Only show results available in Virginia? Ok

bod measurement Applications

  • Water quality monitoring for brewery industry

    Monitoring process streams and waste streams continuously in a brew house can provide many benefits to operations. Monitoring product in process for color or concentration provides consistency and quality measures. Product loss can be quantified by monitoring waste streams. Processes can be improved to increase efficiency and minimize effluent waste. Effluent waste streams can also be monitored for organic loading with BOD and COD correlations to ensure compliance for discharge.

    By Real Tech Inc. based in Whitby, ONTARIO (CANADA).

  • Chemical Oxygen Demand (COD) Analyzer for Cleaner and Safer Drinking Water

    MANTECH’s chemical oxygen demand (COD) analyzer is breaking new ground in the science of monitoring source and treated drinking water. In addition to providing 15-minute COD results and biochemical oxygen demand (BOD) estimates, MANTECH’s PeCOD® Analyzer measures natural organic matter (NOM) in raw and treated drinking water. The NOM Analyzer™  — which is the drinking-water application of MANTECH’s novel PeCOD® COD-testing system — does what no other technology has done before. It quickly and safely measures oxygen demand and the associated oxidative changes in organic matter in raw and treated drinking water, at low concentrations and without the use of hazardous chemicals.

    By MANTECH Inc. based in Guelph, ONTARIO (CANADA).

  • Wastewater solutions for municipal sewer control

    Problem: A significant portion of the operational costs of a conventional municipal wastewater treatment plant employing an aerobic biological treatment unit comes from electricity costs associated with aeration. In many cases, the aeration rates are kept at the maximum level to ensure that the plant’s effluent is in compliance with the regulations. The critical parameter for regulatory purposes and treatment efficiency, BOD, takes 5 days to measure through standard methods providing almost no value to the plant operators in terms of adjusting aeration rates and chemical dosing.

    By Real Tech Inc. based in Whitby, ONTARIO (CANADA).

  • Wastewater solutions for the industrial effluent pollution management

    Problem: Industrial manufacturers face stringent regulations for discharging wastewater to the environment and municipal sewer systems. Biochemical Oxygen Demand (BOD) is a primary concern for many discharge limits, as wastewaters high in BOD can have adverse impacts on the aquatic environments by leading to oxygen depletion. In some cases, as a means to supplement BOD, it is also desirable to monitor chemical oxygen demand (COD) of industrial effluents. Both of these tests, are time and labour intensive reducing the frequency at which they can be measured for a given effluent.

    By Real Tech Inc. based in Whitby, ONTARIO (CANADA).

  • Chemical Oxygen Demand (COD) Analyzer for Food & Beverage Industry

    Real Time Chemical Oxygen Demand Improves Wastewater Management. MANTECH’s PeCOD Analyzer water quality analysis technology provides food and beverage processors with accurate, real time data that enables them to make timely decisions and effectively manage their water and wastewater. The PeCOD Analyzer is a fast, green, accurate alternative to traditional chemical oxygen demand (COD) and biological oxygen demand (BOD) testing for measuring organics in wastewater. Rapid, reliable and economical testing helps companies remain in compliance with their permits and respond quickly when they are not.

    By MANTECH Inc. based in Guelph, ONTARIO (CANADA).

  • Real-time In-situ Effluent Monitoring

    The UviLux BOD Indicator enables in-situ, real-time, reporting of BOD within both natural water systems and water processing plants. The monitor detects fluorescent proteins that are inherent within sewage and slurry and provides an output in BOD equivalent units. The principle behind the measurement is the excitation of Tryptophan-like fluorescence within UV wavelength band, which has been shown to correlate with both BOD and bacterial contamination. With complete flexibility of deployment methodology, the UviLux BOD Indicator can be applied to both water supply and water recovery processing plants. For water supply processing, the UviLux BOD Indicator can be applied at the front end to the water intake to provide alarm of any contaminated water entering the plant. Applications within Waste Water Treatment Works can include monitoring of effluent levels at the final outflow point (into rivers and coastal areas) as well as the primary, secondary & tertiary stages, the data potentially feeding into energy saving systems to optimise process performances. The CTG UviLux BOD Indicator in-situ fluorometer can also be used within pipe and channel networks to test for incidences of black water and grey water cross-over.

    By Chelsea Technologies Group based in West Molesey, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you