chromatography separation Applications

3 Results found
Only show results available in Virginia?
OK
  • Keyword: chromatography separation ×

Fast C1 to C5 - PetroAlert Series 9100

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The PetroAlert® Series 9100 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing a 30 second analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration, while maintaining C1-C2 separation at 200:1 concentration ratios.

Measurement of C1-C5 hydrocarbons for oil & gas exploration.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented. Then a third column is used in conjunction with a second 10-port valve for individual analysis of methane. C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis.

Related Terms for chromatography separation

Need help finding the right suppliers?

Let the XPRTs do the work for you