Only show results in Massachusetts? Ok

chlorination monitoring Applications

  • Online monitoring solutions for determination of moisture in dry chlorine

    The purpose of determination of moisture in dry chlorine is threefold: prevent corrosion, prevent formation of ferric chloride and control the overall drying process. AppliTek offers two different solutions for determination of moisture: one traditional method by means of an amperometric phosphoric pentoxide (P2O5) electrochemical cell, or a more advanced technique based on tunable diode laser technology (TLDS). Both analyzer systems are installed in a compact protective corrosion resistant cabinet.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of impurities in dry chlorine

    The purpose of determining impurities in dry chlorine (after compression) is a quality control measure to avoid contamination and off-spec product batches. Alternatively, chlorine purity can also be determined by measuring absolute levels of chlorine in dry chlorine, by means of multi-wavelength UV analysis.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of hydrogen in dry chlorine

    Levels of hydrogen in dry chlorine are monitored in hydrochloric acid synthesis by means of AppliTek’s multi-wavelength IR analyzer system. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control the HCl synthesis. Each of these on-line analyzer systems has been selected to control a specific part of the burner, by using techniques such as multi-wavelength infrared, thermal...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the fast determination of hydrogen in wet chlorine

    The purpose of fast determination of hydrogen in wet chlorine is to set up an early warning system against high hydrogen levels, thereby protecting the chlorine production plant against hydrogen explosion incidents. The hydrogen concentration in wet chlorine is very critical, especially for membrane and diaphragm cell type production of chlorine. A breakthrough of hydrogen in the chlorine by membrane or diaphragm damage can occur within a few seconds. Depending on the concentration, a mixture of H2 and Cl2 gas...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of oxygen in dry chlorine

    Levels of oxygen in dry chlorine in hydrochloric acid synthesis are monitored by means of an on-line analyzer system that can be equipped with two different measuring technologies: Alternating Pressure Paramagnetic or Tunable Diode Laser (TDL) analyzer system.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the determination of chlorine in dry chlorine

    Levels of chlorine in dry chlorine in hydrochloric acid synthesis are monitored by means of AppliTek’s multi-wavelength UV analyzer system. Hydrochloric acid or HCl is one of the primary products of the chlor-alkali industry and commonly produced by the exothermic reaction of hydrogen and chlorine inside a burner. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control HCl...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for fast determination of hydrogen in dry chlorine

    Fast determination of hydrogen in dry chlorine provides an early warning system against elevated levels of hydrogen, thereby protecting the chlorine production plant against hydrogen explosion incidents. AppliTek’s analyzer system for fast determination of hydrogen in dry chlorine can be considered as Best Available Technology (BAT). However, it can never replace a system for determination of hydrogen in wet chlorine since it meets other needs in process control than those for wet chlorine. Even a tiny...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for fast determination of oxygen in wet chlorine

    The purpose of fast determination of oxygen in wet chlorine is twofold: verification and control of membrane oxygen permeation, as well as to keep control of the oxygen-chlorine-ethylene explosion triangle. The technology behind AppliTek’s analyzer system for the fast determination of oxygen in wet chlorine is qualified as Best Available Technology (BAT) as defined by US Clean Air Act and Clean Water Act, as well as European directive 96/61/EC.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for fast determination of oxygen in dry chlorine

    The purpose of fast determination of oxygen in dry chlorine is to verify the chlorine oxygen specifications, as well as to keep control of the oxygen-chlorine-ethylene explosion triangle. The technology behind AppliTek’s analyzer system for the fast determination of oxygen in wet chlorine is qualified as Best Available Technology (BAT) as defined by US Clean Air Act and Clean Water Act, as well as European directive 96/61/EC.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the determination of calcium and magnesium in hydrochloric acid

    The purpose of monitoring calcium and magnesium levels in hydrochloric acid is to control brine acidification in chlorine electrolysis, which can be precisely monitored by means of AppliTek’s UPA Universal Process Analyzer.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of residual chlorine in liquid phase EDC

    The purpose of determining residual chlorine in liquid EDC (ethylene dichloride) is to protect decrease risk of corrosion and damage to production units downstream. For all other analytical solutions in the chlorination process, please browse the On-line Analyzers Suite under Products & Solutions.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the determination of chlorinated organics in water

    Determining chlorinated organics in waste water of the oxychlorination process is for reasons of environmental compliance. The on-line analyzer system uses a scrubber system where a carrier flow is bubbling through the water. The vapor phase is measured by a Flame Ionization Detector (FID) and is a measure for chlorinated organics of the water.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the determination of chlorine in hydrochloric acid

    Chlorine levels in liquid hydrochloric acid (HCl) are precisely and safely monitored by means of AppliTek’s EZ-HCl process analyzer. On-line measurement of chlorine in liquid HCl guarantees the purity of the end product. An additional possible reason for the measurement is that chlorine is an indicator for the amount of excess hydrogen in the synthesis of hydrochloric acid.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the ethylene dichloride EDC-VCM industries

    As a specialist manufacturer of analytics, AppliTek is your one-stop-shop for state of the art analytical answers to the specific needs of the chemical industry. Ethylene dichloride (EDC) is a chemical liquid that is not found naturally in the environment, and classified as a hazardous chemical. Process control, as implemented by AppliTek, will significantly increase output, product quality, and decrease production hazards. Environmental compliance is another value-added benefit of the AppliTek technology.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Water quality solutions for disinfectant residual management sector

    The concept is simple enough but the reality of maintaining proper disinfectant residuals just isn`t always that easy. The water quality in your distribution system is constantly changing and constantly on the move. The disinfectant residual is up... now it`s down... hotspots here... no spots there... just like a game of disinfectant "whack-a-mole".

    By Medora Corporation based in Dickinson, NORTH DAKOTA (USA).

  • EDXRF spectrometers for petroleum & petrochemical

    Oil and fuel analysis - compliance with ASTM standard methods and other regulations. Xenemetrix state-of-the-art ED-XRF analyzers offer solutions for the Petroleum & Petrochemical analysis that comply with ASTM standards and regulations. Our superior solutions cover the full production process, starting from research & development up to process and quality control.

    By Xenemetrix Ltd. based in Migdal Haemek, ISRAEL.

  • Drinking water solutions for the TOC removal efficiency

    Problem: Organic matter (UV254/TOC) in drinking water can react with chlorine to form harmful disinfection by-products (DBPs). Some removal of TOC is achieved through the conventional drinking water treatment processes, while carbon absorption may be used to further enhance the removal of TOC prior to chlorine disinfection.

    By Real Tech Inc. based in Whitby, ONTARIO (CANADA).

  • EDXRF spectrometers for wood treatment industry

    Wood treatment used to protect lumber from fungi, insects, UV damage, water damage and general wear. When treating wood the proper balance of treatment solution must be monitored to ensure the highest quality while minimizing waste and excess cost due to treatment usage or product rejection.

    By Xenemetrix Ltd. based in Migdal Haemek, ISRAEL.

  • EDXRF spectrometers for food & beverage industry

    The Food & Beverage industry is a wide-scale and versatile industry, which is enforced by strict standards and regulations that makes it an ideal potential for the ED-XRF analytical systems. Using ED-XRF allows measuring a wide range of elements C (6)-Fm (100), at different concentration in almost all matrices - solids, powders and liquids.

    By Xenemetrix Ltd. based in Migdal Haemek, ISRAEL.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you