  • Premium

    Monitoring oil in power plant cooling water

    The Situation:

    A municipal power plant in the southern United States operates more than 10 stationary power plant engines capable of producing 52 megawatts of electric power. The plant is part of a larger statewide power grid system. Within the grid, the municipality brokers the purchase or sale of power hourly, based on the needs of municipality and the market rate for power on the grid system.

    By Turner Designs Hydrocarbon Instruments, Inc. based in Fresno, CALIFORNIA (USA).

  • Premium

    Monitoring once through cooling water

    The Situation

    Power plants and paper mills use service water loops and mill water loops respectively for the cooling of lubricating, hydraulic, turbine and transformer oil.  These cooling systems feature large, recirculating volumes of water which are treated with biocides, dispersants, and corrosion inhibitors. By comparison, refineries often use once through cooling water systems. The cooling water is taken from lakes, rivers, or the ocean and circulated once through the plant to cool processes. Large volumes of water are used to keep the return water temperature low enough to prevent adverse effects on the environment.

    By Turner Designs Hydrocarbon Instruments, Inc. based in Fresno, CALIFORNIA (USA).

  • Premium

    Monitoring of oil and petroleum hydrocarbons in cooling water

    By Lumex Instruments Group based in Mission, BRITISH COLUMBIA (CANADA).

  • Water quality monitoring systems for cooling water treatment industry

    A number of treatment products are often added to prevent corrosion, scaling and fouling. Coating of sensors and other effects of these products must be taken into account when selecting analyzers. Discharge monitoring needs special attention because zero measurements must be reliable over time with little maintenance.

    By SWAN Analytische Instrumente AG based in Hinwil, SWITZERLAND.

  • Premium

    Cooling Tower, algae and biofilm control

    “Efficiently lowers algae, biofilm formation, bacterial counts and chemical consumption.” When temperatures are high, for example in cooling towers, a matrix of different microorganisms such as bacteria, fungi, EPS and algae can grow very rapidly. The disadvantages of biofilm formation in cooling towers can be enormous. Therefore water used in cooling towers needs frequent treatment and chemical shocks to keep levels of micro-organisms to a minimum.

    By LG Sonic based in Zoetermeer, NETHERLANDS.

  • Premium

    Cooling & Drinkingwater: ATP monitoring of biomass growth in waters

    Monitoring Biomass in (Cooling Tower) Waters through ATP monitoring

    The TOXcontrol can be used for ATP monitoring. Currently our company is doing research for further developments for this application on the TOXcontrol.

    Monitoring the microbial population of cooling towers is necessary in order to maintain the proper operation of the system. Conventional methods for monitoring microbial populations work by culturing microorganisms, a time-consuming procedure that requires days or even weeks of incubation before the results are known. Biofouling can be well-advanced before treatment begins. In addition, it is believed that this technique does not detect the full range of microbial life present in cooling systems.

    By microLAN B.V. based in Waalwijk, NETHERLANDS.

  • Premium

    Monitoring of phenol in water

    The Situation

    A plant located in the eastern United States manufactures phenolic resin for applications in plastics molding. This plant uses well water for cooling its reaction process and then discharges the water into a local creek.

    By Turner Designs Hydrocarbon Instruments, Inc. based in Fresno, CALIFORNIA (USA).

  • Water Monitoring and Flow Measurement Systems for Hydrology

    In recent years acoustic flow measurement and flow metering has established itself as the standard method for measurement in many hydrological stations but is also used as the basis for various applications, for example for flood protection and flood forecasting. Ultrasonic flow meters are also used in hydro-engineering constructions. With this almost contact free technology data can be recorded continuously and it provides 24/7 monitoring. Such flow monitoring is particularly important in waterways used for shipping, transportation, irrigation, drainage and for cooling water extraction of power plants. A further important use of transit-time open channel flow meters is the transportation of water used for the supply of drinking water. Here the focus lies on detecting the flow rate of water loss at an early stage as it is sometimes difficult to detect small leakages.

    By HydroVision GmbH based in Kaufbeuren, GERMANY.

  • Premium

    Reduce biofilm formation

    In many industrial or professional applications where water is being stored, biofilm may grow. The growth of biofilm can damage the installations and reduce efficiency of the circuit. A biofilm can grow certain substrates which can be found in water. When temperatures are high, for example in cooling towers, a matrix of different micro- organisms such as bacteria, fungi, algae can grow very rapidly causing the formation of a biofilm on certain surfaces submerge in water. During the formation of this biofilm, certain micro organisms starts producing extra cellular polymeric substances (EPS) which reinforce the biofilm structure.

    By LG Sonic based in Zoetermeer, NETHERLANDS.

  • Premium

    Monitoring of leaks in heat exchangers

    The Situation

    A California refinery produces xylene for use as commercial product and a precursor for petrochemical manufacturing. A primary component to the production of xylene is the isolation and purification of the chemical from a complex mixture of petroleum hydrocarbons. Steam based heat exchangers are used to process the xylene. Inherent to the design and rough duty heat exchangers face during their operation, leaks can and do develop. When a heat exchanger leaks, xylene contaminates the steam and produces a number of problems ranging from loss of final product, contamination and fouling of steam transfer piping, and ultimately bio-fouling of cooling towers. Consistent and reliable monitoring for xylene or other petroleum hydrocarbons in cooling water or steam condensate can alleviate product loss and process equipment down time.

    By Turner Designs Hydrocarbon Instruments, Inc. based in Fresno, CALIFORNIA (USA).

  • Moisture Monitoring for Nuclear Reactors

    The Advanced Gas Cooled Reactor uses carbon dioxide gas to transfer heat from the nuclear fission core to the water boiler for steam generation. The moisture content needs to be monitored to avoid corrosion damage, and continuous moisture monitoring acts as a boiler leak detector or bulk moisture meter.

    By Moisture Control & Measurement Ltd based in Wetherby, UNITED KINGDOM.

  • Premium

    Monitoring of heat exchanger leaks in paper plant

    The Situation

    A paper plant in the Eastern United States uses 500 gallons per minute filtered pond water for cooling lubricating oil in its paper line. The resulting warmed water is diverted to an onsite pond. Because the water is used to cool lubricating oil, the plant could not reuse the water in its pulping process for fears of possible oil contamination of the paper pulp.

    By Turner Designs Hydrocarbon Instruments, Inc. based in Fresno, CALIFORNIA (USA).

  • Flow & Energy Management Solutions for plant & machine

    Spire Metering offers several solutions for leakage detection. The flowmeters are used to monitor cooling water in machining process. They are used also in liquid process control and leakage detection applications.

    By Spire Metering Technology based in Marlborough, MASSACHUSETTS (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you