Only show results in Texas? Ok

chlorinator manufacturer Applications

  • Online monitoring solutions for determination of iron in hydrochloric acid

    Levels of iron in liquid hydrochloric acid (HCl) are precisely monitored by means of the EZ-HCl analyzer system. Iron oxides that dissolve in the HCl can lead to the formation of ferrous chloride (FeCl2) and compromised purity of the end product. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control the HCl synthesis. Each of these on-line analyzer systems has been selected to...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of hydrogen in dry chlorine

    Levels of hydrogen in dry chlorine are monitored in hydrochloric acid synthesis by means of AppliTek’s multi-wavelength IR analyzer system. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control the HCl synthesis. Each of these on-line analyzer systems has been selected to control a specific part of the burner, by using techniques such as multi-wavelength infrared, thermal...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the determination of chlorine in dry chlorine

    Levels of chlorine in dry chlorine in hydrochloric acid synthesis are monitored by means of AppliTek’s multi-wavelength UV analyzer system. Hydrochloric acid or HCl is one of the primary products of the chlor-alkali industry and commonly produced by the exothermic reaction of hydrogen and chlorine inside a burner. With increasing concerns over safety and efficiency in the chlorine manufacturing processes, AppliTek has investigated the use of proprietary on-line analyzer systems to monitor and control HCl...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Applications and Air Pollutants Removed in the Fiber Optic Industry

    Emissions of silicon tetrafluoride, hydrochloric acid, hydrofluoric acid, chlorine from silica glass manufacturing and coating. Emergency scrubbing. Drawing Tower off-gas emissions. High temperature emissions of particulate and acid gases from furnaces. Hydrochloric acid recovery and re-concentration.

    By Bionomic Industries Inc. based in Mahwah, NEW JERSEY (USA).

  • Premium

    Ultraviolet disinfection systems for the process water

    Water is often used as a product, or as part of the manufacturing process. In many industrial applications, processes are chemical (chlorine) intolerant, and UV is widely adopted. atg UV Technology engineers will be pleased to discuss solving disinfection problems with you. As well as a powerful disinfectant, UV is used to remove chlorine, chloramines, ozone, bromine, and a wide variety of contaminants from industrial process water. Within micro-electronics facilities for example, UV is used to remove Total...

    By atg UV Technology based in Wigan, UNITED KINGDOM.

  • On-site chlorine and sodium hypochlorite generation systems for Bleach manufacturing solutions

    Klorigen™ generators are ideally suited to commercial, municipal or industrial bleach manufacturing, as they are capable of generating the same ultra-pure sodium hypochlorite with the same high quality and 10% to 15% concentration levels as commercial bulk-delivered product.

    By Electrolytic Technologies Systems LLC based in North Miami Beach, FLORIDA (USA).

  • Online monitoring solutions for determination of hydrogen in hydrogen feed

    Levels of of hydrogen in the hydrogen feed of the HCl burner are reliably measured and controlled by means of AppliTek’s thermal conductivity analyzer system. The analyzer system is suited for use in hazardous environments and meets ATEX or NEC500 compliance standards.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of hydrogen in gas vent

    Levels of of hydrogen in the gas vent of the HCl burner can be measured by means of AppliTek’s thermal conductivity analyzer system. The analyzer system is suited for use in hazardous environments and meets ATEX or NEC500 compliance standards.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for the fast determination of hydrogen in wet chlorine

    The purpose of fast determination of hydrogen in wet chlorine is to set up an early warning system against high hydrogen levels, thereby protecting the chlorine production plant against hydrogen explosion incidents. The hydrogen concentration in wet chlorine is very critical, especially for membrane and diaphragm cell type production of chlorine. A breakthrough of hydrogen in the chlorine by membrane or diaphragm damage can occur within a few seconds. Depending on the concentration, a mixture of H2 and Cl2 gas...

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of oxygen in hydrogen feed

    AppliTek’s gas analyzer system allows to monitor and control precisely oxygen levels in the hydrogen feed of the HCl burner. The analyzer system can be equipped with either an electrochemical cell, by alternating Pressure Paramagnetic or with a Tunable Diode Laser (TDL).

    By AppliTek NV based in Nazareth, BELGIUM.

  • EDXRF spectrometers for plastic, polymers & rubber industry

    Plastics, polymers and rubber are combined with a variety of different additives in order to give them properties that are important for many different markets. These products are commonly analyzed as beads, which in their end form are pressed or molded into plaques.

    By Xenemetrix Ltd. based in Migdal Haemek, ISRAEL.

  • Online monitoring solutions for the determination of chlorine in hydrochloric acid

    Chlorine levels in liquid hydrochloric acid (HCl) are precisely and safely monitored by means of AppliTek’s EZ-HCl process analyzer. On-line measurement of chlorine in liquid HCl guarantees the purity of the end product. An additional possible reason for the measurement is that chlorine is an indicator for the amount of excess hydrogen in the synthesis of hydrochloric acid.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Online monitoring solutions for determination of oxygen in dry chlorine

    Levels of oxygen in dry chlorine in hydrochloric acid synthesis are monitored by means of an on-line analyzer system that can be equipped with two different measuring technologies: Alternating Pressure Paramagnetic or Tunable Diode Laser (TDL) analyzer system.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Brownfield Remediation

    Maximize ROI and Market Value of Brownfields Properties TerraTherm provides rapid, thorough, and predictable remediation of Brownfields property. Our in situ thermal processes can ensure rapid closure, avoid delays, eliminate uncertainty, avoid excavation, and optimize property value. In situ thermal remediation is a reliable, lower risk, and less disruptive way to achieve your remediation goals.

    By TerraTherm - a Cascade Company based in Gardner, MASSACHUSETTS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you