Only show results available in Virginia? Ok

chloride monitor Applications

  • Premium

    Measurement of vinyl chloride, acetaldehyde, methanol, and benzene in CO2 applicaitons for gas manufacturer & food and beverage industry

    The BevAlert Model 8900 provides direct measurement of Vinyl Chloride, Acetaldehyde, Methanol, and Benzene (VCAMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Environmental Water Analysis

    Now for the first time you can measure ion levels in drinking / tap water, rivers and lakes using one probe and one set of calibration solutions. We have probes specially tailored for environmental testing. Our Environmental probes measure Chloride, Ammonium and Nitrogen or we have a total nitrogen probe measuring Ammonium and Nitrogen. Each probe can be calibrated in our unique calibration solutions allowing you to calibrate all sensors simultaneously and take measurements in drinking or river water. Probes are also available in our standard four or six ion combinations and can be custom packaged upon request.

    By CleanGrow based in Blackpool, IRELAND.

  • Premium

    Measurement solution for liquid TiCl4 vanadium oxychloride monitor

    The chloride process of titanium dioxide (TiO2) pigment manufacture first converts titania-containing ores to TiCl4 via a carbochlorination reaction at a high temperature in a chlorinator in the presence of chlorine gas and petroleum coke added as a reductant.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • HCl Monitoring in Air

    Hydrogen chloride (HCl) is a colorless, sometimes slightly yellow, gas. It is an undesired environmental component that may be damaging to workers and the surroundings. Exposure limits have thus been established by industries to make sure that the workers operate in a safe environment. HCl monitoring is especially required for incinerators, coal-fired power plants, aluminum recycling and cement plants. Unisearch offers a reliable and easy-to-use HCl analyzer – the TDLAS-based LasIR system. Studies have shown that TDLAS equipment provides data that is more accurate than conventional gas monitoring equipment. When calibrated for HCl monitoring, TDLAS is able to detect this gas among other gases present in the area and provide continuous updates with regards to the changes in its concentration.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    Continuous emissions monitoring in cement kilns

    Various pollutants form in the cement manufacturing process, especially when alternative fuels and waste-derived fuels are used. Typically a cement kiln using these fuels is a required to monitor hydrogen chloride (HCl). Gasmet CEM II is EN 15267-3 approved for HCl measurement in 0 … 15 mg/Nm3 range.High process temperatures result in generation of more nitrogen oxides (NOx) than in typical municipal waste incineration.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Raw-gas monitoring for scrubber optimizing

    The consumption of scrubbing material in a scrubber is related to the mass flow of acid gases. Hydrogen chloride (HCl) and sulphur dioxide (SO2) are the major acid gases in an incinerator. By measuring the mass flow of SO2 and HCl in the raw gas going into the scrubber, it is possible to calculate the required quantity of scrubbing material.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Gas monitoring instruments and systems for stack testing according to EPA test method 320

    The United States Environmental Protection Agency (EPA) has two stack testing methods for FTIR gas analyzers. Method 320 is an FTIR method for measuring wide range of organic and inorganic pollutants. Method 321 is a specific version for measuring hydrogen chloride HCl at cement kilns producing Portland cement. These methods define a quality assurance and control processes for verifying the accuracy of the results. The requirements for analytical equipment and software are defined on 40 CFR Part 60 Appendix B Performance Specification 15. Gasmet™ Gas Analyzers and Calcmet™ software have been designed to take the requirements of the performance specification into account.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Moisture Monitoring for Refinery Recycle Gas & Plant Start-up

    Optimal performance of petrochemical reforming catalysts depends upon maintaining an optimal moisture / chloride ratio within the reforming reactor. When moisture and chloride are out of balance, catalysts suffer from higher deactivation rates and decreased yields. The cost of inadequately controlling the moisture / chloride ratio can be very high in terms of yield losses, off-spec product, increased catalyst regeneration , early catalyst replacement , processing upsets and / or increased downtime.

    By Moisture Control & Measurement Ltd based in Wetherby, UNITED KINGDOM.

  • Premium

    Gas Detection Solutions for Power Generation Industry

    Boreal possess an array of products for the power generation industry from emissions stack monitoring, boiler room monitoring, chloride leak detection, and ammonia slip in deNOX. Boreal’s products are tailor made for coal fired power plants, natural gas fired, and waste-to-energy. Whether gas detection is used for safety, process, or environmental reasons, Boreal has you covered.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you