using proprietary GC columns.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you