emissions analyzer Applications in Australasia

  • Traffic Emissions Monitoring

    Traffic, especially in urban locations, is one of the greatest contributors to air pollution. Traffic produces a variety of different pollutants that include particulates, NO2, NO, CO, hydrocarbons and in some cases SO2. The monitoring of roadside pollution can be challenging as often it is difficult to find suitable locations for large air quality monitoring systems and many sites that are available can be too far away to be representative of roadside air pollution. Roadside pollution concentrations can change...

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Gas monitoring instruments and systems for engine emissions measurements

    The exhaust gas from combustion engines is a complex mixture of gases and particulate matter. The composition of the gas may change rapidly. Multicomponent analysis of exhaust gases can be performed with a Gasmet™ FTIR Gas Analyzer with a response time (T90) of one second. The winning combination is the result using of a small volume gas sample cell, a powerful sample pump and a fast detector with liquid nitrogen cooling. The analyzer, sampling system and computer can be assembled on a cart for use in a...

    By Gasmet Technologies Oy Distributor in AUSTRALIA.

  • Premium

    Monitoring solutions for the continuous emissions monitoring

    Multi-gas Stack Analyzers for Continuous Emissions Monitoring. FTIR and UVDOAS Analyzer Models available for Insitu Probe, Internal or External Cells, or Cross Stack Sample Acquisition.

    By Cerex Monitoring Solutions, LLC. Office in Caringbah, AUSTRALIA.

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline Distributor in AUSTRALIA.

  • Premium

    Ambient air quality monitoring solutions for remote sensing of ship emissions

    New regulation forces ships to lower the emissions of SO2. Ships travelling in SECA areas has to either run on low sulphur fuel, or install SO2 scrubbers. To measure the SO2 emissions from a ship is not an easy task. OPSIS provides the Port Authorities with a unique measurement principle where the emissions from the ship is measured remotely. Light is passing the emissions and by analyzing the light, concentrations of SO2 can be measured.

    By Opsis AB Distributor in Knoxfield, AUSTRALIA.

  • Continuous Emissions Monitoring Calibration Systems (CEMCS)

    The Environics Series Continuous Emissions Monitoring Calibration Systems (CEMCS) have been used in CEM vans and laboratories for over twenty years. They meet or exceed the performance requirements of the United States EPA 40 CFR Part 51 Method 205 Appendix M. Our systems are custom built, computerized, mass flow controller based gas calibration systems which allow you to dilute a single high concentration cylinder of span gas to low levels for the calibration of gas analyzers.

    By Environics, Inc. Distributor in Caringbah, AUSTRALIA.

  • Gas detection analyzers for pollution control

    Government and environmental groups are forcing industries with medium to high VOC exhausts to reduce emissions by as much as 98%. Incineration using pollution control devices such as oxidizers and flare stacks is one way to bring the exhaust emissions in line with the regulations. Capturing and reusing solvent in a solvent recovery system is another way.

    By Control Instruments Corporation Distributor in Nottinghill, AUSTRALIA.

  • Premium

    Gas monitoring instruments and systems for flavoring agents

    Manufacturing of powdered and liquid flavorings and fragrances involves production phases where flavoring chemicals may be released into the ambient air breathed by workers. Exposure control by gas analyzers in the production rooms and laboratories is necessary to ensure that the Time-Weighted Average (TWA) concentrations do not exceed the maximum Permissible Emission Limit (PEL) values.

    By Gasmet Technologies Oy Distributor in AUSTRALIA.

  • Premium

    Gas monitoring instruments and systems for semiconductor manufacturing

    In the semiconductor manufacturing industry, various perfluorinated compounds (PFCs) are used. The emissions of the PFC compounds into the ambient air are reduced by scrubbing of the exhaust gases from the process. In this process, the Gasmet™ FTIR Gas Analyzers can be used to measure the emissions into the atmosphere and also monitor the efficiency of the scrubbers. Typically monitored PFCs in the exhaust gas include carbon tetrafluoride CF4, trifluoromethane CHF3, and hexafluoroethane C2F6.

    By Gasmet Technologies Oy Distributor in AUSTRALIA.

  • Premium

    Open path ambient air quality monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring.

    By Cerex Monitoring Solutions, LLC. Office in Caringbah, AUSTRALIA.

  • Premium

    Perimeter Ambient Air Monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring. Cerex multi-gas analyzers offer significant advantages over single gas analyzer arrays, electro-chemical sensor arrays and time integrated air sampling hardware

    By Cerex Monitoring Solutions, LLC. Office in Caringbah, AUSTRALIA.

  • Premium

    Gas Detection Solutions for Aluminium

    Primary aluminium smelting generates large amounts of hydrogen fluoride gas (HF). Worker safety and ambient air quality concerns require that HF be monitored at several locations in smelters. Traditionally, a variety of chemical sampling methods have been used for HF monitoring in and around smelters. However, these methods are labour intensive and require ongoing maintenance and consumables. During the past decade, laser based HF analyzers have been replacing the traditional methods. Laser analyzers are...

    By Boreal Laser Inc. Distributor in AUSTRALIA.

  • CO2 / CO Monitoring in Air

    CO (carbon monoxide) and CO2 (carbon dioxide) are generally measured to ensure process control. CO2 is the desired product and CO is undesired in combustion since it will explode in high enough concentrations. CO2 and CO concentrations can also be used to determine other process-specific efficiencies. Continuous emissions monitoring equipment that can be calibrated as a CO and CO2 analyzer is thereby essential for process control.

    By Unisearch Associates Inc. Distributor in AUSTRALIA.

  • O2 Monitoring in Air

    Oxygen (O2) is a colorless odorless gas, essential to all life on Earth but damaging in high concentrations. An O2 analyzer should thus be employed for safety management and air pollution prevention purposes. LasIR MP110 is perfect for continuous emission monitoring of O2. It is based on TDLAS technology and can be calibrated as an O2 analyzer, providing accurate and reliable measurements. It quickly responds to changes in compound concentration, thus providing continuous emission monitoring for the specified...

    By Unisearch Associates Inc. Distributor in AUSTRALIA.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you