Only show results available in Virginia? Ok

continuous monitoring instrument Applications

  • Ambient Continuous Metals Monitoring/ Fence Line Monitoring/ Source Identification

    The Xact® 625i combined with ADAPT software creates the industry's most powerful tool for high time resolution detection of airborne metals. The Xact® 625i measures trace metals at very low detection limits at time resolutions down to 15 minutes. The ADAPT package captures corresponding wind speed and wind direction data, then seamlessly integrates the measurements into wind regression analyses available at the touch of a button. This creates the most single most powerful fence line/ source identification instrument in the industry.

    By Cooper Environmental based in Beaverton, OREGON (USA).

  • Premium

    Gas monitoring instruments and systems for phosgene monitoring

    Phosgene COCl2 is a colorless gas. While it has been used as a Chemical Weapon Agent (CWA) in the past, currently this poisonous gas is also an important reagent in synthesis in the pharmaceutical and chemical industries. The plants using phosgene are typically equipped with gas sensors to detect leaks in the indoor ambient air. The critical situations arise when equipment in contact with the gas at the manufacturing facilities are serviced and maintained. As phosgene is very poisonous, even small gas pockets in serviced equipment may be dangerous to maintenance personnel. Gasmet™ FTIR Gas Analyzers are ideal tools to monitor point sources of phosgene. The measurement technology has high specificity, may be operated continuously, and has a fast response time.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas monitoring instruments and systems for anesthetic gases

    The anesthetic gases and vapors which leak into the indoor atmosphere during medical procedures are considered waste anesthetic gases (WAGs). The exposure is of relevance to thousands of professionals in hospitals, operating theaters, patient recovery rooms, dental offices, and veterinary clinics around the world, who may be continually exposed to the waste anesthetic gases during their workday. Typical gases of concern include nitrous oxide N2O and several halogenated compounds in vapor form, such as sevoflurane, isoflurane, enflurane, halothane, desflurane, and methoxyflurane. Short-term exposure to these gases may lead to several symptoms, such as dizziness, headaches, fatigue, nausea. Long-term exposure to some of the anesthetic agents may result in sterility, birth defects, cancer, and liver and kidney disease.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Gas monitoring instruments and systems for stack testing

    Several EU directives and national laws in European countries set requirements for continuous monitoring of flue gas emissions at power plants. Further requirements are set on the quality assurance of the installed measurement systems at the plants. The relevant standard in this regard is EN 14181:2004, the quality assurance of automated measuring systems. The standard dictates how to determine that the measurement systems installed for continuous emissions monitoring at a plant operate according to the directives and regulations set. Two major parts of this on-going quality assurance cycle are the QAL2 and AST procedures. A test laboratory performs tests on the systems on-site, and determines whether the systems fulfill the set requirements or not.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Dust monitoring and Sand Storm Monitoring

    The frequency and intensity of dust and sand storms in many parts of the world are steadily increasing due to droughts and climate change. The severity of such storms is anticipated to increase over the coming years. These dust storms may last hours or days and cause huge damage and imposed a heavy toll on society with its physical effects, such as visibility reduction, heavy winds, red sky, hailstone and severe lightning. Such Dust storms, have a negative impact on human health, and industrial products and activities. They reduce visibility, layer on skin and cloths, infiltrate buildings and find their way into food and drinking water leaving a permanent sandy feeling in your mouth. Traditional dust monitoring instruments whether they be purely filter based gravimetric samplers or continuous monitors utilising Tapered Element Oscillating Microbalance (TEOM) or Beta Attenuation (BAM) simply are unable to cope with the high dust loads created by these storms. The filters on these instruments are quickly clogged and no further measurements are possible until a service technician visits to replace filters and filter tapes. In dust storm events this is impossible. Therefore, over the past few years a need for alternate technology which are non filter based, can cope with extremely high dust loads, require minimal maintenance and can operate off solar power has been employed in regions such as the Gobi Desert of China for the continuous monitoring of dust storm events. These instruments have demonstrated that an instrument can measure dust storm events with maintenance performed only once every 12 months. That it is possible to communicate remotely and that these systems can not only provide an early warning for dust events but have the accuracy and sensitivity to be an extremely useful tool in gauging hourly changes of visibility. Infact such instruments have been utilised by a number of EPAs around the world, including all Australian EPAs for the purpose of measuring ambient visibility as well as providing an accurate indication of rising dust events.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Final effluent monitoring for wastewater treatment industry

    Industry and municipal waste-water (sewage) treatment plants have had to respond to environmental legislation such as the Urban Waste Water Directive, IPC, IPPC and now the EPR (Environmental Permitting Regulations). As successive legislation becomes more stringent, discharge consents have been progressively tightened, and the need for self-regulation has become more important. As a consequence, on-line instrumentation has been installed throughout waste-water industry to continuously to provide final effluent monitoring and perform water analysis for key consent parameters.

    By Pollution & Process Monitoring Ltd based in Sevenoaks, UNITED KINGDOM.

  • Monitoring industrial trade discharge for wastewater treatement industry

    Industry has had to respond to the requirements of progressive environmental legislation such as the Urban Waste Water Directive, IPC, IPPC and now the EPR (Environmental Permitting Regulations). As successive legislation becomes more stringent, discharge consents have been progressively tightened, and the need for self-regulation has become more important. As a consequence, on-line instrumentation has been installed throughout waste-water industry to continuously to provide trade discharge monitoring and perform continuous water analysis for key consent parameters.

    By Pollution & Process Monitoring Ltd based in Sevenoaks, UNITED KINGDOM.

  • Premium

    Application package continous casting powder 'ready to go'

    This application package is a 'ready to go' calibration kit for xrf instruments. Together with the company Stollberg, FLUXANA has developed a fused bead method for the product control of continuous casting (CC) powders. The general idea was a universal program which covers a wide product range and that is also able to control the used raw materials. The result was two different application packages each with a set of standards and a set of control samples. - Calibration set continuous casting powders prepared from CRM as glass beads - Calibration set raw materials prepared from CRM as glass beads - Calibration work performed by FLUXANA expert 2 days on site - 2x drift monitors for xrf instrument - 2x control samples for validation each 10g powder for preparation on site - Flux FX-X100 FLUXANA application packages include always the sample preparation method. All packages are running in our application laboratory. You are always free to send your samples for testing free of charge.

    By Fluxana GmbH Co. KG based in Bedburg-Hau, GERMANY.

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you