co2 sampling Applications

9 Results found
Only show results available in Virginia?
OK
  • Keyword: co2 sampling ×

Continuous emissions monitoring for CO2 capture

by Opsis AB     based in Furulund, SWEDEN

The process control of a CO2 capture plant needs good and reliable detection of gas phase NH3 and CO2. Measuring NH3 is a challenge due to the corrosive environment and high concentrations of NH3. Several places in the process needs to be monitored and to transport the sample is difficult. A large dynamic range is needed as the NH3 concentration can vary between 15% volume and a few mg/m3.

Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

by MOCON - Baseline     based in Lyons, COLORADO (USA)

The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

Gas monitoring instruments and systems for process NOx measurement

by Gasmet Technologies Oy     based in Helsinki, FINLAND

Nitric acid HNO3 is an important intermediate reagent for production of several important end products, such as fertilizers, explosives, dyestuffs/pigments, pesticides, pharmaceuticals, photographic materials, plastics, and synthetic fibers. At nitric acid manufacturing plants, the Gasmet™ FTIR Gas Analyzer can be used to measure several gaseous components from the process stream for purposes of process control. A single system can be used to measure the high levels of nitrogen monoxide NO and nitrogen dioxide NO2, as well as water vapor H2O, nitrous oxide N2O, carbon monoxide CO, carbon dioxide CO2 and ammonia NH3. The fixed installation products for these purposes are the Gasmet™ CEM II measurement system, and the Gasmet™ FCX Gas Analyzers, both of which utilize the FTIR measurement technique for simultaneous multicomponent analysis of the sample gas.

Gas Analysis Systems for Catalysis, Thermal Analysis, Fermentation and Bio Fuels

by Hiden Analytical     based in Warrington, UNITED KINGDOM

Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas and vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, and include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour and CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

Exhaust Gas Emissions

by Hiden Analytical     based in Warrington, UNITED KINGDOM

Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital ininformation for process development and process monitoring...

Microbial Studies

by Hiden Analytical     based in Warrington, UNITED KINGDOM

Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen & special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

Fragrance Fingerprinting

by Hiden Analytical     based in Warrington, UNITED KINGDOM

Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas & vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping & vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour and CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

Beverage Analysis

by Hiden Analytical     based in Warrington, UNITED KINGDOM

Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring

Gas control equipment for Life Science

by QCAL Messtechnik GmbH     based in Oberostendorf, GERMANY

QCAL introduces CO2Control for incubators and test chambers. These gas dosing units can be adapted to nearly every incubator or test chamber. The user can set a CO2 concentration up to 30% vol. CO2. The CO2Control measures the actual concentration and adds CO2 from a CO2 gas container. The NDIR CO2-sensor has an excellent long-term stability, which provides years of stable CO2 measurement. Also the other parts as the sample gas pump, valve and fittings are designed for maintenance-free use over years. Humidity effects are compensated upto 95% rh at 37°C, also temperature effects are automatically corrected upto 50°C. The other way to control gas atmospheres in any life science equipment is to use gas mixing units GMS_2CH ( 2 channels ) or GMS_3CH ( 3 channels ) for N2, O2 and CO2. They can match flowrates up to 80 liters per minute with a concentration range up to 100 Vol% O2 and/or CO2.

Need help finding the right suppliers?

Let the XPRTs do the work for you