Only show results available in Virginia? Ok

dissolved gas analysis Applications

  • Gas Permeation Analysis

    Dissolved Species Analysis Dissolved species analysis employing Hiden's high sensitivity membrane sampling technology for analysis of respiratory gases, hydrocarbons and sulphides is applied to a wide range of application areas including: Ecolological studies in sea water Bio fuel production from algae Pollution monitoring in river, estuary and reservoir waters Soil core analyses Fermentation

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Fermentation Off-Gas Analysis

    In pilot plant and production scale fermentors, information relating to yield of product is of high importance. Hiden's gas analysers are configured with a multiport Off-Gas analysis manifold enabling simultaneous sampling from multiple fermentors. Data is used for the calculation of the respiratory quotient, carbon production rate and oxygen uptake rate. The Off-Gas measurement provides the respiratory quotient in a time and space averaged form and with good response time. By comparison data from multiple dissolved species probes are more specific and can provide information about stirring efficiency, aeration and feed distribution within the fermentor. Dissolved gas measurements have the advantage of giving direct information on gas uptake and for dissolved output rates. Hiden Analyticaloffers systems with either Off-Gas or dissolved species inlets or both.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Fermentation Off-Gas Analysis

    In pilot plant and production scale fermentors, information relating to yield of product is of high importance. Hiden's gas analysers are configured with a multiport Off-Gas analysis manifold enabling simultaneous sampling from multiple fermentors. Data is used for the calculation of the respiratory quotient, carbon production rate and oxygen uptake rate. The Off-Gas measurement provides the respiratory quotient in a time and space averaged form and with good response time. By comparison data from multiple dissolved species probes are more specific and can provide information about stirring efficiency, aeration and feed distribution within the fermentor. Dissolved gas measurements have the advantage of giving direct information on gas uptake and for dissolved output rates. Hiden Analyticaloffers systems with either Off-Gas or dissolved species inlets or both.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Premium

    Gas analysis & monitoring system for soil degassing

    The migration of magma towards the surface in a volcano is usually accompanied by the release of gas that was previously dissolved in the magma itself. In an open conduit volcano, most of the gas escapes through the main conduits of the volcano and then through the craters. However, a significant proportion (approximately 10%) of the total quantity of gas can escape laterally through faults and fractures that are normally present in the flanks of a volcano. Therefore, increases in the amount of gas emitted usually indicate the initial stages of magmatic migration towards the surface.

    By ETG Risorse e Tecnologia based in Montiglio, ITALY.

  • Premium

    Analysis of VOC compounds in water by Purge & Trap or dynamic headspace

    Context & Challenges Volatile organic compounds (VOC) can be dissolved in water. Sometimes water is polluted and to study contamination of VOC in finished drinking water, VOC must be measured. Chromatotec® Solutions Chromatotec® has developed a specific system for the measurement of VOC in water: a Purge & Trap system, the airmoPURGE. The analyzer is coupled with a degasing system allowing the extraction of dissolved gases. The complete system is based on: - 502.2 method from US EPA – “Volatile organic compounds in water by purge and trap capillary column gas chromatography with photoionization and electrolytic conductivity detectors in series – Revision 2.1”. - 524.2 method from US EPA – “Measurement of purgeable organic compounds in water by capillary column gas chromatography/mass spectrometry – Revision 4.0”.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Environmental

    The analysis of volatile organic compounds at low concentration levels is fundamental to pollution monitoring and control. Hiden’s Hydramass spectrometer is a multi-stream gas analysis system for analysis of volatile organic compounds to the sub ppm level. In sea water the analysis of volatile organic compounds is used for both pollution monitoring and ecological studies. Hiden’s HPR 40 dissolved species analyser provides ppb sensitivity

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you