    Sound Instrumentation for Calibration

    Unfortunately, the word calibration has ended up having two meanings; viz. to describe the use of a sound calibrator in connection with a measurement and to describe periodic verification which is carried out in a Calibration Laboratory.

    By Norsonic AS based in Lierskogen, NORWAY.

  • calibration gas

    calibration gas , British specialty gases company, with a local North Africa presence. We can supply you with high quality gas mixtures for a wide range of applications including Environmental Monitoring, Gas Detection, Mud Logging, Laser Cutting, and Laboratory Analysis. Our gas mixtures are used in the Oil, Gas and Petrochemical industries Our main focus is to give our customers gravimetrically produced, high precision calibration gas mixtures conforming to ISO 6142, along with a range of high purity gases and pressure control equipment, used for instrumental analysis and gas detection applications. AG Gases' senior management have many years experience in the European and International markets and now offer this knowledge to benefit Egyptian and North African customers.

    By AG Gases Ltd based in Stoke-on-Trent, UNITED KINGDOM.

  • Computerized instrumentation for the medical gas flow and scientific research

    Environics gas mixing, blending and dilution systems provide for precise mixing of gases for a wide variety of clinical applications. Our systems can produce gas concentrations from percent to ppb levels for single or multi-point calibration. The high accuracy of our mixers make them the units of choice for a wide variety of laboratory and research applications. For example, Environics Biological Atmosphere Incubation Mixers provide stable and accurate gas mixes for any laboratory or clinical need. You can generate the specific reduced oxygen environments needed for anerobes as well as the enriched oxygen environments needed in a variety of cellular, viral and high density culture applications. Systems can also be used to create a specific and stable gaseous environment in a clean room. In all cases, the Environics Atmosphere Mixers allow you to use less expensive single-gas cylinders or bulk tanks in place of a high number of expensive blended cylinders.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Ambient Monitor Gas Calibration with Ozone Generators

    EnvironicsĀ® Ambient Monitor Calibrator with Ozone Generators facilitate dynamic calibration of ambient air analyzers. These instruments automatically perform zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, O3, hydrocarbons and other gases of interest. All ozone generators are factory calibrated using a NIST traceable ozone standard. The Series 6100, Series 6103 and Series 9100 all meet or exceed U.S. Environmental Protection Agency requirements.

    By Environics, Inc. based in Tolland, CONNECTICUT (USA).

  • Premium

    Mercury monitoring for manual analysis of air traps

    The Tekran 2600 versatility is evident with the economical and convenient configuration for manual analysis of air samples collected on gold cartridges. Converting the instrument allows calibration by simple injection of gaseous Hg using the Tekran 2505. Once analyzed, the gold cartridges are immediately ready for redeployment.

    By Tekran Instruments Corporation based in Knoxville, TENNESSEE (USA).

  • Premium

    Application package Ash for analysing oxidic materials

    This application package is a `ready to go` calibration kit for xrf instruments. Fusion technology is ideal for analysing oxidic materials like ashes. It performs with the highest precision possible in xrf sample preparation. Primarily power stations and their control laboratories have to check the ash from the burning process of black and brown coal. Two standard DIN and ASTM methods describe the testing in detail. FLUXANA is able to deliver both methods ready from the bench.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

  • Premium

    Sub-ppm Oil in Water Testing

    InfraCal 2 is the newest addition to the worldwide-recognized Wilks InfraCal line of portable, filter-based infrared analyzers. It provides sub-ppm measurement capability, password protected calibrations and instrument settings, data storage and multiple calibrations, and a touch screen display for more user options. Ideal for measuring oil content levels in FRAC and produced water, fats, oil and grease (FOG) in wastewater, industrial and refinery wastewater effluents, cleaning of metal parats, drill cuttings, containment ponds and remediation sites.

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Premium

    Application package for analysing slags and filter dusts

    This application package is a `ready to go` calibration kit for xrf instruments. The analysis of slags and filter dusts in the metal industry delivers important information about the production process. FLUXANA has developed a fusion slag + filter dusts method which allows the direct analysis of most common slags and filter dusts. Elements of interest and calibrated concentration ranges can be selected individually by the customer.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

  • Premium

    Application package glass

    This application package is a 'ready to go' calibration kit for xrf instruments. In the glass industry, raw materials have to be analysed together with the quality control samples from production. FLUXANA has created two basic programs Raw Materials (CS-0022) and Glass (CS-0016) for these two purposes, which can be individually adapted by the customer. FLUXANA application packages include always the sample preparation method. All packages are running in our application laboratory. You are always free to send your samples for testing free of charge. If you combine our application packages with our sample preparation machines FLUXANA garanties the analytical performance of the package like a contract.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

  • Premium

    Testing Fume Hood Flow Dynamics using SF6 as a Tracer Gas

    A safe laboratory environment requires an effective method for clearing toxic material from fume hoods. Since all handling of toxic materials is completed in these hoods, it is critical to have a procedure to evaluate their operation to assure adequate protection for laboratory workers. The InfraRan Specific Vapor Analyzer, factory calibrated for SF6, is an ideal instrument for measuring fume hood efficiency in accordance with ASHRAE and other standards. Manufacturers identify the flow dynamics (factors that affect air flow in the hood and performance with air) using the ratings AM (as manufactured), AI (as installed), and AU (as used). A fume hood evaluation conducted under its operational environment is critical, as these tests will indicate any installation shortcomings as well as direct workers in proper laboratory hood techniques.

    By Spectro Scientific based in Chelmsford, MASSACHUSETTS (USA).

  • Premium

    Application package cement

    This application package is a `ready to go` calibration kit for xrf instruments. It contains all parts to perform a complete cement calibration: - Calibration set prepared from CRM as glass beads 40mm - Calibration work performed by FLUXANA expert 2 days on site - 2x drift monitors for xrf instrument - 2x control samples for validation each 10g powder for preparation on site - Flux FX-X100 FLUXANA application packages include always the sample preparation method. All packages are running in our application laboratory. You are always free to send your samples for testing free of charge. If you combine our application packages with our sample preparation machines FLUXANA garanties the analytical performance of the package like a contract.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

  • Premium

    Application package continous casting powder 'ready to go'

    This application package is a 'ready to go' calibration kit for xrf instruments. Together with the company Stollberg, FLUXANA has developed a fused bead method for the product control of continuous casting (CC) powders. The general idea was a universal program which covers a wide product range and that is also able to control the used raw materials. The result was two different application packages each with a set of standards and a set of control samples. - Calibration set continuous casting powders prepared from CRM as glass beads - Calibration set raw materials prepared from CRM as glass beads - Calibration work performed by FLUXANA expert 2 days on site - 2x drift monitors for xrf instrument - 2x control samples for validation each 10g powder for preparation on site - Flux FX-X100 FLUXANA application packages include always the sample preparation method. All packages are running in our application laboratory. You are always free to send your samples for testing free of charge.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

  • Dust monitoring of exhaust gases from manufacturing processes

    DynOptic dust monitors use the innovative Dynamic Detection Principle (DDP) to measure dust and particulate within exhaust gases from various manufacturing processes. DDP, or optical scintillation as it sometimes referred to, measures the dynamic fluctuation in light transmission as dust particles move through a light beam. This dynamic fluctuation derives from temporal distributions of the dust particles which attenuate the light beam. The more dust present in the exhaust, the greater the amplitude of these fluctuations. DDP instruments calculate the dynamic response, or the ratio of light variation to light intensity, which for particular applications, is proportional to dust concentration and when calibrated against standard reference measurements, this can be presented as a reading in mg/mĀ³.

    By DynOptic Systems Ltd based in Brackley, UNITED KINGDOM.